• Title/Summary/Keyword: Material parameters

Search Result 4,533, Processing Time 0.036 seconds

Quality and Shelf-Life of Vacuum Packed RTE (Ready-To-Eat) Hamburg Steak Depending on the Oxygen Permeability of Packaging Material and the Storage Temperature (포장재의 산소투과도와 저장온도에 따른 즉석섭취형 햄버그스테이크의 품질 및 저장성)

  • Lim, Ji Hoon;Lee, Sung Ki;Chung, Seung Hee;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • This study investigated the effects of the oxygen permeability of vacuum packaging film and the storage temperature on the quality and shelf life of Hamburg steaks during storage for 14 days. Control samples (C) were packaged in a polyamide/polyethylene (PA/PE) film and stored at $5^{\circ}C$. Treatment samples were either packaged in an ethylene vinyl alcohol/polyethylene (EVOH/PE) copolymer film and stored at $5^{\circ}C$ (T1), and in a PA/PE film and stored at $-18^{\circ}C$ (T2). The initial total plate count (TPC) was 3.6 log cfu/g. In T1 samples, TPC and Brochothrix thermosphacta counts were increased, similar to those in C samples, whereas Pseudomonas spp. counts were significantly lower than those in C samples during storage. Over the storage period, the volatile basic nitrogen values increased most rapidly in C samples, followed by T1 and then T2 samples. The values of thiobarbituric acid reactive substances steadily increased in all samples during storage. The colour parameters were not significantly different among the samples during storage. T1 samples maintained sensory qualities in flavour and off-odour parameters for two days longer than C samples did. At day 12, T2 samples were evaluated as being below the marketability score of 5.0 for texture. In conclusion, using high oxygen barrier films like EVOH/PE copolymer for packaging Hamburg steaks could extend the sensory qualities in view of flavour and off-odour during chilled storage. However, frozen storage at $-18^{\circ}C$ is recommended when the storage period is extended beyond 14 days at $5^{\circ}C$.

Composting of Livestock Waste and Development of Operating Parameters I. Development of Optimum Process Parameters in Cow Manure Composting (축산 폐기물의 퇴비화 및 운용지표 개발 I. 우분의 퇴비화에 있어서 최적 공정운용지표의 개발)

  • Chung, Jae-Chun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.1 no.1
    • /
    • pp.69-84
    • /
    • 1993
  • In order to determine the optimum operational paramsters in cow manure composting, 4 laboratory scale composters were established. The cow manure was mixed with certain amount of saw dust to adjust the initial C/N ratio to 24, initial pH to 6.9 and composting was performed with varying operational conditions. It was found that the optimum aeration rate was 1000 ml/min kg. VS, the optimum moisture content 50% and no significant difference was found with different initial pH condition. Microorganisms were counted under the optimum conditions determined in this study. At the end of the experimental period, the number of bacteria, actinomycetes and fungi was $1.5{\times}10^9$ cells, $1.1{\times}10^8$ cells and $3.0{\times}10^8$ cells/g dry compost, respectively. At day 0, the number of coliforms, fecal coliforms and fecal streptococci was $3.1{\times}10^3$ cells, $7.5{\times}10^2$ cells and $5.6{\times}103$ cells/g dry composting material, respectively. Their population was decreased with time lapse, However, their survival time was longer than those reported by other researchers. Microorganisms were identified at the end of the experiment. Genus Bacillus was the most dominant comprising 89.3% of the total population. Among the Genus Bacillus, B. circulans compoex was the most abundant, followed by B. Stearothermophilus, B. Sphericus, B. licheniformis and B, brevis.

  • PDF

The Changes of Cerebral Metabolic Parameters, Serum Levels of Neuron-Specific Enolase and S-100$\beta$ Protein During Retrograde Cerebral Perfusion Under Profound Hypothermic Total Circulatory Arrest (초저체온하 완전순환정지 시에 이용되는 역행성 뇌관류의 시간에 따른 뇌대사 지표, 혈청 내 neuron-specific enolase, 및 S-100 베타단백의 변화)

  • 김경환
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.653-661
    • /
    • 2001
  • Background: Retrograde cerebral perfusion(RCP) is one of the methods used for brain protection during aortic arch surgery. The author previously published the data, however, for the safety of it, there still remains many controversies. The author performed RCP and checked various parameters to clarify the possibility of early detection of cerebral injury. Material and Method: The author used pigs(Landrace species) weighing 25 to 30kg and performed RCP for 120 minutes. After weaning of cardiopulmonary bypass, we observed pigs for another 120 minutes. Rectal temperature, jugular venous oxygen saturation, central venous pressure were continuously monitored, and the hemodynamic values, histological changes, and serum levels of neuron-specific enolose(NSE) and S100$\beta$ protein were checked. Central venous pressure during RCP was maintained in the range of 20 to 25 mmHg. Result: Flow rates(ml/min) during RCP were 224.3$\pm$87.5(20min), 227.1$\pm$111.0(40min), 221.4$\pm$119.5(60min), 230.0$\pm$136.5(80min), 234.3$\pm$146.1(100min), and 184.3$\pm$50.5(120min). Serum levels of NSE did not increase after retrograde cerebral perfusion. Serum levels of S100$\beta$ protein(ng/ml) were 0.12$\pm$0.07(induction of anesthesia), 0.12$\pm$0.07(soon after CPB), 0.19$\pm$0.12(20min after CPB), 0.25$\pm$0.06(RCP 20min), 0.29$\pm$0.08(RCP 40min), 0.41$\pm$0.05(60min), 0.49$\pm$0.03(RCP 80min), 0.51$\pm$0.10(RCP 100min), 0.46$\pm$0.11(RCP 120min), 0.52$\pm$0.15(CPBoff 60min), 0.62$\pm$0.15(60min after rewarming), 0.76$\pm$0.17(CPBoff 30min), 0.81$\pm$0.20(CPBoff 60min), 0.84$\pm$0.23(CPBoff 90min) and 0.94$\pm$0.33(CPBoff 120min). The levels of S100$\beta$ after RCP were significantly higher than thosebefore RCP(p<0.05). The author could observe the mitochondrial swellings using transmission electron microscopy in neocortex, basal ganglia and hippocampus(CA1 region). Conclusion: The author observed the increase of serum S100$\beta$ after 120 minutes of RCP. The correlation between its level and brain injury is still unclear. The results should be reevaluated with longterm survival model also considering the confounding factors like cardiopulmonary bypass.

  • PDF

The Relationship of the LV Systolic Function, the LV Dimension and the LV Mass to QT Dispersion in Stable Angina Patients who are with or without Significant Coronary Stenosis (안정성협심증 환자에서 저명한 관상동맥 협착 유무와 좌심실 수축기능, 용적, 질량과 QT Dispersion 간의 관계)

  • Kwon, Jong-Bum;Yoon, Hee-Jeoung;Jin, Seung-Won;Her, Sung-Ho;Kim, Hyung-Doo;Kim, Kyung-Soo;Lee, Jong-Ho;Park, Khun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.439-446
    • /
    • 2008
  • Background: The aim of this study was to investigate the relationship of the left ventricular (LV) systolic function, the LV dimension and the LV mass with the QT dispersion in patients with stable angina, and we also wanted to compare this relationship between patients with and without significant coronary stenosis on coronary angiography. Material and Method: 174 patients complained of typical angina and they had no associated ST segment or cardiac enzyme abnormalities. The patients were divided into 2 groups based on the results of coronary angiography: the patients with angiographic coronary stenosis ${\geq}50%$ made up group I (n=101), and the patients with angiographic coronary stenosis <50% made up group II (n=73). An echocardiogram for assessing the LV ejection fraction (EF), the LV dimension and the LV mass and a 12.lead electrocardiogram for assessing the QT dispersion were performed before the coronary angiography. Result: The QT dispersion was significantly greater in group I than that in group II (39.8 ms vs. 33.3 ms; p<0.05). For all the patients, all the parameters of LV dimension and LV mass had statistically positive correlation to the QT dispersion, but the LV mass was the only independently significant parameter that was correlated with the increased QT dispersion (p<0.05). For group I, none of the echocardiographic parameters had significant correlation with the QT dispersion. However, the LV dimension and LV mass had significantly positive correlation with the QT dispersion, and the LV mass was also the only independently significant parameter that was correlated with increased QT dispersion in group II (p<0.05). Conclusion: Our study demonstrated a significantly positive correlation of the QT dispersion to the LV dimension and the LV mass in patients with stable angina. These findings are present only in patients without significant coronary stenosis.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Expression of Hypoxia-inducible Factor-1 $\alpha$ in Esophageal Squamous Cell Carcinoma: Relationship to Prognosis and Tumor Biomarkers (식도 편평세포암에시 Hypoxia-inducible Factor-1 $\alpha$의 발현: 예후와 종양표지자와의 상관성)

  • 양일종;김종인;이해영;천봉권;조성래
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.691-701
    • /
    • 2004
  • Background: Tissue hypoxia is a characteristic of many human malignant neoplasms, and hypoxia inducible factor-1 (HIF-1) plays a pivotal role in essential adaptive response to hypoxia, and activates a signal pathway for the expression of the hypoxia-regulated genes, resulting in increased oxygen delivery or facilitating metabolic adaptation to hypoxia. Increased level of HIF-1 a has been reported in many human malignancies, but in esophageal squamous cell carcinoma, the influence of HIF-1 a on tumor biology, including neovascularization, is not still defined. Material and Method: The influence of HIF-1 a expression on angiogenic factors, correlation between the tumor proliferation and HIF-1 a expression, interaction of HIF-1 a expression and p53, and correlation between HIF-1 a expression and clinicopathological prognostic parameters were investigated, using immunohistochemical stains for HIF-1 a, VEGF, CD34, p53, and Ki-67 on 77 cases of resected esophageal squamous cell carcinoma. Result: HIF-1 a expression in cancer cells was found in 33 of 77 esophageal squamous cell carcinoma cases. The 33 cases (42.9%) showed positive stain for HIF-1 a. High HIF-1 a expression was significantly associated with several pathological parameters, such as histologic grade (p=0.032), pathological TMN stage (p=0.002), the depth of tumor invasion (p=0.022), regional lymph node metastasis (p=0.002), distant metastasis (p=0.049), and lymphatic invasion (p=0.004). High HIF-1 a expression had significant VEGF immunoreactivity (p=0.008) and Ki-67 labeling index (p<0.001), but was not correlated with microvascular density within tumors (p=0.088). The high HIF-1 a expression was correlated with aberrant p53 accumulation with a marginal significance (p=0.056). The overall 5-year survival rate was 34.9%. The survival rate of patients with a high HIF-1 a expression was worse than that of patients with low-expression tumors (log-rank test, p=0.0001). High HIF-1 a expression was independent unfavorable factors although statistical significance is marginal in multivariate analysis. Conclusion: It is suggested that (1) high HIF-1 a expression in esophageal squamous cell carcinoma is associated with tumor hypoxia, or with genetic alteration in early carcinogenesis and progressive stages, (2) high HIF-1 a expression may be associated with intratumoral neovascularization through HIF-VEGF pathway, and (3) high HIF-1 a expression is associated with poor prognosis in patients with esophageal squamous cell carcinoma and may playa role as biomarker for regional lymph node metastasis.

The clinical effects of Calcium Sulfate combined with Calcium Carbonate in treating intrabony defects (치조골 결손부 치료시 calcium carbonate와 calcium sulfate 혼합물의 임상적 효과)

  • Lee, Seung-Bum;Chae, Gyung-Jun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kyu
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: If bone grafts and guided tissue regeneration are effective individually in treating osseous defects, then the questionis, what would happen when they are combined. Bone grafts using Calcium Carbonate(Biocoral) and Guided Tissue Regeneration using Calcium Sulfate(CALMATRIX) will maximize their advantages and show the best clinical results in intrabony defects. This study was to compare the effects of a combination of CS and CC with control treated only with modified widman flap in a periodontal repair of intrabony defects. Materials and Methods: 30 patients with chronic periodontitis were used in this study. 10 patients were treated with a combination of CS and CC as the experimental group II and another 10 patients were treated with CC as the experimental group I, and the remaining 10 patients, the control group were treated only with modified widman flap. Clinical parameters including probing depth, gingival recession, bone probing depth and loss of attachment were recorded 6 months later. Results: The probing depth changes were $3.30{\pm}1.34\;mm$ in the control group, $4.2{\pm}1.55\;mm$ in the experimental group I(CC) and $5.00{\pm}1.33\;mm$ in the experimental group II(CS+CC). They all showed a significant decrease 6 months after surgery(p<0.01). There was a significant difference(p<0.05) between the control and experimental group. However there were no significant difference(p<0.05) between the experimental group I and II. The gingival recession changes w $-1.30{\pm}1.25\;mm$ in the control group, This is a significant difference(p<0.01). However, there was a $-0.50{\pm}0.53\;mm$ change in the experimental group I(CC) and $-0.60{\pm}0.97\;mm$ in the experimental group II(CS+CC). In addition, in terms of gingival recession, there was a no significance difference(p<0.05) among the groups. The clinical attachment level changes were $2.00{\pm}1.33\;mm$ in the control group, $3.60{\pm}1.58\;mm$ in the experimental group I(CC) and $4.40{\pm}1.17\;mm$ in the experimental group II(CS+CC). They all showed a significant decrease 6 months after surgery(p<0.01). There was a significant difference(p<0.05) between the control and experimental group. However there was a no significance difference(p<0.05) between the experimental group I and II. The bone probing depth changes were $0.60{\pm}0.52\;mm$ in the control group, $3.20{\pm}1.48\;mm$ in the experimental group I(CC) and $4.60{\pm}1.43\;mm$ in the experimental group II(CS+CC). All of them showed a significant decrease 6 months after surgery(p<0.01), there was a significance difference(p<0.05) among the groups. Conclusion: Treatment using a combination of CS and CC have a potential to improve periodontal parameters in intrabony defects and More efficient clinical results can be expected in intrabony defects less than 2 walls grafted with CS and CC.

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Measurement of the Quantity of Hydrogen Peroxide Produced in the Ultrasound-irradiated Aqueous Solution of Organic Compounds (초음파를 조사(照射)한 유기화합물 수용액 속에서의 과산화수소 생성량의 측정)

  • Mo, Se-Young;Chang, Hong-Ki;Lee, Kyung-Jae;Jang, Gun-Eik;Sohn, Jong-Ryeul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.61-71
    • /
    • 2000
  • When irradiate the power ultrasound into the aqueous solutions, water vapor is decomposed by the heat of very high temperature in the cavitation bubble to produce OH (hydroxyl radical) and H (hydrogen radical), and these radicals play a role in decomposing the substances in aqueous solution by oxidation and/or reduction, and in producing the hydrogen peroxide. Accordingly it is possible to predict that the quantity of hydrogen peroxide produced may correlate with the sonolysis mechanism of the substance in aqueous solution. Thus to confirm this prediction, the quantities of hydrogen peroxide produced from each of the air saturated distilled water and three aqueous solutions of TCE, benzene, and 2,4-DCP that are prepared by dissolving them into distilled water are measured. As a result, it showed that the quantity of hydrogen peroxide produced from the distilled water and three aqueous solutions are increased in order of distilled water>TCE solution>2,4-DCP solution>benzene solution, and decrease with decrease in concentration of organic substance, which coincide with the sonolysis mechanisms reported that TCE in aqueous solution is decomposed directly by the pyrolysis in and around the cavitation bubbles when its concentration is high and by the radical reaction when low, however, benzene and 2,4-DCP are decomposed not only by the pyrolysis but also by the radical reactions. Effects of such experimental parameters as the acoustic frequency and power and as the concentration showed that the higher the acoustic frequency and the lower the acoustic power, the less the quantity of hydrogen peroxide was produced. This result coincide with the theory of ultrasound for the relation between the cavitation that is the energy source of the power ultrasound in aqueous solution and these experimental parameters.

  • PDF

A Numerical and Experimental Study for Fry-drying of Various Sludge (슬러지 유중 건조에 대한 전산 해석 및 실험적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Kim, Byeong-Gap;Hwang, Min-Jeong;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • The basic principle of fry drying process of sludge lies in the rapid pressure change of sludge material caused by the change of temperature between oil and moisture due to the difference of specific heat. Therefore, the rapid increase of pressure in drying sludge induces the efficient moisture escape through sludge pores toward heating oil media. The object of this study is to carry out a systematic investigation of the influence of various parameters associated with the sludge fry drying processes on the drying efficiency. To this end, a series of parametric experimental investigation has been made together with the numerical calculation in order to obtain typical drying curves as function of important parameters such as drying temperature, sludge diameter, oil type and sludge type. In the aspect of frying temperature, especially it is found that the operation higher than $140^{\circ}C$ was favorable in drying efficiency regardless of type of waste oil employed in this study. The same result was also noted consistently in the investigation of numerical calculation, that is, in that the sludge particle drying was efficiently made over $140^{\circ}C$ irrespective of the change of particle diameter. As expected, in general, the decrease of diameter in sludge was found efficient both experiment and numerical calculation in drying due to the increased surface area per unit volume. In the investigation of oil type and property, the effect of the viscosity of waste oil was found to be more influential in drying performance. In particular, when the oil with high viscosity, a visible time delay was noticed in moisture evaporation especially in the early stage of drying. However, the effect of high viscosity decreased significantly over the temperature of $140^{\circ}C$. There was no visible difference observed in the study of sludge type but the sewage sludge with a slightly better efficiency. The numerical study is considered to be a quite useful tool to assist in experiment with more detailed empirical modeling as further work.