• Title/Summary/Keyword: Maximum Material Condition

Search Result 445, Processing Time 0.029 seconds

STRESS DISTRIBUTION OF PERIODONTALLY INVOLVED TEETH RESTORED WITH VAR10US POSTS -THREE-DIMENSIONAL FINITE ELEMENT STUDY- (치주 지지가 감소된 소구치에서 포스트가 치근 응력 분포에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Jeong, Hye-Jin;Yoo, Jae-Heung;Oh, Nam-Sik;Kim, Han-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.567-578
    • /
    • 2007
  • Statement of problem: The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. As periodontal treatment was developed, there are many cases that periodontally involved teeth used in prosthetic treatment. Purpose: The purpose of this study was to analyze the stress distribution in the dentin and post structures by the various post materials and the amount of remaining alveolar bone height. Material and method: The 3-dimensional finite element models of mandible 1st premolars were divided into six types according to the various amount of remaining alveolar bone and post type. All types were modeled using equal length, diameter and shape of the post. Three types of post and core materials were used: prefabricated titaniumpost and amalgam core, prefabricated stainless steel post and amalgam core, and cast gold post and core. 300 Newton force was applied to functional cusp of mandible 1st premolar. Results: The results were as follows: First, there was no apparent difference in the pattern of stress distribution according to the alveolar bone condition concentrate on the post middle area. Second, there was difference in pattern of stress distribution according to the core materials, gold post and core generated same than amalgam core. Third, there was no apparent difference in the pattern of stress distribution within the dentin according to the post and core materials. But a cast gold post and core generated the lowest maximum stress value, a stainless steel post generated the highest maximum stress value. Fourth, in the reduced alveolar bone model, maximum stress value is 1.5 times than that of the normal alveolar bone model. Conclusion: Within the limitations of this study, to provide minimal stress to the root with alveolar bone reduced, the post length may be as long as apical seal was not destroyed. To prevent fracture of tooth, it is rational to use gold alloy which material was good for stress distribution for post materials.

Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis (전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석)

  • Park, Jun-Sung;Lee, Sang Hyun;Song, Chanhee;Ro, Jung Hoon;Lee, Chiseung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.

A study on the effects of polymer core gate sizes on thickness shrinkage rate (폴리머코어 게이트 크기 변화가 두께 방향 수축률에 미치는 영향에 대한 연구)

  • Choi, Han-Sol;Jeong, Eui-Chul;Park, Jun-Soo;Kim, Mi-Ae;Chae, Bo-Hye;Kim, Sang-Yun;Kim, Yong-Dae;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the variation of the shrinkage in the thickness direction of the molded parts according to the gate size of the polymer core fabricated through the 3D printer using the SLS method was studied. The polymer cores are laser sintered and the powder material is nylon base PA2200. The polymer cores have lower heat transfer rate and rigidity than the metal core due to the characteristics of the material. Therefore, the injection molding test conditions are set to minimize the deformation of the core during the injection process. The resin used in the injection molding test is a PP material. The packing condition was set to 80, 90 and 100% of the maximum injection pressure for each gate size. The runner diameter used was ∅3mm, and the gates were fabricated in semicircle shapes with cross sections 1, 2, and 3 ㎟, respectively. Thickness measurement was performed for 10 points at 2.5 mm intervals from the point 2.5 mm away from the gate, and the shrinkage to thickness was measured for each point. The shrinkage rate according to the gate size tends to decrease as the cross-sectional area decreases as the maximum injection pressure increases. The average thickness shrinkage rate was close to 0% when the packing pressure was 90% for the gate area of 1mm2. When the holding pressure was set to 100%, the shrinkage was found to decrease by 3% from the standard dimension due to the over-packing phenomenon. Therefore, the smaller the gate, the more closely the molded dimensions can be molded due to the high pressure generation. It was confirmed that precise packing process control is necessary because over-packing phenomenon may occur.

A Study on the Effect of Moisture Content of Wood upon the Absorption on Zinc Chloride Solution (침지처리법에(浸漬處理法)있어서 목재함수량(木材含水量)이 염화아연 흡수율(吸收率)에 미치는 영향(影響))

  • Shim, Chong-Supp;Shin, Dong-So
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.133-134
    • /
    • 1982
  • This experiment has been made to investigate the absorption of watersoluble zinc chloride by Pinus densiflora S. et Z. at different moisture content, under soaking process, to decide the optimum content condition for the maximum absorption of zinc chloride by the wood tested and to investigate the concentration of zinc chloride affecting each moisture content of wood. Material was cut in the Dept. of Forest, College of Agr. S.N.U. Suwon, Korea. Sample was divided into sap and heartwood group and cut $2{\times}2{\times}2\;cm$ in size, having exact three dimensions, using the part of D.B.H. The numbers of sample were 20 pieces for each moisture content condition for both sap and heartwood. Especially, the samples were protected from exposure to keep moisture content in green condition. The ranges of moisture content tested were as the table 3 and 4. The conclusions were as follows: 1. With 3% zinc chloride solution, the rate of absorption decreased with the time increased, if the air seasoned Korean red pine (Pinus densiflora S. et Z.) was treated in steeping process. Initial absorption for 30 minutes was more than 50% of total absorpon for 24 hours. 2. Rate of absorption was same under the green condition, while rate of absorption under the moisture content 7 to 30% varied. 3. Although it was not quite proportional change in the absorption with the difference of moisture content, the great change in the absorption occured by seasoning. With exception sap green condition, sapwood twice more permeable than the heartwood in the oven dried condition and it has been observed the nearly same amount of absorption at the moisture content of 7%, 10% and 15% respectively in heartwood. 4. It was better from water in wood from view-point of absorption of zinc chloride solution, but it was difficult practically to obtain the smallest moisture content, and then it was decided that values of allowable moisture content, on the basis of mean absorption, were 15% to 20% in the sapwood, and in the heartwood, 10% to 15%. The mean absorption for each moisture content in the sap and the heartwood were as following. 5. In general, the concentration of zinc chloride after steeping was nearly same between moisture content and sap and heartwood respectively.

  • PDF

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

Optimization of the Backfill Materials for Underground Power Cables considering Thermal Resistivity Characteristics (II) (열저항 특성을 고려한 지중송전관로 되메움재의 최적화(II))

  • Kim, You-Seong;Cho, Dae-Seong;Park, Young-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.123-130
    • /
    • 2011
  • In the precedent study it was presented that the comparison of thermal resistivity using various backfill materials including river sand regarding water content, dry unit weight and particle size distribution. Based on the precedent study, this study focused on developing the optimized backfill material that would improve the power transfer capability and minimize the thermal runaway due to an increase of power transmission capacity of underground power cables. When raw materials, such as river sand, recycled sand, crush rock and stone powder, are used for a backfill material, they has not efficient thermal resistivity around underground power cables. Thus, laboratory tests are performed by mixing Fly-ash, slag and floc with them, and then it is found that the optimized backfill material are required proper water content and maximum density. Through various experimental test, when coarse material, crush rock, is mixed with recycled sand, stone powder, slag or floc for a dense material, the thermal resistivity of it has $50^{\circ}C$-cm/Watt at optimum moisture content, and the increase of thermal resistivity does not happen in dry condition. The result of experiments approach the optimization of the backfill materials for underground power cables.

Case Study on Local Scour Evaluation of Il-San Bridge (일산대교 교각세굴 평가 사례 연구)

  • Lee, Ju-Hyung;Kwak, Ki-Seok;Park, Jae-Hyeon;Chung, Moon-Kyung;Yoon, Hyun-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.667-676
    • /
    • 2005
  • In this research, the reasonable local scour estimates considered conditions of the bed material and the flow was accomplished on two piers P14 and P17 of Il-san bridge. Especially, the Il-san bridge was located on the lower Han-river where is influenced by the tides of In-chon, and it has hydraulic condition that can cause the bridge piers local scour because of tides at ordinary times, as well as a flood. Therefore, the local scour depth has been presented influenced by the maximum velocity of the flow when a flood after construction and the tides on construction on the basis of the standards of river design and road design, furthermore, the results was made a comparative analysis. According to the results, the local scour depth on the basis of the standards of river design was higher than it on the basis of the standards of road design(SRICOS), and the local scour depth influenced by the maximum velocity of the flow when a flood after construction was determined the final local scour depth of P14 and P17 at the Il-san bridge. It was ascertained that the local scour depth did not exceed the inserted depth of bridge foundation.

  • PDF

The Stress Distribution Property on the Customized Ankle Foot Orthoses During the Gait Period (보행주기에 따른 맞춤형 단하지보조기의 응력분포 특성)

  • Choi, Young-Chul;Rhee, Kun-Min;Choi, Hwa-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.165-175
    • /
    • 2008
  • An ankle-foot orthosis(AFO) is a brace for persons with gait disabilities to support or replace the function of ankle joint. Ankle-foot orthoses(AFO's) are usually prescribed to alleviate the drop-foot by constraining the excessive plantar flexion. The shape and the strength of the AFO are often based on 'trial and error' due to a lack of knowledge of the stress distribution in the AFO. In this study, an improved stress-freezing method was proposed to measure the stress distribution characteristics in the AFO. As a result, a photoelastic material with low freezing temperature was developed to measure the stresses under a person's direct contact loading condition. The three-dimensional stress-1rozen photoelastic models of AFO's for five stages of stance phase such as heel contact, foot flat, mid stance, heel off, and toe off were produced. The results of photoelastic analysis revealed that the stresses developed in the AFO were varied considerably from tensile to compressive or vice versa, during walking. At the posterior part of ankle joint in the AFO, the maximum compressive stress of 1.81MPa was observed in the mid stance, and the maximum tensile stress of 0.74MPa was observed during heel contact. The overall stress levels in the AFO's were low in the toe off phase. The results suggested that the posterior part of ankle joint might be the most fragile part in the AFO.

A Study on the 1-Way FSI Analysis for Shutter of Side Jet Thruster (측추력기 Shutter의 단방향 유체-구조 연성해석에 관한 연구)

  • Ko, Jun Bok;Seo, Min Kyo;Lee, Kyeong Ho;Baek, Ki Bong;Cho, Seung Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1359-1365
    • /
    • 2014
  • In this study, 1-way fluid structure interaction analysis(FSI) for the shutter, component of side jet thruster was performed to evaluate the safety. Driving torque to open nozzle, thermal and high pressure load of hot gas was applied to shutter. Thus, the shutter must be designed to endure this load during combustion. We carried out computational fluid dynamics analysis to obtain the pressure, temperature, and heat transfer coefficient of hot gas of side jet thruster. We then used the data as the load condition for a thermal structural analysis using a mapping method. The locations with the maximum stress and temperature distributions were found. We compared the maximum stress with the tensile stress of shutter material according to temperature to evaluate the safety. We also analyzed the radial deformation of the shutter to set the proper interface gap with the side jet thruster parts.

Influence of structure coupling effect on damping coefficient of offshore wind turbine blades

  • Zhang, Jianping;Gong, Zhen;Li, Haolin;Wang, Mingqiang;Zhang, Zhiwei;Shi, Fengfeng
    • Wind and Structures
    • /
    • v.29 no.6
    • /
    • pp.431-440
    • /
    • 2019
  • The aim of this study was to explore the influence of structure coupling effect on structural damping of blade based on the blade vibration characteristic. For this purpose, the scaled blade model of NREL 5 MW offshore wind turbine was processed and employed in the wind tunnel test to validate the reliability of theoretical and numerical models. The attenuation curves of maximum displacement and the varying curves of equivalent damping coefficient of the blade under the rated condition were respectively compared and analyzed by constructing single blade model and whole machine model. The attenuation law of blade dynamic response was obtained and the structure coupling effect was proved to exert a significant influence on the equivalent damping coefficient. The results indicate that the attenuation trend of the maximum displacement response curve of the single blade varies more obviously with the increase of elastic modulus as compared to that under the structure coupling effect. In contrast to the single blade model, the varying curve of equivalent damping coefficient with the period is relatively steep for the whole machine model. The findings are of great significance to guide the structure design and material selection for wind turbine blades.