• 제목/요약/키워드: Maximum efficiency

검색결과 4,330건 처리시간 0.026초

Energy Efficiency Optimization for multiuser OFDM-based Cognitive Heterogeneous networks

  • Ning, Bing;Zhang, Aihua;Hao, Wanming;Li, Jianjun;Yang, Shouyi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.2873-2892
    • /
    • 2019
  • Reducing the interference to the licensed mobile users and obtaining the energy efficiency are key issues in cognitive heterogeneous networks. A corresponding rate loss constraint is proposed to be used for the sensing-based spectrum sharing (SBSS) model in cognitive heterogeneous networks in this paper. Resource allocation optimization strategy is designed for the maximum energy efficiency under the proposed interference constraint together with average transmission power constraint. An efficiency algorithm is studied to maximize energy efficiency due to the nonconvex optimal problem. Furthermore, the relationship between the proposed protection criterion and the conventional interference constraint strategy under imperfect sensing condition for the SBSS model is also investigated, and we found that the conventional interference threshold can be regarded as the upper bound of the maximum rate loss that the primary user could tolerate. Simulation results have shown the effectiveness of the proposed protection criterion overcome the conventional interference power constraint.

계통연계형 태양광 인버터의 새로운 최대 전력점 추종과 태양전지의 전류리플 감소에 관한 연구 (A Study on the New Maximum Power Point Tracking and Current Ripple Reduction of Solar Cell for the Grid-connected PV Inverter)

  • 황의선;강문성;양오
    • 한국정보통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.1187-1195
    • /
    • 2013
  • 태양광 인버터는 항상 태양전지 어레이의 최대 전력을 추종하며 동작해야 한다. 또한 태양광 인버터는 폭넓은 태양전지의 최대 전력점 전압과 관계없이 최대 전력점을 추종해야 한다. 태양전지의 전류리플이 발생한다면 최대 전력점 추종 기능이 저하되고 일사량 변동이나 최대 전력점 변동 시 정상적으로 추종하기 어려워진다. 이러한 문제점을 해결하기 위해 본 논문에서는 고효율의 새로운 최대 전력점 추종 알고리즘과 태양전지의 전류리플 감소 알고리즘을 제안하였다. 4KW급 계통연계형 태양광 인버터에 적용하여 실험한 결과 최대 전력점 추종 효율이 99.97%, 인버터 출력 효율은 97.5%, 인버터 전류의 고조파 총 왜곡률은 1.05%로 우수한 성능을 보였다. 또한 0.5초 동안 일사량을 100% -> 10%, 10% -> 100%로 급격히 변동하였을 때에도 안정된 최대 전력점 추종이 가능함을 알 수 있었다.

전기자동차 구동용 영구자석형 동기전동기의 온라인 최적 효율제어 (On-Line Optimal Efficiency Control for Permanent Magnet Synchronous Motors Driving electric Vehicles)

  • Chun, Tae-Won
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.586-593
    • /
    • 1994
  • This paper suggests the algorithm for on-line efficiency control of permancent magnet synchronous motors driving the electric vehicles. The existance of unigue d-axis current is verified, which generates the maximum efficiency at operating points of motor. Using the Fibonacci search method, d-axis current converges to the minimization of inverter input power, and to prevent the variation of motor speed in process of the efficiency control, the voltage decoupled control strategy is introduced. Through the experiments, the effects of an efficiency control algorithm are verified.

방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해 (Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

Removal Efficiency of the Heavy Metals Zn(II), Pb(II) and Cd(II) by Saprolegnia delica and Trichoderma viride at Different pH Values and Temperature Degrees

  • Ali, Esam H.;Hashem, Mohamed
    • Mycobiology
    • /
    • 제35권3호
    • /
    • pp.135-144
    • /
    • 2007
  • The removal efficiency of the heavy metals Zn, Pb and Cd by the zoosporic fungal species Saprolegnia delica and the terrestrial fungus Trichoderma viride, isolated from polluted water drainages in the Delta of Nile in Egypt, as affected by various ranges of pH values and different temperature degrees, was extensively investigated. The maximum removal efficiency of S. delica for Zn(II) and Cd(II) was obtained at pH 8 and for Pb(II) was at pH 6 whilst the removal efficiency of T. viride was found to be optimum at pH 6 for the three applied heavy metals. Regardless the median lethal doses of the three heavy metals, Zn recorded the highest bioaccumulation potency by S. delica at all pH values except at pH 4, followed by Pb whereas Cd showed the lowest removal potency by the fungal species and vice versa in case of T. viride. The optimum bio-mass dry weight production by S. delica was found when the fungus was grown in the medium treated with the heavy metal Pb at pH 6, followed by Zn at pH 8 and Cd at pH 8. The optimum biomass dry weight yield by T. viride amended with Zn, Pb and Cd was obtained at pH 6 for the three heavy metals with the maximum value at Zn. The highest yield of biomass dry weight was found when T. viride treated with Cd at all different pH values followed by Pb whilst Zn output was the lowest and this result was reversed in case of S. delica. The maximum removal efficiency and the biomass dry weight production for the three tested heavy metals was obtained at the incubation temperature $20^{\circ}C$ in case of S. delica while it was $25^{\circ}C$ for T. viride. Incubation of T. viride at higher temperatures ($30^{\circ}C\;and\;35^{\circ}C$) enhanced the removal efficiency of Pb and Cd than low temperatures ($15^{\circ}C\;and\;20^{\circ}C$) and vice versa in case of Zn removal. At all tested incubation temperatures, the maximum yield of biomass dry weight was attained at Zn treatment by the two tested fungal species. The bioaccumulation potency of S. delica for Zn was higher than that for Pb at all temperature degrees of incubation and Cd bioaccumulation was the lowest whereas T. viride showed the highest removal efficiency for Pb followed by Cd and Zn was the minor of the heavy metals.

Evaluation of Pheromone Trap Settings for Managing Brinjal Shoot and Fruit Borer (Leucinodes orbonalis) in Brinjal

  • Rahman, Mizanur;Ali, Razzab;Islam, Mohammad Saiful;Wang, Myeong-Hyeon
    • 한국자원식물학회지
    • /
    • 제22권3호
    • /
    • pp.220-226
    • /
    • 2009
  • An experiment was conducted to find out among 9 trap settings the most appropriate site for trap placement in the Brinjal field based on Brinjal shoot and fruit borer trapping efficiency, shoot and fruit infestation, healthy and total fruit yield, and BCR. The efficiency of different trap setting positions varied significantly. Trapping efficiency observed the $T_{1}$ ensured the minimum shoot and fruit infestation 10.02% and 20.95%, respectively, minimum infested fruit yield (4.75 ton/ha), maximum healthy and total fruit yield (26.72 and 31.47 ton/ha) and the maximum BCR (1.70), which was followed by $T_{2}$ and $T_{4}$. The minimum trapping efficiency of $T_{9}$ treatment led the maximum shoot and fruit infestation 13.89 and 29.26%, respectively, maximum infested fruit yield (7.59 ton/ha), minimum healthy and total fruit yield (17.74 and 25.32 ton/ha) and the minimum BCR (1.00). A correlation between the number of BSFB adults trapped from the most efficient trap setting and the shoot and fruit infestation recorded and found a linear positive correlation between number of BSFB adults trapped and shoot infestation (r = 0.781) and fruit infestation (r = 0.810). The effect of pheromone trap positions observed in this study may be attributed to the easy accessibility of the lures and traps, when they are placed at the canopy.

기질 농도에 따른 미생물전기분해전지의 운전 특성 (Effect of substrate concentration on the operating characteristics of microbial electrolysis cells)

  • 서휘진;김재일;기서진;안용태
    • 유기물자원화
    • /
    • 제31권4호
    • /
    • pp.41-49
    • /
    • 2023
  • 본 연구는 주입 기질 농도에 따른 미생물전기분해전지 (Microbial electrolysis cell, MEC)의 운전성능을 조사하였다. 주입 기질 농도에 따른 MEC의 운전 성능을 비교하기 위해 6 개의 실험실 규모 MEC를 2, 4, 6 g/L Sodium acetate 조건으로 순서대로 주입 농도를 증가시켜 운전하였다. 전류밀도, 수소 생산량, SCOD 제거율을 분석하였고, 에너지 효율, cathodic hydrogen recovery를 계산하여 주입 기질 농도 별 MEC의 운전성능을 비교하였다. 체적 전류밀도는 4 g/L 조건에서 76.3 A/m3였고, 6 g/L로 주입 농도를 증가시켰을 때 19.0 A/m3로 4 g/L 주입 조건에 비해 75% 감소하였다. 수소 생산량은 4 g/L 주입 조건이 47.3 ± 16.8 mL로 가장 높았으나 수소 수율은 2 g/L 주입 조건이 1.1 L H2/g CODin로 가장 높았다. 에너지 효율 역시 2 g/L 조건에서 가장 높았고, 6 g/L 조건에서 가장 낮은 결과를 보여주었다. 최대 전기에너지 효율은 76.4%였으며, 2 g/L 조건에서 최대 전체에너지 효율은 39.7%였다. 그러나 기질 농도가 6 g/L로 증가하였을 때, 성능이 급격히 감소하였다. Cathodic hydrogen recovery 역시 에너지 효율과 유사한 경향을 보였으며, 가장 낮은 농도 조건에서 가장 높은 성능을 보여주었다. 따라서 MEC 운전에 있어서 SCOD 제거율뿐만 아니라 에너지 효율 등을 고려한 최적 운전을 위해서는 낮은 주입 농도 조건에서 운전하는 것이 바람직할 것으로 판단된다.

PMA-SynRM의 최대출력제어를 위한 시뮬레이션 연구 (A study of Maximum-Power Control Simulation for PMA-SynRM)

  • 편경범;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.103-105
    • /
    • 2009
  • This paper presents the maximum-power control simulation for PMA-SynRM. For maximum power, the maximum torque / current control method is conducted in constant-torque range and flux-weakening control method is conducted in constant-power range. For considering the nonlinear characteristics of inductance, machine constant is determined by FEM. Finally, experiment is conducted to calculate the efficiency.

  • PDF

격벽에 의한 조분리와 내부반송을 이용한 산화구 시설의 고도처리개선에 관한 연구 (A Study on the Treatment of Nutrients and Organic Carbon in Wastewater through Spatial Separation and Internal Recycling in a Modified Oxidation Ditch)

  • 이영신;오대민
    • 한국환경보건학회지
    • /
    • 제37권1호
    • /
    • pp.64-72
    • /
    • 2011
  • This study was performed to assess the removal efficiency on nitrogen, phosphorus and organic carbon in wastewater by spatial separation and internal recycling in a modified oxidation ditch process (modified OD). The performances of the modified OD were evaluated via laboratory-scale experiments. The process was operated at hydraulic retention times of 6-48 hours and solid retention times of 17-38 days. We found that organic carbon removal efficiency increased after the modified OD operation period. T-N removal efficiency remained stable; average T-N concentration of effluent was 8.02 mg/l after modified OD operation. In contrast, T-P concentration of effluent was over 1 mg/l. Nitrogen and phosphorus removal efficiency of modified OD at HRT 12 hr were 83.1% and 74.1%, respectively. Also, maximum efficiency was found at SRTs from 20 to 30 days. T-N removal efficiency was 83.1% at a C/N ratio from 3.0 to 3.5. However, T-N removal efficiency decreased at C/N ratios over 3.5. Also, T-P removal efficiency increased with HRT at C/P ratios in the same condition. Maximum efficiency was 74.1% at a C/P ratio from 25 to 28. T-N removal efficiency was 79.2% and T-P removal efficiency was 65.3% after M4 mode operation (added to the internal recycle line connected to the anoxic reactor). The modified OD with spatial separation and internal recycling developed in this study is, therefore, believed to be an improvement for solving problems in the nutrient removal technologies.

방전플라스마에 의한 NOx, SOx 분해시 메탄첨가의 영향 (Effect of CH4 Addition in Case of Decomposition of NOx, SOx by Discharge Plasma)

  • 강현춘;우인성;강안수
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.70-77
    • /
    • 2000
  • For hazardous air pollutants(HAP) such as NO, $NO_2$ and $SO_2$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(Surface induced discharge Plasma Chemical Processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min), initial concentrations(100~1,000 ppm) and additive($CH_4$) were measured and the products were analyzed with FT-IR. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3 % for NO, 84.7 % for $NO_2$ and 99 % far $SO_2$ were observed at the power consumptions of 19.8, 20 and 19W, respectively, and that decomposition efficiency decreased with increasing frequency above 20 kHz. And decomposition efficiency per unit power were 5.21 %/W for $SO_2$, 4.76 %/W for NO and 4.24 %/W for $NO_2$ and the highest decomposition efficiency was observed with $SO_2$. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. When the additive of $CH_4$ was used, decomposition efficiency was increased with increasing $CH_4$ content, and NO, $NO_2$ and $SO_2$ were almost completely decomposed with the efficiency of 99 %, 98 % and 99 %, respectively and therefore $CH_4$ was a good additive material. The optimum power for the maximum decomposition efficiency were 7.5 W for $SO_2$, 9.5 W for NO and 15.5 W for $NO_2$, respectively. Optimum power with the maximum decomposition efficiency were 9.5 W at 1,000 ppm of NO, 7~8 W at 100~500 ppm of NO and 15.5 W at all concentration range of $NO_2$ and 11.5 W at 1,000 ppm, 4.9 W at 500 ppm, 3.7 W at 100~300 ppm of $SO_2$ and power efficiency was best in these case.

  • PDF