• Title/Summary/Keyword: Maximum a Posterior

Search Result 264, Processing Time 0.033 seconds

A STUDY ON THE STRESS DISTRIBUTION OF CANTILEVER BRIDGE UNDER MAXIMUM BITE FORCE AND FUNCTIONAL BITE FORCE USING THREE DIMENSIONAL FINITE ELEMENT METHOD (최대교합 및 기능교합시 하악구치부 연장가공의치에 발생하는 응력에 대한 삼차원 유한요소법적 연구)

  • Park Chang-Keun;Lee Sun-Hyung;Chung Hun-Young;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.484-514
    • /
    • 1994
  • Cantilever bridge is widely used by mny clinicians, but its worst mechanical character, so called Class I lever system, makes dentists hesitate to restore the missing tooth with it. Therefore it is important to study stress of the cantilever bridge. In this study, two models of cantilever bridges that restores the missing mandibular second molar with two abutment teeth were constructed. One model was a type of cantilever bridge supported by a normal alveolar bone, the other one was supported by an alveolar bone resorbed to its 1/3 of root length. Maximum bite force(550N) and funtional maximum bite force(300N) were vertically applied to the distal end of the pontic, distal 1/3, and distal half of the pontic. And each force was also applied to centric occlusal contacts as a distributed force. Total 16 loading cases were compared and analyzed with 3-dimensional finite element method. The results were as follows: 1. The stress was concentrated on the joint of the pontic and the retainer, grooves, and distal cervical margin of the posterior retainer. 2. In case of maximum bite force(550N) at the end of the pontic, the risk of fracture at the joint of the pontic and the retainer was high. 3. In case of distributed force in centric occlusion and functional maximum bite force(300N), the stresses were less than the yield strength of the type VI gold for any loading cases. 4. In case of alveolar bone resorption, the occlusal force to the cantilever pontic caused more stress on the root apex and less stress on the alveolar crest region of the distal surface of the posterior abutment. 5. In case of alveolar bone resorption, the displacement was larger than that of normal alveolar bone in all loading cases.

  • PDF

Image Completion Using Hierarchical Priority Belief Propagation (Hierarchical Priority Belief Propagation 을 이용한 이미지 완성)

  • Kim, Moo-Sung;Kang, Hang-Bong
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.256-261
    • /
    • 2007
  • 본 논문은 이미지 완성(Image Completion)을 위한 근사적 에너지 최적화 알고리즘을 제안한다. 이미지 완성이란 이미지의 특정영역이 지워진 상태에서, 그 지워진 부분을 나머지 부분과 시각적으로 어울리도록 완성시키는 기법을 말한다. 본 논문에서 이미지 완성은 유사-확률적(pseudo-probabilistic) 시스템인 Markov Random Field로 모델링된다. MRF로 모델링된 이미지 완성 시스템에서 사후 확률(posterior probability)을 최대로 만드는 MAP(Maximum A Posterior) 문제는 결국 시스템의 전체 에너지를 낮추는 에너지 최적화 문제와 동일하다. 본 논문에서는 MRF의 최적화 알고리즘들 중에서 Belief Propagation 알고리즘을 이용한다. BP 알고리즘이 이미지 완성 분야에 적용될 때 다음 두 가지가 계산시간을 증가시키는 요인이 된다. 첫 번째는 완성시킬 영역이 넓어 MRF를 구성하는 정점의 수가 증가할 때이다. 두 번째는 비교할 후보 이미지 조각의 수가 증가할 때이다. 기존에 제안된 Priority-Belief Propagation 알고리즘은 우선순위가 높은 정점부터 메시지를 전파하고 불필요한 후보 이미지 조각의 수를 제거함으로써 이를 해결하였다. 하지만 우선순위를 정점에 할당하기 위한 최초 메시지 전파의 경우 Belief Propagation의 단점은 그대로 남아있다. 이를 개선하기 위해 본 논문에서는 이미지 완성을 위한 MRF 모델을 피라미드 구조와 같이 층위로 나누어 정점의 수를 줄이고, 계층적으로 메시지를 전파하여 시스템의 적합성(fitness)을 정교화 해나가는 Hierarchical Priority Belief Propagation 알고리즘을 제안한다.

  • PDF

A FINITE ELEMENT ANALYSIS OF THE DISPLACEMENT AND STRESS DISTRIBUTION OF HUMAN DRY MANDIBLE DURING THE MANDIBULAR FIRST MOLAR CERVICAL TRACTION (유한요소법에 의한 하악제 1 대구치의 Cervical Traction의 효과에 관한 역학적 연구)

  • Ahn, Eui-Young;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.45-59
    • /
    • 1989
  • This study was undertaken to analyze the displacement and stress distribution in the mandible according to the pulling directions during mandibular first molar cervical traction after mandibular second molar extraction. The 3-dimensional finite element method(FEM) was used for a mathematical model composed of 594 elements and 1019 nodes. An orthodontic force, 450 gm, was applied to the each mandibular first molar in parallel, and below the occlusal plane by $7^{\circ}\;and\;25^{\circ}$ and meet the midsagittal plane by $40^{\circ}$ toward posterior direction. The results were as follows: 1. Mandibular teeth were displaced in more downward, posterior and lateral direction. Especially high stress was noted in case of parallel pull than in case of below the occlusal plane by $7^{\circ}\;and\;25^{\circ}$. 2. Mandibular first molar was moved bodily. 3. Generally, alveolar bone, mandibular body, ascending ramus and mandibular angle portion were displaced in downward, posterior and lateral direction. But coronoid process was displaced in downward, forward and lateral direction, and anterior and inner middle portion of condyle head and neck were displaced in downward, forward and medial direction, and posterior and outer middle portion of condyle head and neck were displaced in upward, forward and medial direction. 4. Maximum stress was observed at the condyle head and neck portion. With steeper direction of force, condyle head and neck showed more stress than parallel relation to the occlusal plane.

  • PDF

A Finite Element Analysis of Stress Distribution in the Temporomandibular Joints Following the Teeth Loss (치아결손이 측두하악관절의 응력분포에 미치는 영향에 관한 유한요소법적 분석)

  • Woo-Cheon Kee;Jae-Kap Choi;Jae-Hyun Sung
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.33-72
    • /
    • 1991
  • The purpose of this study was to investigate the stress distribution and the displacement in the temporomandibular joints following the teeth loss patterns. The three dimensional finite element method was used for a mathematical model. The finite element model was composed of 1,632 elements and 2,411 nodes in the mandible with articular disc and mandibular fossa of the temporal bone. The masseter, the temporal and the internal pterygoid muscle forces were applied at each insertion site, bisecting point of gonion and antegonion, tip of the coronoid process, and gonion at the ration of 2:2:1 respectively. The directions of muscles force were obtained from frontal and lateral cephalometric tracings using bony landmarks of the skull. The results were as follows : 1. In control model, the minimum principal stresses were concentrated on the region of anterosuperior part of the condyle head and articular disc, and maximum principal stresses on the anterior part of the condyle head and posterolateral part of the articular disc. 2. In case of unilateral teeth loss, the greater principal stress appeared at the teeth loss side and the principal stresses increased at the teeth loss side as the number of the posterior teeth loss went up. 3. In case of bilateral teeth loss, the principal stresses were greater than those of the control model and as the number of the posterior teeth loss increased, the grater principal stresses on the temporomandibular joints appeared at the both side. 4. When the posterior teeth existed bilateral, the principal stress patterns were similar to those of the control model. 5. The displacement ws directed mainly upward and backward in the upper part of the temporomandibular joints and upward and forward in the largest part of the condyle head. The displacement increased as the number of the posterior teeth loss went up.

  • PDF

Comparison of Difference of the Gluteus Medius Muscle Fiber Thickness during maximum muscle contraction between Chronic Low Back Pain with Gluteus Medius Weakness and Healthy Subject (중둔근 약화를 가진 만성요통환자와 건강한 대상자간 중둔근 최대 근수축 시 근섬유별 두께 비교)

  • Lee, Sang-Wk;Kim, Suhn-Yeop;Yang, Jin-Mo;Park, Seong-Doo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2015
  • PURPOSE: The aim of this study is to compare changes in the thickness of the gluteus medius muscle fiber between chronic low back pain(clbp) with gluteus medius weakness and healthy subject. METHODS: Ultrasound imaging was used to measure in the thickness of each fiber of the gluteus medius muscle based on maximal muscle contraction during abduction motion of the hip joint in a healthy group (11 subjects) and a chronic CLBP group (21 subjects). An independent t-test was performed to analyze the difference of thickness in each fiber of the gluteus medius muscle and the rate of changes in the fibers in the two groups. RESULTS: The fiber thickness changes in the gluteus medius muscle were significantly lower for the posterior fiber in the CLBP group compared to the healthy group (p<0.01). The changes in rate of difference of thickness the posterior part of the gluteus medius muscle was significantly lower in the CLBP group than in the healthy group (p<0.05). CONCLUSION: The findings of this study CLBP patients with weakness of the gluteus medius muscle that lower for the posterior fiber's difference of thickness and rate of change in the CLBP group compared to the healthy group. Indicate that rehabilitation of CLBP patients with weakness of the gluteus medius muscle should consider the functions of posterior fiber of the gluteus medius muscle.

Finite Element Modeling and Nonlinear Analysis of Lumbosacrum Including Partial Ilium and Iliolumbar Ligaments (부분 장골과 장요추 인대를 포함한 요추 천추골의 유한 요소 모델링 및 비선형 해석)

  • Ha, S.K.;Lim, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.397-409
    • /
    • 2007
  • Owing to needs of biomechanical comprehension and analysis to obtain various medical treatment designs which are related with the spine in order to cure and diagnose LBP patients, the FE modeling and nonlinear analysis of lumbosacrum including a partial ilium and iliolumbar ligaments, were carried out. First, we investigated whether the geometrical configuration of vertebrae displayed by DICOM slice files is regular and normal condition. After constructing spinal vertebrae including a partial ilium, a sacrum and five lumbars (from L1 to L5)with anatomical shape reconstructed using softwares such as image modeler and CAD modeler, we added iliolumbar ligaments, lumbar ligaments, discs and facet joints, etc.. And also, we assigned material property and discretized the model using proper finite element types, thus it was completely modeled through the above procedure. For the verification of each segment, average sagittal ROM, average coronal ROM and average transversal ROM under various loading conditions(${\pm}10Nm$), average vertical displacement under compression(400N), ALL(Anterior Longitudinal Ligament) and PLL(Posterior Longitudinal Ligament) force at L12 level, strains of seven ligaments on sagittal plane at L45 level and maximal strain of disc fibers according to various loading conditions at L45 level, etc., they were compared with experimental results. For the verification of multilevel-lumbosacrum spine including partial ilium and iliolumbar ligaments, the cases with and without iliolumbar ligaments were compared with ROM of experiment. The results were obtained from analysis of the verified FE model as follows: I) Iliolumbar ligaments played a stabilizing role as mainly posterior iliolumbar ligaments under flexion and as both posterior and anterior iliolumbar ligaments of one side under lateral bending. 2) The iliolumbar ligaments decreased total ROM of 1-8% in total model according to various motion conditions, which changed facet contact forces of L5S level by approximately 0.8-1.4 times and disc forces of L5S level by approximately 0.8-1.5 times more than casewithout ilioligaments, under various loading conditions. 3) The force of lower discs such as L45 and L5S was bigger than upper discs under flexion, left and right bending and left and right twisting, except extension. 4) It was predicted that strains of posterior ligaments among iliolumbar ligaments would produce the maximum 16% under flexion and the maximum 10% under twisting. 5) It's expected that this present model applies to the development and design of artificial disc, since it was comparatively in agreement with the experimental datum.

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

RELIABILITY ESTIMATION OF A MIXTURE EXPONENTIAL MODEL USIGN GIBBS SAMPLER

  • Kim, Hee-Cheul;Kim, Pyong-Koo
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.2
    • /
    • pp.661-668
    • /
    • 1999
  • Reliability estimation using Gibbs sampler considered for modeling mixture exponential reliability problems. Gibbs sampler is developed to compute the features of the posterior distribution. Bayesian estimation of complicated functions requires simpler esti-mation techniques due to the mathematical difficulties involved in the Bayes approach. The Maximum likelihood estimator and the Gibbs estimator of reliability of the system are derived. By simula-tion risk behaviors of derived estimators are compared. model de-termination based on relative error is considered. A numerical study with a simulated data set is provided.

Flow Visualizations and Laser Doppler Velocity Measurements in a Fontan Connection

  • Kim, Young-H.;Yoganathan, Ajit P.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.111-114
    • /
    • 1994
  • Three component velocity measurements with a refractive index-matching technique was used to investigate the flow characteristics in the atrio-pulmomnary (AP) Fontan connection under the steady flow condition. A strong swirl was observed in the extra-cardiac conduit and the main pulmonary artery (MPA). Maximum velocity magnitude in the MPA was about 0.8 m/s near the posterior wall at 6 liter/min. Swirling motion of the flow as well as geometric abnormalities of the connection are important factors in energy loss across Fontan connections.

  • PDF

QRS Detection based on Maximum A-Posterior Estimation (MAP Estimation을 이용한 QRS Detection)

  • 정희교;신건수
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.205-214
    • /
    • 1987
  • In this paper, a mathmatical model for the purpose of QRS detection is considered in the case of the occurence of nonoverlappjng pulse-shaped waveforms corrupted with white noise. The number of waveform, the arrival times, amplitudes, and widths of QRS complexes are regarded as random variables. The joint MAP estimation of all the unknown Quantities consists of linear filtering followed by an optimization procedure. Because the optimization procedure is time-consuming, this procedure is modified so that a threshold test is obtained.

  • PDF