• 제목/요약/키워드: Material damping

검색결과 575건 처리시간 0.03초

Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge

  • Zahrai, Seyed Mehdi;Froozanfar, Mohammad
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.449-466
    • /
    • 2019
  • Cable-stayed bridges are attractive due to their beauty, reducing material consumption, less harm to the environment and so on, in comparison with other kinds of bridges. As a massive structure with long period and low damping (0.3 to 2%) under many dynamic loads, these bridges are susceptible to fatigue, serviceability disorder, damage or even collapse. Tuned Mass Damper (TMD) is a suitable controlling system to reduce the vibrations and prevent the threats in such bridges. In this paper, Multi Tuned Mass Damper (MTMD) system is added to the Ahvaz cable stayed Bridge in Iran, to reduce its seismic vibrations. First, the bridge is modeled in SAP2000 followed with result verification. Dead and live loads and the moving loads have been assigned to the bridge. Then the finite element model is developed in OpenSees, with the goal of running a nonlinear time-history analysis. Three far-field and three near-field earthquake records are imposed to the model after scaling to the PGA of 0.25 g, 0.4 g, 0.55 g and 0.7 g. Two MTMD systems, passive and active, with the number of TMDs from 1 to 8, are placed in specific points of the main span of bridge, adding a total mass ratio of 1 to 10% to the bridge. The parameters of the TMDs are optimized using Genetic Algorithm (GA). Also, the optimum force for active control is achieved by Fuzzy Logic Control (FLC). The results showed that the maximum displacement of the center of the bridge main span reduced 33% and 48% respectively by adding passive and active MTMD systems. The RMS of displacement reduced 37% and 47%, the velocity 36% and 42% and also the base shear in pylons, 27% and 47%, respectively by adding passive and active systems, in the best cases.

Multi-mode cable vibration control using MR damper based on nonlinear modeling

  • Huang, H.W.;Liu, T.T.;Sun, L.M.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.565-577
    • /
    • 2019
  • One of the most effective countermeasures for mitigating cable vibration is to install mechanical dampers near the anchorage of the cable. Most of the dampers used in the field are so-called passive dampers where their parameters cannot be changed once designed. The parameters of passive dampers are usually determined based on the optimal damper force obtained from the universal design curve for linear dampers, which will provide a maximum additional damping for the cable. As the optimal damper force is chosen based on a predetermined principal vibration mode, passive dampers will be most effective if cable undergoes single-mode vibration where the vibration mode is the same as the principal mode used in the design. However, in the actual engineering practice, multi-mode vibrations are often observed for cables. Therefore, it is desirable to have dampers that can suppress different modes of cable vibrations simultaneously. In this paper, MR dampers are proposed for controlling multi-mode cable vibrations, because of its ability to change parameters and its adaptability of active control without inquiring large power resources. Although the highly nonlinear feature of the MR material leads to a relatively complex representation of its mathematical model, effective control strategies can still be derived for suppressing multi-mode cable vibrations based on nonlinear modelling, as proposed in this paper. Firstly, the nonlinear Bouc-wen model is employed to accurately portray the salient characteristics of the MR damper. Then, the desired optimal damper force is determined from the universal design curve of friction dampers. Finally, the input voltage (current) of MR damper corresponding to the desired optimal damper force is calculated from the nonlinear Bouc-wen model of the damper using a piecewise linear interpolation scheme. Numerical simulations are carried out to validate the effectiveness of the proposed control algorithm for mitigating multi-mode cable vibrations induced by different external excitations.

Study of cracks in compressed concrete specimens with a notch and two neighboring holes

  • Vahab, Sarfarazi;Kaveh, Asgari;Shirin, Jahanmiri;Mohammad Fatehi, Marji;Alireza Mohammadi, Khachakini
    • Advances in concrete construction
    • /
    • 제14권5호
    • /
    • pp.317-330
    • /
    • 2022
  • This paper investigated computationally and experimentally the interaction here between a notch as well as a micropore under uniaxial compression. Brazilian tensile strength, uniaxial tensile strength, as well as biaxial tensile strength are used to calibrate PFC2d at first. Then, uniaxial compression test was conducted which they included internal notch and micro pore. Experimental and numerical building of 9 models including notch and micro pore were conducted. Model dimensions of models are 10 cm × 10 cm × 5 cm. Joint length was 2 cm. Joints angles were 30°, 45° and 60°. The position of micro pore for all joint angles was 2cm upper than top of the joint, 2 cm upper than middle of joint and 2 cm upper than the joint lower tip, discreetly. The numerical model's dimensions were 5.4 cm × 10.8 cm. The fractures were 2 cm in length and had angularities of 30, 45, and 60 degrees. The pore had a diameter of 1 cm and was located at the top of the notch, 2 cm above the top, 2 cm above the middle, and 2 cm above the bottom tip of the joint. The uniaxial compression strength of the model material was 10 MPa. The local damping ratio was 0.7. At 0.016 mm per second, it loaded. The results show that failure pattern affects uniaxial compressive strength whereas notch orientation and pore condition impact failure pattern. From the notch tips, a two-wing fracture spreads almost parallel to the usual load until it unites with the sample edge. Additionally, two wing fractures start at the hole. Both of these cracks join the sample edge and one of them joins the notch. The number of wing cracks increased as the joint angle rose. There aren't many AE effects in the early phases of loading, but they quickly build up until the applied stress reaches its maximum. Each stress decrease was also followed by several AE effects. By raising the joint angularities from 30° to 60°, uniaxial strength was reduced. The failure strengths in both the numerical simulation and the actual test are quite similar.

Impact of viscoelastic foundation on bending behavior of FG plate subjected to hygro-thermo-mechanical loads

  • Ismail M. Mudhaffar;Abdelbaki Chikh;Abdelouahed Tounsi;Mohammed A. Al-Osta;Mesfer M. Al-Zahrani;Salah U. Al-Dulaijan
    • Structural Engineering and Mechanics
    • /
    • 제86권2호
    • /
    • pp.167-180
    • /
    • 2023
  • This work applies a four-known quasi-3D shear deformation theory to investigate the bending behavior of a functionally graded plate resting on a viscoelastic foundation and subjected to hygro-thermo-mechanical loading. The theory utilizes a hyperbolic shape function to predict the transverse shear stress, and the transverse stretching effect of the plate is considered. The principle of virtual displacement is applied to obtain the governing differential equations, and the Navier method, which comprises an exponential term, is used to obtain the solution. Novel to the current study, the impact of the viscoelastic foundation model, which includes a time-dependent viscosity parameter in addition to Winkler's and Pasternak parameters, is carefully investigated. Numerical examples are presented to validate the theory. A parametric study is conducted to study the effect of the damping coefficient, the linear and nonlinear loadings, the power-law index, and the plate width-tothickness ratio on the plate bending response. The results show that the presence of the viscoelastic foundation causes an 18% decrease in the plate deflection and about a 10% increase in transverse shear stresses under both linear and nonlinear loading conditions. Additionally, nonlinear loading causes a one-and-a-half times increase in horizontal stresses and a nearly two-times increase in normal transverse stresses compared to linear loading. Based on the article's findings, it can be concluded that the viscosity effect plays a significant role in the bending response of plates in hygrothermal environments. Hence it shall be considered in the design.

Study on the influence of structural and ground motion uncertainties on the failure mechanism of transmission towers

  • Zhaoyang Fu;Li Tian;Xianchao Luo;Haiyang Pan;Juncai Liu;Chuncheng Liu
    • Earthquakes and Structures
    • /
    • 제26권4호
    • /
    • pp.311-326
    • /
    • 2024
  • Transmission tower structures are particularly susceptible to damage and even collapse under strong seismic ground motions. Conventional seismic analyses of transmission towers are usually performed by considering only ground motion uncertainty while ignoring structural uncertainty; consequently, the performance evaluation and failure prediction may be inaccurate. In this context, the present study numerically investigates the seismic responses and failure mechanism of transmission towers by considering multiple sources of uncertainty. To this end, an existing transmission tower is chosen, and the corresponding three-dimensional finite element model is created in ABAQUS software. Sensitivity analysis is carried out to identify the relative importance of the uncertain parameters in the seismic responses of transmission towers. The numerical results indicate that the impacts of the structural damping ratio, elastic modulus and yield strength on the seismic responses of the transmission tower are relatively large. Subsequently, a set of 20 uncertainty models are established based on random samples of various parameter combinations generated by the Latin hypercube sampling (LHS) method. An uncertainty analysis is performed for these uncertainty models to clarify the impacts of uncertain structural factors on the seismic responses and failure mechanism (ultimate bearing capacity and failure path). The numerical results show that structural uncertainty has a significant influence on the seismic responses and failure mechanism of transmission towers; different possible failure paths exist for the uncertainty models, whereas only one exists for the deterministic model, and the ultimate bearing capacity of transmission towers is more sensitive to the variation in material parameters than that in geometrical parameters. This research is expected to provide an in-depth understanding of the influence of structural uncertainty on the seismic demand assessment of transmission towers.

매립석탄회를 혼합한 유동성 충진재의 동적거동특성 (Dynamic Characteristics of Liquidity Filling Materials Mixed with Reclaimed Ash)

  • 채덕호;김경오;신현영;조완제
    • 한국지반환경공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2014
  • 최근 도심지의 구조물 건설 시 다양한 라이프라인이 공간의 효율적인 활용 측면에서 지중에 매설되고 있으며, 이러한 라이프라인의 신설 및 유지보수 등을 위해 굴착이나 뒤채움 작업이 빈번하게 이루어지고 있다. 라이프라인 매설 시 지반을 굴착하며, 매설 후 채움재 모래를 사용하여 되메움을 하는 것이 일반적이다. 이러한 경우 통신관, 가스관, 상하수도 등의 관하부와 측면 좁은 공간의 뒤채움은 다짐작업이 어려우며, 다짐작업 시 토사의 특성상 추가적으로 침하가 발생한다. 이러한 문제점을 해결하기 위한 방법으로 미국 및 일본 등과 같은 선진국에서 건설 발생토를 재활용하여 잔토처리 비용을 줄이고, 충분한 유동성을 확보한 유동성 채움재가 사용되고 있다. 또한 지중 매설관 건설 외에도 기초 하부 지반의 보강에도 유동성 채움재를 활용할 수 있을 것으로 판단되며, 특히 기계 기초 하부 지지층이 연약한 경우, 유동성 채움재를 적용하여 빠른 시간 안에 지반을 개량하는 목적에 적합할 것으로 판단된다. 특히 기계 기초 하부 지지층의 경우, 단순한 기계 하중에 의한 정적 지지력 산정뿐만 아니라 기계의 진동에 의한 동적 하중이 가해지므로 기초 하부 지지층의 동적거동특성이 평가되어야 한다. 따라서 본 연구에서는 유동성 채움재를 기계 기초 지지층으로 활용하는데 있어서의 적용성을 판별하기 위해 국내에서 일반적으로 볼 수 있는 점토와 황토를 현장발생토로 가정하여 세립분 함량을 달리한 유동성 채움재의 강도 및 동적 거동특성을 파악하였다. 또한 현장 발생토를 대신하여 산업 폐기물인 매립석탄회를 활용하여 유동성 채움재를 조성하여 그 성능을 비교하였다. 그 결과, 매립석탄회를 혼합하여 사용한 경우, 일반적인 건설발생토를 사용한 경우보다 높은 7일 재령 강도와 전단탄성계수를 보였다.

롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발 (Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition)

  • 김성헌;변정섭;지영빈
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.441-447
    • /
    • 2023
  • 현재 의료방사선 분야에서 차폐를 목적으로 주로 사용되고 있는 납(Pb)소재는 방사선 차폐 기능은 뛰어 나지만 납 자체가 가지고 있는 인체 유해성과 무거운 무게에 의한 불편함 때문에 지속적으로 직, 간접적으로 방사선 피폭 위험을 차단함과 동시에 납 소재를 대체할 수 있는 인체 친화적인이며 가벼우면서 사용편의성을 가진 차폐소재의 연구는 지속적으로 진행되어지고 있다. 본 연구에서는 일반적으로 사용되는 PET(polyethylene terephthalate) 필름과 실제 방사선 방호복 사용되는 원단소재를 기재로 하여 방사선을 차폐할 수 있는 금속물질인 비스무트, 텅스텐, 주석을 스퍼터링 진공증착 방식을 통한 다층박막을 구현하여 차페필름을 제작하여 방사선 차폐소재로의 적용가능성을 평가하였다. 차폐필름을 제작하기 위한 인가전압, 롤 구동속력, 가스공급량을 제어하면서 차폐물질별 최적화된 조건을 확립하여 방사선 차폐필름 제작하였다. 모재와 차폐금속박막간 밀착력 확인은 Cross-cut 100/100으로 확인하였고 시간에 따른 박막의 변화를 측정하기 위해 내열탕 테스트 1시간을 통하여 박막의 안정성을 확인하였다. 최종적으로 구현된 차폐필름의 차폐성능은 한국방사선진흥협회를 통한 실제 방사선 차폐성능을 측정한 결과 시험조건(역넓은 빔, 관전압 50 kV, 반가층 1.828 mmAl)을 설정하여 감쇠비 16.4 (초기값 0.300 mGy/s, 측정값 0.018 mGy/s)와 감쇠비 4.31(초기값 0.300 mGy/s, 측정값 0.069 mGy/s)의 결과를 얻었다. 추후 제품화를 위한 공정효율성을 확보하여 가벼우면서 차폐성능을 보유한 필름 및 원단을 활용하여 방사선 방호복이나 차폐기능을 가진 건축자재로의 필름적용을 위한 초석을 마련하였다.

산업폐기물(産業廢棄物)로 발생(發生)되는 석탄회(石炭灰)의 토질력학적(土質力學的) 특성(特性)에 관한 연구(硏究) (Studies on Engneering Properties of Coal Ash Obtained as Industrial Wastes)

  • 천병식;고용일;오민열;권형석
    • 대한토목학회논문집
    • /
    • 제10권1호
    • /
    • pp.115-123
    • /
    • 1990
  • 본(本) 연구(硏究)는 국내(國內) 8개 화력발전소중(火力發電所中) 영동(領東), 영월(寧越), 서천(舒川) 무연탄(無煙炭) 및 삼천포(三千浦), 호남유연탄(湖南有煉炭) 등 5개 화력발전소(火力發電所)에서 부산(富産) 되는 석탄회(石炭灰)에 대하여 건설재(建設材)로서의 활용성(活用性)에 대해 검토(檢討)하고자 화학분석(化學分析), 토질역학시험(土質力學試驗), 지반진동시험(地盤振動試驗) 등을 실시(實施)한 것이다. 석탄회(石炭灰)는 실리카와 알루미나가 약 70%를 차지하고 입도(粒度)는 비회(飛灰)가 fine sand-silt범위(範圍)에 대부분(大部分) 속하고 균등(均等)한 편 이며 저회(底灰)는 sand-gravel 범위(範圍)에 속한다. 비중(比重) 및 단위체적중량(單位體積重量)이 작고 포졸란반응에 의한 자경성(自硬性)이 있어서 장기강도(長期强度)가 증대되며 일반흙에 비해 전단강도가 크다. 무연탄회(無煙炭灰)는 유연탄회(有煙炭灰)에 비해 점착력(粘着力) 및 최적함수비(最適含水比)는 높으나 최대건조밀도(最大乾燥密度)는 낮다. 석탄회(石炭灰)의 동탄성계수곡선분포범위(動彈性係數曲線分布範圍)는 화강토(花岡土)의 것과 비슷하며, 자동차주행(自動車走行)에 의한 진동시험(振動試驗)에 의하면 상대적(相對的) 가속도(加速度)레벨의 크기는 회사장(灰捨場)의 경우가 자연지반(自然地盤)의 경우 보다 다소 크고 감쇠효과(減衰效果)는 적음을 알 수 있었다. 영동, 영월 저회(底灰)의 CBR은 77-137%가 되는 등 석탄회(石炭灰)는 동일입경의 일반흙에 비해 여러 가지 유리한 공학적(工學的) 특성(特性)을 갖고 있어서 앞으로 다소의 보완연구(補完硏究)가 이루어 지면 해안매립(海岸埋立) 성토재(盛土材) 및 도로보장재(道路輔裝材)는 물론 경량골재(經量骨材) 등 일반건설재(一般建設材)로서의 활용(活用)이 기대(期待)된다.

  • PDF

고층건물의 자연 진동실험 및 시스템판별 (Ambient Vibration Testing and System Identification for Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제16권3호
    • /
    • pp.23-33
    • /
    • 2012
  • 구조물의 특성치를 결정하기 위하여 18층 규모의 사무용 건물 3동에 대하여 자연진동 조건하에서 동적계측실험을 수행하였다. 대상건물은 기본적으로 보-기둥 골조시스템에 횡하중을 보다 효율적으로 지지하기 위하여 추가적으로 코아가 배치된 혼합 구조형식을 나타낸다. 매층 마다 측정한 일련의 진동기록으로부터 고유진동수, 모드형태 및 감쇠율 등과 같은 모달계수를 추출하기 위하여 최신 주파수- 및 시간영역-기반 응답의존 시스템판별법인 FDD, pLSCF 및 SSI를 적용하였다. 3방법에 의하여 추출한 결과는 대체로 일치하였으나, 초기 FE 해석결과와 비교하여 저차 3개 고유진동수는 대략 1.2~1.7배나 되는 단단한 거동을 나타냈다. 진동응답으로부터 추출된 값, 기준에서 제시하는 약산식 및 FE해석에 의하여 산정된 고유주기를 비교하여 보면, FE결과가 가장 유연한 거동을 예측하였으며, 높이를 변수로 하는 약산식이 추출된 값에 가장 근접한 결과를 나타냈다. 이러한 차이는 현재의 실험 추출치에는 콘크리트 균열 등과 같은 강성저감 요인을 포함하고 있지 않으며, 또한 FE 해석치는 비구조체 및 사용된 재료의 실제성능 등과 관련된 강성증가 요소를 포함하고 있지 않기 때문이다.

대형 공진주시험기의 개발 및 검증 (Development and Verification of a Large Scale Resonant Column Testing System)

  • 김남룡;하익수;신동훈;김민섭
    • 대한토목학회논문집
    • /
    • 제32권6C호
    • /
    • pp.295-304
    • /
    • 2012
  • 본 연구에서는 대형 지반구조물의 축조재료로 이용되는 대입경 조립재료의 동적 변형특성을 평가하기 위한 목적으로 국내 최대 규모의 대형 공진주시험시스템을 구축하였으며 그 성능 및 적용성을 검증하였다. 신규 시험기는 하단 고정, 상부 자유단에 코일-자석 시스템에 의한 가진 하중을 제어하는 전형적인 Stokoe 식 공진주시험 장치이며, 지름 200 mm, 높이 400 mm의 원주형 공시체에 대한 시험이 가능다. 시험기의 구동 및 계측 시스템은 굵은 자갈 이상의 조립재료에 대한 활용에 적합하도록 출력 및 정밀도를 확보하였으며, 고정밀의 제어 계측이 가능한 자동화 시스템으로 구성되었다. 공진주시험기의 동적응답특성 및 사용성을 검증하기 위한 방안으로 금속시편과 다수의 폴리우레탄 검증 시편을 이용하여 시험을 수행하였으며 타 시험기 또는 시험기법과의 비교를 통하여 정밀도를 평가하였다. 대형 시험기의 지반재료의 동적 변형특성 평가에 대한 신뢰성을 확인하기 위하여 동일한 사질토 시료에 대한 시험을 일반 공진주시험과 병행한 결과 공시체의 크기에 따른 효과가 일부 나타나지만 전반적으로 동일한 결과를 획득하였다. 최종적으로 댐 축조용 사력재료 시료에 대한 대형 공진주시험을 수행하였으며, 그 결과의 실효성을 확인하였다.