• Title/Summary/Keyword: Material characteristic

Search Result 2,965, Processing Time 0.031 seconds

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

Preparation of Functional Healthy Drinks by Acanthopanax senticosus Extracts (가시오가피를 이용한 기능성 건강음료의 제조)

  • Sung, Mi-Sun;Jung, Hoe-Yune;Choi, Jun-Hyeok;Lee, Sung-Cheol;Choi, Bo-Hwa;Park, Sung Sun
    • Journal of Life Science
    • /
    • v.24 no.9
    • /
    • pp.959-966
    • /
    • 2014
  • This study was carried out to develop a functional healthy drink using 60% ethanol of dried Acanthopanax senticosus stem extract (ASE). The preparation, physical activity, anti-oxidant activity, and sensory properties of ASE were investigated. The moisture, crude protein, crude lipid, and ash contents of dried ASE were $6.50{\pm}0.12%$, $5.89{\pm}0.16%$, $1.18{\pm}0.11%$, and $3.03{\pm}0.40%$ respectively. The 1,1-Diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity was $87.42{\pm}1.63%$ at 1/10 folds diluted ASE. In total, 40 male ICR mice were divided into five groups including the control (PBS), positive control (Red ginseng 200 mg/kg/day), and ASE-treated groups at doses of 35, 70, and 140 mg/kg/day for five weeks, respectively. ASE was administrated orally one time per day for five weeks before treadmill exercises, and normal and positive controls were fed PBS and red ginseng extract. In the treadmill test, ASE-treated mice (140 mg/kg/day) could run 1.4 times longer than the control mice. Healthy drinks were prepared with the addition of ASE at levels of 0.97% or 0.49% (A, B, and C type). Among the healthy drinks, the B type (ASE, 0.97%) was revealed to have the highest level of taste and overall acceptability through a sensory evaluation. The brix and pH of the ASE health drink (B type) were 14.9 and 4.51, respectively. These results indicated that the dried stem of Acanthopanax senticosus could be used as a functional material in the health drink industry.

A Study on the Changes of Landscape Perception for 'Bejing-Palgyeong(北京八景)' in China (중국 역대 북경팔경(北京八景)의 경관인식 변화에 대한 고찰)

  • Kwon, Ji-Young;Kim, Sung-Kyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • This study closely analyzed poems and paintings related to Beijing-Palgyeong, as well as ancient maps and ancient writings. Through the study, people who read this study can consider, Beijing-Palgyeong's the process of changing times, changing landscape perception, physical and symbolic landscape elements, structural analysis, national management relationships, and finally how it was localized as symbolic place. The view point of the Beijing-Palgyeong is distributed in four places, one outside and one inside the city. Outside of the capital city of Beijing-Palgyeong were concentrated in Seosan(西山) where the resting place of the emperor and the center of the landscape view of Beijing. The view point of Beijing-Palgyeong inside the capital city is located in two places in the royal palace's Imperial Garden and in two villages around the fortress. In other words, Beijing-Palgyeong was selected as a place closely related to the imperial family, emperor, and royal palace from the time of its initial creation. Since then, many scholars, including the emperor, have used it for national management through Won(元), Ming and Qing Dynasty, and it have become more and more characteristic of 'The capital city of eight scenic views'. The two places inside the capital city praised the Gods and Emperors in the same way. Outside the capital city, the two sites depict the comfortable lives of the people who are governed by the emperor and depicting the village landscape around the city. In the end, it can be seen that most of the Beijing-Palgyeong are related to imperial palaces and emperors. If you look at the physical landscape of Beijing-Palgyeong by element, it mainly contains the contents of national management and the emperor's eulogy. Qianlong Emperor established the Beijing-Palgyeong in 1751 through the construction of a monument. A four-character on the front of the monument, and inscribed with a seven-word written by the person on the back. It can be said that Qianlong Emperor's Beijing-Palgyeong were intended to show off the results of Manchurian rule through the material symbol of the monument. Beijing-Palgyeong have been transformed into a landmark, and modern people use it as an indicator of the Beijing-Palgyeong.

A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193 (국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구)

  • Hwang, Hyun Sung;Yun, Eun Young
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The Phoenix-shaped Glass Ewer, which is No. 193 National Treasure, was seriously damaged by a unique form of green glass pieces when excavated among a number of burial accessories of Hwangnamdaechong known to have been formed in the 5th century. While it has long been exhibited at the National Museum of Korea since its treatment for conservation treatment at conservation science laboratory in 1984, the existing adhesive materials seriously deteriorated for the 30 years, and the condition was quite unstable. The epoxy resin used as a restorative materials turned yellowing due to the light and heat so much that it was no longer able to exhibit it in a stable and effective manner. As a result, a re-treatment for conservation was conducted lately. This study focuses on the three pieces of Gold wires used to carefully wrap up the handle of the Phoenix-shaped Glass Ewer broken into three pieces, which has not been studied so far. As for the analysis method for Gold wires, SEM-EDS and Stereo Microscope were used for nondestructive analysis. First of all, the result of the SEM-EDS analysis shows that the composition was Au 91.9 wt.%-Au 92.8 w.t% and Ag 5.9 wt.%-Ag 6.5 wt.%, which indicates that it was an alloy made of Au and Ag. The production technique of Gold wires was also observed by means of optical microscopes. In general, Gold wires were manufactured by a drawing process in which a lump of gold was beaten or pulled out of a hole or by a process of twisting a gold plate. However, Gold wires separated from the handle of the Phoenix-shaped Glass Ewer did not involve any trace of twisting on the surface. Rather, fine vertical stripes were observed with the sections filled up. Hence, it is thought that this Ewer went through a drawing process and then was mended. As a result, no certain relation with the golden mending material used for the Phoenix-shaped Glass Ewer was verified. The findings above indicate that most of the existing researches on Gold wires recognized them, not as separate remains, but merely as a component of other golden remains. Thus, there has been little systematic study on the manufacturing techniques of Gold wires. The future study on Gold wires may verify the correlation between the Gold wires used to fix the handle of the Phoenix-shaped Glass Ewer, which is examined in this study, with that of golden remains in the Silla era.

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF

The Morphologic Changes by Immunosuppression after Heterotopic Transplantation of the Murine Cryopreserved Trachea: An Animal Model for Obliterative Bronchiolitis (이소 이식된 쥐 기관의 면역억제 및 초냉동 보관에 의한 형태학적 변화: 폐색성 모세기관지염의 연구를 위한 동물 실험 모델)

  • 이창하;성숙환;오미혜
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.215-223
    • /
    • 1999
  • Background: The replacement of the narrowed long-segment trachea with various prosthetic materials or tissue grafts remains a difficult and unsolved surgical problem. Homologous cryopreserved tracheal transplantation has been considered to treat the irreversibly-damaged organs, such as in the lung or heart transplantation and also to overcome the limited supply of donor organs. We examined the morphological changes and the immunosuppressive effects of the cryopreserved trachea after the heterotopic transplantation in the rats. Material and Method: Sixty tracheal segments harvested from 30 donor Wistar rats were heterotopically implanted into the peritoneal cavity of 20 recipient Wistar rats and 40 Sprague Dawley rats. The 60 recipient rats were divided into 6 groups(10 rats/ group). In groups I, II, and III, 30 tracheal segments were implanted immediately after the harvesting and in groups IV, V, and VI, the segments were implanted 28 days after the cryopreservation. Groups I and IV were Wistar syngeneic controls. Groups II and V were Sprague Dawley recipients receiving no immunosuppression and Groups III and VI, were Sprague Dawley recipients receiving immunosuppressive agents. At 28 days all rats were sacrificed and the tracheal segments were evaluated grossly and histologically. Result: Immunosuppression of the tracheal segments had a significant influence on the changes of the tracheal lumen and tracheal epithelial cells, irrespective of the cryopreservation of the trachea(p<0.001). In groups III and VI receiving immunosuppressive agents, the tracheal lumen was patent and the normal epithelial cells were observed, however in the other groups not receiving the immunosuppressive agents, there were almost luminal obliteration by the proliferation of the fibrous tissues and a loss of the epithelial cells, the findings were similar to those in the case of obliterative bronchiolitis after a lung and a heart-lung transplantation. Conclusion: With the appropriate immunosuppressive agents, the lumen and the respiratory epithelium of the transplanted tracheal segment were well preserved, even after the cryopreservation of the tracheal segment, which shows the possibility of the long-term preservation and homologous transplantation of the trachea. But fibroproliferative obliteration of the tracheal lumen and the loss of the normal respiratory epithelial cells, characteristic findings of obliterative bronchiolitis, were observed in the groups without the immunosuppression. This experiment using the rat trachea may be useful in studying the pathogenesis, treatment, and prevention of obliterative bronchiolitis after a lung and a heart-lung transplantation.

  • PDF

The Comparison of Characteristics of Korean, Chinese and Japanese Traditional Flower Arts Used in Royal Court Ceremonies (한국과 중국 및 일본의 궁중 전통 꽃꽂이 특징비교)

  • Hong, Hoon Ki;Lee, Jong Suk
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.2
    • /
    • pp.125-135
    • /
    • 2010
  • To discover the main characteristics of Korean traditional flower arrangement, they were compared with different articles and old paintings used in royal court ceremonies. The primary research involved principle of design. The times periods used were the Joseon Dynasty era of Korea, the Ming era of China, and the Edo eras of Japan. The result, which shows both the similarities and differences, of the research is summarized as follows. The similarities were that they all respect the features of nature, and their image expresses their creator's thinking. There was one technique, called 'Suje', in which a part of the stem is coming out from one branch. Also, each three eras preferred flowering trees and ornamental trees more than annuals or foliage plants. one of the differences was that korea used a simple number of materials. The work had volume and appeared mild by using a soft curved line which was repetitive and massive. The Joseon Dynasty era advanced a sense of beauty with artistic symmetry and balance. The work seemed soft and natural because of the little change in blank space, with almost no angle of line. The form had a characteristic preference of being taller than the typical Japanese arrangement. It appeared simple, calm, and rustic by using only one kind of material. In contrast, the Chinese style was gorgeous and displayed volume in a non-symmetrical tripodal form, which incorporated various colors and materials. Also, they avoided processing the materials in order to emphasize the original beauty of nature. Chinese flower arts did not become formalized because they did not consider the formality seriously the formal. The Japanese style was also gorgeous because it incorporated various materials and angles. It included an extreme technique in which an artificial line divided the blank space delicately. The line was both strong and delicate in an established form. The restriction of the main branch gave a light feeling, as well as more strain as in a balance sense. The Japanese eras emphasized more the use of line and a sense of blank space.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Classifications by Materials and Physical Characteristics for Neolithic Pottery from Jungsandong Site in Yeongjong Island, Korea (영종도 중산동 신석기시대 토기의 재료학적 분류와 물리적 특성)

  • Kim, Ran Hee;Lee, Chan Hee;Shin, Sook Chung
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.4
    • /
    • pp.122-147
    • /
    • 2017
  • The Jungsandong sites are distributed across quartz and mica schist formations in Precambrian, and weathering layers include large amounts of non-plastic minerals such as mica, quartz, felspar, amphibole, chlorite and so on, which form the ground of the site. Neolithic pottery from Jungsandong exhibits various brown colors, and black core is developed along the inner part for some samples, and sharp comb-pattern and hand pressure marks can be observed. Their non-plastic particles have various composition, size distribution, sorting and roundness, so they are classified into four types by their characteristic mineral compositions. I-type (feldspar pottery) is including feldspar as the pain component or mica and quartz. II-type (mica pottery) is the combination of chloritized mica, talc, tremolite and diopside. III-type (talc pottery) is with a very small amount of quartz and mica. IV-type (asbestos pottery) is containing tremolite and a very small amount of talc. The inner and outer colors of Jungsandong pottery are somewhat heterogeneous. I-type pottery group shows differences in red and yellow degree, depending on the content of feldspar, and is similar to III-type pottery. II-type is similar to IV-type, because its red degree is somewhat high. The soil of the site is higher in red and yellow degree than pottery from it. The magnetic susceptibility has very wide range of 0.088 to 7.360(${\times}10^{-3}$ SI unit), but is differentiated according to minerals, main components in each type. The ranges of bulk density and absorption ratio of pottery seem to be 1.6 to 1.7 and 13.1 to 26.0%, respectively. Each type of pottery shows distinct section difference, as porosity and absorption ratio increase in the order as follows: I-type (organic matter fixed sample) < III-type and IV-type < I-type < II-type (including IV-type of IJP-15). The reason is that differences in physical property occur according to kind and size of non-plastic particles. Although Jungsandong pottery consists of mixtures of various materials, the site pottery has a geological condition on which all mineral composition of Jungsandong pottery can be provided. There, it is thought that raw materials can be supplied from weathered zone of quartz and mica schist, around the site. However, different constituent minerals, size and rock fragments are shown, suggesting the possibility that there can be more raw material pits. Thus, it is estimated that there may be difference in clay and weathering degree.