• Title/Summary/Keyword: Maximum Demand

Search Result 744, Processing Time 0.029 seconds

Effect of Anchorage on Strength of Precast R/C Beam-Column Joints

  • Kim, Kwangyeon
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 2000
  • Recently, there is a great demand for precast reinforced concrete (RC) construction methods on the purpose of simplicity in construction. Nishimatsu Construction Company has developed a construction method with precast reinforced concrete members in medium-rise building. In this construction method, how to joint precast members, especially the anchorage of the main bar of beam, is important problem. In this study, the structural performance of exterior joints with precast members was investigated. The parameters of the test specimens are anchorage type of the main bar of beam (U-shape anchorage or anchorage plate) and the ratio of the column axial force to the column strength. Specimens J-3 and J-4 used U-shape anchorage and the ratio of the column axial force of specimen J-4 was higher. On the other hand, specimens J-5 and J-6 used anchorage plate, and the anchorage lengths are 15d and 18d, respectively. Experimental results are summarized as follows; 1) For the joints with beam flexural failure mode, it was found that the maximum strength of specimen with anchorage plate is equal to or larger than that of specimen with conventional U-shaped anchorage if the anchorage length of more than 15d would be ensured, 2) Each specimen shows stable hysteretic curves and there were no notable effects on the hysteretic characteristics and the maximum strength caused by the anchorage method of beam main bar and the difference of column axial stress level.

  • PDF

Performance Analysis of Adaptive Collaborative Communications in Wireless Networks (무선네트워크에서 적응형 협력통신의 성능 분석에 관한 연구)

  • Khuong Ho Van;Kong Hyung-Yun;Jeong Hwi-Jae
    • The KIPS Transactions:PartC
    • /
    • v.13C no.6 s.109
    • /
    • pp.749-756
    • /
    • 2006
  • Broadcast nature of wireless medium and path-loss reduction create a favourable condition for collaborative communications (CC) among single-antenna users to gain the powerful benefits of multi-antenna system without the demand for physical arrays. This paper proposes a CC strategy adapting to the propagation environment changes by optimizing the transmit signal amplification factors to simplify the structure of maximum likelihood (ML) detector and to obtain the minimum error probability as well. The closed-form BER expression was also derived and compared to the simulation results to evaluate the performance of the suggested solution. A variety of numerical results revealed the cooperation significantly outperforms non-cooperative counterpart under flat Rayleigh fading channel plus AWGN (Additive White Gaussian Noise).

Textile dye wastewater treatment using coriolus versicolor

  • Sathian, S.;Radha, G.;Priya, V. Shanmuga;Rajasimman, M.;Karthikeyan, C.
    • Advances in environmental research
    • /
    • v.1 no.2
    • /
    • pp.153-166
    • /
    • 2012
  • Decolourization potential of white rot fungal organism, coriolus versicolor, was investigated in a batch reactor, for textile dye industry wastewater. The influence of process parameters like pH, temperature, agitation speed and dye wastewater concentration on the decolourization of textile dye wastewater was examined by using Response surface methodology (RSM). The maximum decolourization was attained at: pH- 6.8, temperature - $27.9^{\circ}C$, agitation speed - 160 rpm and dye wastewater concentration - 1:2. From the analysis of variance (ANOVA) results it was found that, the linear effect of agitation speed and dye wastewater concentration were significant for the decolourization of textile dye wastewater. At these optimized condition, the maximum decolourization and chemical oxygen demand (COD) reduction was found to be 64.4% and 79.8% respectively. Various external carbon sources were tried to enhance the decolourization of textile dye wastewater. It was observed that the addition of carbon source enhances the decolourization of textile dye wastewater. Kinetics of textile dye degradation process was studied by first order and diffusional model. From the results it was found that the degradation follows first order model with $R^2$ value of 0.9430.

A Study on Application of the Photo Detector for Electromagnetic Fuel Injection System of DI Diesel Engine (직분식 디젤기관 전자분사계의 광검출기 적용에 관한 연구)

  • Ra, Jin-Hong;Ahn, Soo-Kil
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.38-46
    • /
    • 1999
  • Increasing stringent emissions legislation and requirement of more effective energy used for diesel engine demand the fine control of the fuel injection system. Recently, the electromagnetic fuel injection control system for diesel engine is tried to realize the optimum diesel combustion by the feel back sensing as optical signal of combustion flame. The photo detectors were made for the feed back signal of electromagnetic fuel injection control for small DI diesel engine. Their abilities to detect defining combustion events were examined. By evaluating test results, it was shown that the wider acceptable optical range design of optical probe window face, and selection of installation position and installation method of detector were important point for improving sensing ability. The detector was shown to detect start and end of diffused combustion and maximum point of flame intensity impossible for pressure sensor, and also shown that the maximum point of flame intensity was 75% of accumulated heat release point within the experimental conditions.

  • PDF

Leaf Temperature Characteristics being Affected by Light Regimes (광조건에 따른 식물의 엽온 특성)

  • Park, Yong-Mok
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1599-1605
    • /
    • 2011
  • To evaluate heat environment surrounding plants diurnal change of leaf temperature in the broad-leaved deciduous and evergreen trees was measured with microclimatic environmental factors including global solar radiation, and upward and downward long wave radiation. Maximum daily solar radiation was 961.2 and 976.3 w/$m^2$ in August 9 and 23, respectively. Upward long wave radiation was slightly higher than downward long wave radiation, showing 404.2 w/$m^2$ in August 9 and 394.5 w/$m^2$ in August 23. In addition, daily maximum vapor pressure deficit was 5.42 and 6.84 kPa in August 9 and 23, respectively, indicating high evaporative demand. Quercus glauca and Acer mono was differently responded to changing light regimes. On August 9, leaf temperature at the top-positioned leaves of Acer plants was higher than air temperature as well as those of Quercus plants in the morning. This indicates that stomata in Acer plants were closed by heat stress or water stress in the morning, while Quercus plant maintained active transpiration by opening stomata. These results indicated that improved light regimes such as gap opening in the closed forest may not always affect positively in the physiology of understory plants.

Photosynthetic Characteristics of Anabaena flos-aquae Growing on Various Inorganic Nitrogen Sources (무기질소원의 종류에 따른 염조류 Anabaena flos-aquae 광합성의 특성)

  • 맹주선
    • Journal of Plant Biology
    • /
    • v.25 no.4
    • /
    • pp.153-160
    • /
    • 1982
  • The kinetics of $^{14}C$ fixation have been investigated in Anabaena flos-aquae growing on ${NH}_4+$,$NO_3-$ and $NO_2-N$ in batch cultures. Growth rate was highest with ${NH}_4+$, followed by $NO_2-$ and finally $NO_2$. The compensation intensity($I_0$) and the half-saturation irradiance($K_1$) with $K_1$ were higher than with other N sources, but the maximum C fixation rate($P_{max}$) was lower. The ($P_{max}$)/$K_1$ ratio, which is analogous to quantum efficiency at low irradiance ranges, was also lower with $N_2$. All these parameters except $K_1$ decrease with culture age, or decreasing growth rate. Since $^{14}C$ uptake measures net photosynthesis, the higher values of $I_0$ and $K_1$, and the low values of $P_{max}$/$K_1$ ratio with $N_2$ appear to be related to the high energy demand of $N_2$fixation. They may also be related to the lox maximum growth rate with $NO_2-N$.

  • PDF

제약폐수 활성슬러지 공정에서 DO농도에 따른 미생물의 활성 변화 측정

  • Mun, Sun-Sik;Lee, Sang-Hun;Sin, Jong-Cheol;Choe, Gwang-Geun;Lee, Sang-Hun;Mun, Heung-Man;Lee, Jin-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.355-358
    • /
    • 2002
  • In this study, we have tried to find the maximum microbial efficiency at the various dissolved oxygen (DO) concentration conditions in the treatment of pharmaceutical wastewater. Experiments of activated sludge process were performed to examine the relation between microbial activity and DO concentration in a continuous bioreactor. The reduction rate of COD (chemical oxygen demand) was low at the DO concentration between 0 ppm and 1.0 ppm, but it went higher and showed maximum between 1.5 ppm and 3.0 ppm. Then the COD reduction rate was quickly decreased above the DO concentration of 3.0 ppm.

  • PDF

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • Kim, Min-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.9
    • /
    • pp.172-178
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state -of-the-art reaches the region of sub-nanometers. So far, the demand has been met by increasing the clock speed that drives the electronics involved fur the phase measurement of the Doppler shift, but its further advance is being hampered by the technological limit of modem electronics. To cope with the problem, in this investigation, we propose a new scheme of phase -measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with a stable reference signal generated from a special phase- locked-loop. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special form of frequency up-down counting technique is combined with the super-heterodyning. This allows performing required phase unwrapping simply by using programmable digital gates without 2n ambiguities up to the maximum velocity guaranteed by the original beat frequency.

A Study on the Assessment of a Reasonable Transformer Capacity by the Improvement of Diversity Factor (부등률 적용 개선을 통한 변압기의 적정용량 산정에 관한 연구)

  • Seo, Seung-Kwan;Oh, Yong-Taek;Kim, Se-Dong;Shin, Wha-Young;Yoo, Sang-Bong;Lee, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.15-20
    • /
    • 2010
  • This paper shows a reasonable diversity factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 20 Lease Apartment. In this paper, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried out by the linear and nonlinear regression analysis. The standards of demand, diversity, and load density are necessary to create the design of a transformer capacity that is seldom presented in terms for academic study.

Design Considerations for a Distributed Generation System Using a Voltage-Controlled Voltage Source Inverter

  • Ko, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong;Naya, Chemmangot V.;won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.643-653
    • /
    • 2009
  • Voltage-controlled voltage source inverter (VCVSI) based distributed generation systems (DGS) using renewable energy sources (RES) is becoming increasingly popular as grid support systems in both remote isolated grids as well as end of rural distribution lines. In VCVSI based DGS for load voltage stabilization, the power angle between the VCVSI output voltage and the grid is an important design parameter because it affects not only the power flow and the power factor of the grid but also the capacity of the grid, the sizing of the decoupling inductor and the VCVSI. In this paper, the steady state modeling and analysis in terms of power flow and power demand of the each component in the system at the different values of maximum power angle is presented. System design considerations are examined for various load and grid conditions. Experimental results conducted on a I KVA VCVSI based DGS prove the analysis and simulation results.