• 제목/요약/키워드: MaxRMS

검색결과 22건 처리시간 0.019초

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • 제7권5호
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.32-42
    • /
    • 2019
  • Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and pelvis. One plan for each treatment site was selected from real VMAT cases and contours were mapped into the computational human phantom where the same plan as real VMAT plan was created and called plan-class specific reference (pcsr) QA plan. We delivered this pcsr QA plan on a daily basis over the full research period and tracked how much MLC movement and dosimetric error occurred in regular delivery. Several real patients under treatments were also tracked to test the usefulness of pcsr QA through comparisons between them. We used dynalog file viewer (DFV) and Dynalog file to analyze position and speed of individual MLC leaf. The gamma pass rate from portal dosimetry for different gamma criteria was analyzed to evaluate analyze dosimetric accuracy. Results and Discussion: The maxRMS of MLC position error for all plans were all within the tolerance limit of < 0.35 cm and the positional variation of maxPEs for both pcsr and real plans were observed very stable over the research session. Daily variations of maxRMS of MLC speed error and gamma pass rate for real VMAT plans were observed very comparable to those in their pcsr plans in good acceptable fluctuation. Conclusion: We believe that the newly proposed pcsr QA would be useful and helpful to predict the mid-term quality of real VMAT treatment delivery.

765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책 (The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection)

  • 안상필;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

일정 부하 수축 시 수집한 표면근전도 신호에서 검출한 15개 특성 변수들의 노화에 따른 차이 (Age-related difference of the 15 Characteristics Variables in Surface EMG Signals Generated Under Constant Load Contraction)

  • 이진;유인규;김세동
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1674-1680
    • /
    • 2008
  • The objective of this study is to compare age-related differences of 15 characteristic variables estimated from SEMG signals, which were obtained from the old group(62 subjects) and young group(72 subjects). The SEMG signals were recorded from biceps brachii muscle under sustained isometric elbow flexion contraction with constant load(4kg dumbbell) during 30 seconds. Ten time domain (ARV, RMS, MSA, MTA, ZC, MSF, MTF, MSD, MTD, MSS) and five frequency domain(MNF, MDF, $f_{max}$, $P_{max}$, $P_{to}$) variables were extracted from the SEMG signals and then statistically analyzed, respectively. The findings of the analysis indicate significant age-related differences in the SEMG signal during constant load contraction.

능동 위상 배열 SAR 안테나를 위한 X-대역 송수신 모듈의 설계 및 제작 (A Design and Fabrication of the X-Band Transmit/Receive Module for Active Phased Array SAR Antennas)

  • 정민길;김상근;나형기;이종환;이동우;백승훈
    • 한국전자파학회논문지
    • /
    • 제20권10호
    • /
    • pp.1050-1060
    • /
    • 2009
  • 본 논문에서는 능동 위상 배열 안테나를 가지는 SAR(Synthetic Aperture Radar)용 X-대역 T/R(Transmit/Receive) 모듈을 설계, 제작하였다. T/R 모듈은 X-대역에서 800 MHz 이상 대역폭을 가지며 이중 편파 운용이 가능하다. 송신 출력 7 W 이상에 잡음지수 3.9 dB 이하를 가진다. 위상과 이득은 6비트 위상변위기와 6비트 디지털 감쇠기에 의해 각각 제어된다. 게다가 제작된 T/R 모듈은 방향성 결합기와 전력분배기로 연결되는 성능 점검/보정 포트를 가진다. LTCC 다층 기판을 사용하여 고직접화 T/R 모듈이 가능하게 하였다. 모든 동작 주파수 대역에서 수신시 RMS 이득 오차는 최대 0.8 dB 이하이고, 송/수신시 RMS 위상 오차는 최대 $4^{\circ}$ 이하로 측정되었고, 또한 시험 결과 T/R 모듈은 요구되는 전기적인 성능을 만족하였다. 이 구조는 능동 위상 배열 SAR용 안테나에 적용될 수 있음을 확인하였다.

비선형 해양파의 통계적 특성에 대한 해석 (An Analysis of Statistical Characteristics of Nonlinear Ocean Waves)

  • 김도영
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제13권2호
    • /
    • pp.112-120
    • /
    • 2010
  • 이 논문에서는 Yura 해역에서 폭풍 중 24시간 연속으로 측정된 freak wave가 포함된 파랑자료를 분석하여 비선형 파도의 통계적 특성을 살펴보았다. 파고의 초과확률분포는 Edgeworth-Rayleigh(ER) 분포와, Rayleigh 분포를 이용하여 계측된 자료와 비교하였다. 파형이 stationary 상태를 유지하는 10시간 동안 계측된 파랑자료(파랑의 개수가 4600 내외)에서는, 파형의 분포는 Gram-Chalier분포가 Gaussian분포보다 파랑자료와 일치를 한다. 전반적인 파고의 확률분포는 Rayleigh($H_{rms}$)분포를 잘 따르는 것을 볼 수 있다. Freak wave 발생확률은 Rayleigh($m_{o}{^{1/2}}$) 분포로 잘 표시가 되며, ER 분포는 과대하게 예측하는 것을 볼 수 있다. 30분간 계측된 파랑자료(파랑 개수가 250개 내외)에서 freak wave가 발생된 경우는 ER 분포가 freak wave 발생확률과 잘 일치한다. 그러나 전반적인 파고의 발생확률이 과대평가된다. Freak wave가 발생하지 않은 경우는 거의 모든 파고에 걸쳐 Rayleigh($H_{rms}$)분포가 계측된 파고분포와 잘 일치를 한다. 파고가 10 m 이하의 freak wave의 파고확률분포는 10 m 이상의 파고를 가지는 freak wave와 비슷한 경향을 보인다. $H_{max}/H_{1/3}$은 파형의 kurtosis와 연관이 있는 것을 보여주었다. Freak wave의 발생은 높은 kurtosis 값과 관계가 있으며, freak wave가 발생하는 임계 kurtosis 값이 존재할 가능성이 있을 것으로 추정된다.

연식주퇴 시스템 포신고정 장치의 동적 해석 (A Dynamic Analysis on the Latch of Soft Recoil System)

  • 우대현;이영신;김흥태;전상배;이규섭;강국정
    • 한국군사과학기술학회지
    • /
    • 제15권4호
    • /
    • pp.359-365
    • /
    • 2012
  • In the soft recoil system, the recoiling parts are initially accelerated to the forward direction. These parts are returned to original position by the firing with intial acceleration speed. The latch of the soft recoil system keeps the high impact load when the recoil parts were recuperated to the forward direction. In this study, the latch of soft recoil system using the ADAMS program was analyzed. The optimal operation parameters were found that max. angle and expansion length of latch was $50^{\circ}$, 180 mm respectively. Dynamic structural analyses of model cases were performed using finite element model. The max. stress and deflection of latch was 230 MPa and 0.45 mm respectively.

누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가 (The Evaluation of Ageing Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring)

  • 김정호;서광석;문중섭;양계준;조한구;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2408-2410
    • /
    • 1999
  • The ageing process was checked by leakage current monitoring in Inclined-Plane Method. In order to monitor leakage current, DAS with 12-bit, 8-channel A/D converter was prepared. The monitored components of leakage current were averages of the rms and peak, max peak, cumulative charge, and the number of peaks in the ranges of 1-10, 10-20, 20-30, 30-40, 40-50, >50 mA. And, erosion depth was measured to be used as the index of the ageing. So, the results of leakage current components and erosion depth measurement were compared to find one or more components of which trends of changes were similar to that of erosion.

  • PDF

플라스틱 BGA 패키지의 아르곤 가스 플라즈마 처리 효과 (Effect of Ar Gas Plasma Treatment of Plastic Ball Grid Array Package)

  • 신영의;김경섭
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.805-811
    • /
    • 2000
  • Reliability of PBGA(plastic ball grid array) package is weak compared with normal plastic packages. The low reliability is caused by low resistance to the popcorn cracking, which is generated by moisture absorption in PCB(prited circuit board). In this paper, plasma treatment process was used and we analyzed its effects to interface adhesion. The contents of C and Cl decrease after plasma treatment but those of O, Ca, N relatively increase. The plasma treatment improves the adhesion between EMC(epoxy molding compound) and PCB(solder mask). The grade of improvement was over 100% Max, which depends on the properties of EMC. The RMS(root mean square) roughness value of the solder mask surface increases to plasma treatment. There is little difference of adhesion in RF power and treatment time.

  • PDF