Experimental Study on the Measurement of Fire Behavior and Heat Release Rate in Building Compartment Space - Focus on Full Scale Fire Test of the Bed Mattress - (건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구 - 실물규모 침대 매트리스 화재시험 중심으로 -)

  • Seo, Bo-Youl;Jang, Woo-Bin;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space, a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets (KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), the maximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was 992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in the test room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement time according to the test location was confirmed.

A Case of Rentention Sutures of Vaginal Prolapse in a Dairy Cow (유우의 질탈교정술의 일예)

  • Cho Myoung-Rae
    • Journal of Veterinary Clinics
    • /
    • v.9 no.1
    • /
    • pp.311-316
    • /
    • 1992
  • Four retention sutures were used to correct the vaginal prolapse in a dairy cow. The methods used were two modified Caslick operation of vulva using absorbable(catgut chromic) and nonabsorbable(supramid) materials, and a modified mattress closure and a modified Buhner method of vulva using trocar and wire insulated by vinyl. The lasting periods for retention of bovine vaginal prolapse by the suture methods described above, were 12 days, 49 days, 39 days and 62 days respectively.

  • PDF

개(犬)에 있어서 크게 손상된 피부의 접합에 관한 두가지의 Tenion Suture (감장봉합)에 관한 술식상의 평가

  • Jacobs Robert Mitchell
    • Journal of the korean veterinary medical association
    • /
    • v.18 no.12
    • /
    • pp.29-34
    • /
    • 1982
  • 두가지 방법의 Tension Suture가 개에서 손상을 입은 피부의 접합에 평가되어졌다. 이들 술식은 Vertical Mattress Tension Suture와 'Walking'봉합이다. 7주후에 타원형으로 손상된 피부의 반흔조직을 추적하여 면적을 측정하였다. 흠손된 피부의 반흔조직의 평균 넓이는 V.M.T.S의 $5.29cm^2$에 비해 'Walking'봉합의 경우는 $2.07cm^2$였다. 이는 'Walking'봉합의 경우가 명백히 반흔조직이 좁다는 것이 관찰되었다. 더구나 어떤 손상의 경우더라도 'Walking'봉합은 열개(봉합한 자국)가 발견되지 아니했다.

  • PDF

Analysis on surface flame spread on bed mattress in fire (침대 매트리스 화새시 표면 화염확산성 분석)

  • Park, Kye-Won;Jeong, Jae-Gun;Yang, Woo-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.35-36
    • /
    • 2013
  • 2차 화염확산체로서의 역할을 할 수 있는 일반 유기폼 침대 매트리스에 착화된 연소성상을 고찰하며 특히 표면 화염확산(flame spread)에 대해서 장방향 및 단방향에 대한 확산속도를 분석함.

  • PDF

An experimental study on the fire characteristics of liquid accelerant over furniture(mattress) (가구(침대)의 유류방화 특성에 관한 실험적 연구)

  • Kim, Soo-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.235-240
    • /
    • 2010
  • 본 연구는 침대 매트리스를 초기 가연물로하여 소량의 인화성 액체를 사용한 방화 화재 특성에 관한 실험적 연구로서 인화성액체의 spill형태에 따른 가연물의 연소속도, 연소 Patterns의 분석과 동일한 공간 가연물에서 일반화재와 유류방화의 비교 실대 화재 실험 및 실험 현장에서 수거한 유류증거물의 인화성액체 종류별, 증거물의 상태에 따른 GC/Mass 분석 결과특성에 관한 연구이다.

  • PDF

Design and Evaluation of a Low-floor Care-bed for Elderly People (고령자용 저상 요양침대의 설계 및 평가)

  • Bae, Ju-Hwan;Moon, Inhyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • It was hard for a conventional care-bed to be realized to a low-floor position due to a complex actuation mechanism installed under the mattress support platform. In this paper a mechanism design to set a low-floor position as well as to adjust back- and leg-rest angles was proposed. A dual motor was applied to the back- and leg-rest mechanism of which design parameters were determined by an optimal method. An elevation mechanism was also designed to enlarge a limited stroke range up to two times of its original stroke using a pulley mechanism. An evaluation test was performed by five healthy subjects ($24.4{\pm}0.5yrs.$) when going up from a floor position to a preset best position which was set to the 240mm height for a prototype low-floor bed and to the 600mm height for a conventional bed. As a result, the moving distance was 38% lower than the conventional bed when the subject used the low-floor bed. It showed that the low-floor care-bed reduced physical burdens and was effective to assist activities of daily living of the elderly people.

Dynamic Characterization of Fall for Development of Fracture Prevention System (골절 방지 시스템의 개발을 위한 낙상 동적 특성 분석)

  • Kim, Seong-Hyun;Kim, Yong-Yook;Kwon, Tae-Kyu;Kim, Dong-Wook;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.811-816
    • /
    • 2007
  • The social activities of the elderly have been increasing as our society progresses toward an aging society. As their activities are increased, the occurrence of falls that could lead to fractures are increased. Falls are serious health hazards to the elderly and we need more thorough understanding of falls including the progress of falls and the impact area in various fall directions. Many of the traditional methods of falls research dealt with voluntary falls by younger subject since older subject can easily get fracture from voluntary falls. So, it has been difficult to get exact data about falls of the elderly. Here, we tried to capture the characteristics of the movements of major joints using three dimensional motion capture system during falls experiments using a moving mattress that can safely induce unexpected falls. Healthy younger subjects participated in the actual falls experiment and the moving mattress was actuated by a pneumatic system. The kinematic parameters such as velocities and accelerations of major segments were imported to a computer simulation environment and falls to hard surfaces were simulated in a computational environment using a realistic human model of aged persons. The simulation was able to give approximations to contact forces which can occur during actual falls.

A Study on the Flow Coefficient of Compartment Fire (건물화재시 개구부의 흐름계수에 관한 연구)

  • 허만성
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.19-27
    • /
    • 1996
  • The objective of this research is to study on the upper layer temperature, interface height and flow regime in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The upper layer temperature and the Interface height were relatively well agreed with the experimental results when the flow coefficient at the opening was 0.65-0.8 for the rectangular trashcan, 0.65-0.9 for the circular trashcan and chair, and 0.7-0.9 for the carpet, sofa, mattress and wardrobe. The interface heights for the seven furniture fires were around 1[m] maintaining steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25[m]-0.75[m] from the floor. The flow regime at the opening was filling and buoyant for the distributed fire, and for the concentrated fire it was filling and then quickly changed to flow, and the flow period was long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the contact surface area with air. The time required to come down around 1[m] was within 1-3 minutes.

  • PDF

Fall Simulation and Impact Absorption system for Development of Fracture Prevention System (골절 방지 시스템의 개발을 위한 낙상 시뮬레이션과 충격 흡수 시스템에 관한 연구)

  • Kim, S.H.;Kim, D.W.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.438-448
    • /
    • 2010
  • The social activities of the elderly have been increasing as our society progresses toward an aging society. As their activities are increased, the occurrence of falls that could lead to fractures are increased. Falls are serious health hazards to the elderly and we need more thorough understanding of falls including the progress of falls and the impact area in various fall directions. Many of the traditional methods of falls research dealt with voluntary falls by younger subject since older subject can easily get fracture from voluntary falls. So, it has been difficult to get exact data about falls of the elderly. Here, we tried to capture the characteristics of the movements of major joints using three dimensional motion capture system during falls experiments using a moving mattress that can safely induce unexpected falls. Healthy younger subjects participated in the actual falls experiment and the moving mattress was actuated by a pneumatic system. The kinematic parameters such as velocities of major segments were imported to a computer simulation environment and falls to hard surfaces were simulated in a computational environment using a realistic human model of aged persons. The simulation was able to give approximations to contact forces which can occur during actual falls. And we designed impact absorption system to reduce the impact during falls. We can adapt this system to fracture prevention system that we are going to study.

Continuous "Over and Over" Suture for Tricuspid Ring Annuloplasty

  • Park, Kwon-Jae;Woo, Jong-Soo;Jeong, Sang-Seok;Yi, Jung-Hoon
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.19-23
    • /
    • 2012
  • Background: A ring implantation in the tricuspid annulus requires many interrupted mattress sutures for correction of tricuspid regurgitation (TR). In this study, tricuspid ring annuloplasty was performed by 2-0 polypropylene continuous suture instead of multiple interrupted 2-0 polyester mattress sutures, and the efficacy of the method was evaluated. Materials and Methods: This study included 20 patients who underwent tricuspid ring annuloplasty by continuous suture between May 2009 and July 2010. Four of the patients had an isolated TR, and the rest had a left-sided cardiac lesion. The concomitant tricuspid annuloplasty was performed after the left-sided heart surgery was completed and a Duran flexible ring prosthesis was used. Results: There was no perioperative mortality or conduction problem. More than a moderate degree of TR was improved to less than a mild degree after the procedure. After the ring annuloplasty, the right atrial volume decreased from $123.7{\pm}69.2mL$ to $74.5{\pm}37.4mL$, and the mean right atrial pressure was lowered from $18.7{\pm}12.2mmHg$ to $8.9{\pm}5.5mmHg$. Conclusion: The continuous "over and over" suture may be a useful procedure for fixing the ring to the annulus and making an intentional annular placation in performing tricuspid ring annuloplasty.