• Title/Summary/Keyword: Maxillofacial region

Search Result 697, Processing Time 0.026 seconds

Can a spontaneous smile invalidate facial identification by photo-anthropometry?

  • Pinto, Paulo Henrique Viana;Rodrigues, Caio Henrique Pinke;Rozatto, Juliana Rodrigues;da Silva, Ana Maria Bettoni Rodrigues;Bruni, Aline Thais;da Silva, Marco Antonio Moreira Rodrigues;da Silva, Ricardo Henrique Alves
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.279-290
    • /
    • 2021
  • Purpose: Using images in the facial image comparison process poses a challenge for forensic experts due to limitations such as the presence of facial expressions. The aims of this study were to analyze how morphometric changes in the face during a spontaneous smile influence the facial image comparison process and to evaluate the reproducibility of measurements obtained by digital stereophotogrammetry in these situations. Materials and Methods: Three examiners used digital stereophotogrammetry to obtain 3-dimensional images of the faces of 10 female participants(aged between 23 and 45 years). Photographs of the participants' faces were captured with their faces at rest (group 1) and with a spontaneous smile (group 2), resulting in a total of 60 3-dimensional images. The digital stereophotogrammetry device obtained the images with a 3.5-ms capture time, which prevented undesirable movements of the participants. Linear measurements between facial landmarks were made, in units of millimeters, and the data were subjected to multivariate and univariate statistical analyses using Pirouette® version 4.5 (InfoMetrix Inc., Woodinville, WA, USA) and Microsoft Excel® (Microsoft Corp., Redmond, WA, USA), respectively. Results: The measurements that most strongly influenced the separation of the groups were related to the labial/buccal region. In general, the data showed low standard deviations, which differed by less than 10% from the measured mean values, demonstrating that the digital stereophotogrammetry technique was reproducible. Conclusion: The impact of spontaneous smiles on the facial image comparison process should be considered, and digital stereophotogrammetry provided good reproducibility.

Novel Discovery of LINE-1 in a Korean Individual by a Target Enrichment Method

  • Shin, Wonseok;Mun, Seyoung;Kim, Junse;Lee, Wooseok;Park, Dong-Guk;Choi, Seungkyu;Lee, Tae Yoon;Cha, Seunghee;Han, Kyudong
    • Molecules and Cells
    • /
    • v.42 no.1
    • /
    • pp.87-95
    • /
    • 2019
  • Long interspersed element-1 (LINE-1 or L1) is an autonomous retrotransposon, which is capable of inserting into a new region of genome. Previous studies have reported that these elements lead to genomic variations and altered functions by affecting gene expression and genetic networks. Mounting evidence strongly indicates that genetic diseases or various cancers can occur as a result of retrotransposition events that involve L1s. Therefore, the development of methodologies to study the structural variations and interpersonal insertion polymorphisms by L1 element-associated changes in an individual genome is invaluable. In this study, we applied a systematic approach to identify human-specific L1s (i.e., L1Hs) through the bioinformatics analysis of high-throughput next-generation sequencing data. We identified 525 candidates that could be inferred to carry non-reference L1Hs in a Korean individual genome (KPGP9). Among them, we randomly selected 40 candidates and validated that approximately 92.5% of non-reference L1Hs were inserted into a KPGP9 genome. In addition, unlike conventional methods, our relatively simple and expedited approach was highly reproducible in confirming the L1 insertions. Taken together, our findings strongly support that the identification of non-reference L1Hs by our novel target enrichment method demonstrates its future application to genomic variation studies on the risk of cancer and genetic disorders.

Directions of mandibular canal displacement in ameloblastoma: A computed tomography mirrored-method analysis

  • Evangelista, Karine;Cardoso, Lincoln;Toledo, Italo;Gasperini, Giovanni;Valladares-Neto, Jose;Cevidanes, Lucia Helena Soares;de Oliveira Ruellas, Antonio Carlos;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.17-25
    • /
    • 2021
  • Purpose: This study was performed to investigate mandibular canal displacement in patients with ameloblastoma using a 3-dimensional mirrored-model analysis. Materials and Methods: The sample consisted of computed tomographic scans of patients with ameloblastoma (n=10) and healthy controls (n=20). The amount of mandibular canal asymmetry was recorded as a continuous variable, while the buccolingual (yaw) and supero-inferior (pitch) directions of displacement were classified as categorical variables. The t-test for independent samples and the Fisher exact test were used to compare groups in terms of differences between sides and the presence of asymmetric inclinations, respectively (P<0.05). Results: The length of the mandibular canal was similar on both sides in both groups. The ameloblastoma group presented more lateral (2.40±4.16 mm) and inferior (-1.97±1.92 mm) positions of the mental foramen, and a more buccal (1.09±2.75 mm) position of the middle canal point on the lesion side. Displacement of the mandibular canal tended to be found in the anterior region in patients with ameloblastoma, occurring toward the buccal and inferior directions in 60% and 70% of ameloblastoma patients, respectively. Conclusion: Mandibular canal displacement due to ameloblastoma could be detected by this superimposed mirrored method, and displacement was more prevalent toward the inferior and buccal directions. This displacement affected the mental foramen position, but did not lead to a change in the length of the mandibular canal. The control group presented no mandibular canal displacement.

Assessment of the dimensions of the pterygoid hamulus for establishing age- and sex-specific reference standards using cone-beam computed tomography

  • Mehra, Archana;Karjodkar, Freny R.;Sansare, Kaustubh;Kapoor, Ruchika;Tambawala, Shahnaz;Saxena, Vasu Siddhartha
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.49-54
    • /
    • 2021
  • Purpose: This study was conducted to establish age- and sex-specific reference standards for pterygoid hamulus(PH) dimensions using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 1,000 patients(493 males and 507 females) were retrospectively assessed in coronal sections for length and width measurements of the PH by 3 investigators. The study data were divided into 3 age groups(group 1: <20 years, group 2: 20-50 years, group 3: >50 years). Length and width were compared using one-way analysis of variance and the t-test for age and sex, respectively. Results: The length of the PH on the right side significantly increased from group 1 (6.11±1.47mm), through group 2 (6.65±1.67 mm) to group 3 (6.99±1.79 mm) and on the left side from group 2 (6.58±1.63) to group 3 (6.98±1.70). The width of the PH significantly decreased from group 1 (1.81±0.39 mm) to group 2 (1.61±0.39 mm) on the right side, and similarly from 1.87±0.36mm to 1.67±0.37mm on the left side. PH length (7.18±1.81mm on the right side and 7.10±1.72 mm on the left side) and width (1.68±0.38 mm on the right side and 1.74±0.36 mm on the left side) were significantly greater in males than in females. Conclusion: The length of the PH increased with age, whereas width first decreased and then increased. Length and width measurements were significantly higher in males than in females. These findings will aid in the diagnosis of untraceable pain in the oropharyngeal region related to altered PH morphology.

Fractal dimension analysis on CBCT scans for detecting low bone mineral density in postmenopausal women

  • Carvalho, Bruno Fontenele;de Castro, Julia Goncalves Koehne;de Melo, Nilce Santos;Figueiredo, Paulo Tadeu de Souza;Moreira-Mesquita, Carla Ruffeil;de Paula, Ana Patricia;Sindeaux, Rafael;Leite, Andre Ferreira
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.53-60
    • /
    • 2022
  • Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

Ectopic teeth with disparate migration: A literature review and new case series

  • Pallak Arora ;Madhu K. Nair ;Hui Liang ;Paras B. Patel ;John M. Wright;Mehrnaz Tahmasbi-Arashlow
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.229-238
    • /
    • 2023
  • Purpose: Ectopic eruption can be defined as the emergence of a tooth in an abnormal location, where the tooth does not follow its typical eruption pathway. While ectopic eruption within the dentate region is well-documented in the literature, ectopic eruption in non-dentate regions is relatively rare. This study aimed to report 6 cases of ectopic teeth and present a systematic review of the English-language literature on ectopic teeth, emphasizing demographic characteristics, radiographic features, potential complications, and treatment options. Materials and Methods: A literature search was conducted using the PubMed, Medline, Web of Science, and Cochrane databases. The demographic data and radiographic findings of patients presenting with ectopic teeth were recorded. Results: The literature review yielded 61 cases of ectopic teeth, with patients ranging in age from 3 to 74 years. The findings from these previously reported cases demonstrated that the most common location for ectopic teeth was the maxillary sinus, which is consistent with this case series. The Pearson chi-square test was performed to evaluate the correlation between age and location of ectopic teeth, and the results were found to be statistically significant (P<0.05). However, no statistically significant relationship was observed between sex and the location of ectopic teeth. Conclusion: The distinct features of these cases warrant reporting. This study presents the first case of supernumerary teeth in the condyle without any associated pathosis. Another notable characteristic is the pre-eruptive resorption of 2 inverted supernumerary teeth ectopically located in the palate, which predisposes to sinus opacification.

Role of the Gastrocnemius Musculocutaneous with a Propeller Style Skin Flap in Knee Region Reconstruction: Indications and Pitfalls

  • Gianluca Sapino;Rik Osinga;Michele Maruccia;Martino Guiotto;Martin Clauss;Olivier Borens;David Guillier;Pietro Giovanni di Summa
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.593-600
    • /
    • 2023
  • Background Soft tissue reconstruction around the knee area is still an open question, particularly in persistent infections and multiple reoperations scenario. Flap coverage should guarantee jointmobility and protection, even when foreign materials are implanted. The chimeric harvesting of the musculocutaneous gastrocnemius flap, based on the sural artery perforators, can extend its applicability in soft tissue reconstruction of the upper leg, overcoming the drawbacks of the alternative pedicled flaps. Methods A multicenter retrospective study was conducted enrolling patients who underwent to a pedicled, chimeric gastrocnemius musculocutaneous-medial sural artery perforator (GM-MSAP) or lateral sural artery perforator (GM-LSAP) flap for knee coverage in total knee arthroplasty (TKA) recurrent infections and oncological or traumatic defects of the upper leg from 2018 to 2021. Outcomes evaluated were the successful soft tissue reconstruction and flap complications. Surgical timing, reconstruction planning, technique, and rehabilitation protocols were discussed. Results Twenty-one patients were included in the study. Nineteen GM-MSAPs and 2 GM-LSAPs were performed (soft tissue reconstruction in infected TKA [12], in infected hardware [4], and in oncological patients [5]). Donor site was closed primarily in 9 cases, whereas a skin graft was required in 12. Flap wound dehiscence (1), distal flap necrosis (1), distal necrosis of the skin paddle (1), and donor site infection (1) were the encountered complications. Flap reraise associated to implant exchange or extensive debridement was successful without requiring any further flap surgery. Conclusion The propeller-perforator GM-MSAP offers qualitative defect coverage and easiness of multiple flap reraise due to skin availability and its laxity.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

MORPHOLOGY OF THE TERMINAL ARBORS FROM THE MASSETERIC MUSCLE SPINDLE AFFERENTS IN THE TRIGEMINAL MOTOR NUCLEUS (삼차신경 운동핵에서 교근 근방추 구심성 신경섬유 종말지의 미세구조)

  • Lee, Kyung-Woo;Bae, Yong-Chul;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.321-347
    • /
    • 1994
  • Muscle spindle afferents from masseter muscle were labelled by the intra-axonal HRP injection and were processed for light microscopic reconstruction. Regions containing terminal arbors scattered in the central portion of the masseteric motor neuron pool (type I a) and those restricted to 2-3 small portion of it (type II) were selected and processed for electronmicroscopic analysis with serial sections. The shape of the labelled boutons was dome or elongated shape. Scalloped or glomerulus shape with peripherial indentation containing pre or postsynaptic neuronal propiles, which is occasionally found in the trigeminal main sensory nucleus and spinal dorsal horn, was not observed. Both type Ia and type II boutons had pale axoplasm and contained clear, spherical vesicles of uniform size(dia : 49-52nm) and occasionally large dense cored vesicles(dia : 87-118nm). The synaptic vesicles were evenly distributed throughout the boutons although there was a slight tendency of vesicles to accumulate at the presynaptic site. The average of short and long diameter(short D. + long D./2) of type I a bouton was smaller than that of type II bouton. All the labelled boutons, which showed prominent postsynaptic density, large synaptic area and multiple synaptic contact, made asymmetrical synaptic contact with postsynaptic neuronal propiles. Most of the type Ia and type II boutons made synaptic contact with only one neuronal propile and boutons which shows synaptic contact or more neuronal propiles was not observed. Most of the type Ia boutons(87.2%) were presynaptic to the soma or proximal dendrite and a few remainder(12.8%) made synaptic contact with dendritic shaft or distal dendrite. In contrast, majority of type II boutons showed synaptic contact with dendritic shaft and remainder with soma or proximal dendrite. In conclusion, terminal boutons which participate in the excitatory monosynaptic jaw jerk reflex made synaptic contact with more proximal region of the neuron, and showed very simple synaptic connection, compared with those from the primary afferenst in the other region of the central nervous system such as spinal dorsal horn and trigeminal main sensory nucleus which assumed to be responsible for the mediating pain, tactile sensation, sensory processing or sensory discrimination.

  • PDF