• Title/Summary/Keyword: Matching performance

Search Result 1,784, Processing Time 0.027 seconds

A Study on the Present Condition of Four-Year University Curriculum for Introducing NCS Landscape Architecture (NCS 조경 분야 적용을 위한 4년제 대학 교육과정 현황분석)

  • Lee, Chang-Hun;Kim, Kyou-Sub;Lee, Won-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.134-147
    • /
    • 2019
  • The purpose of this study was to analyze the functional unit system of NCS landscape field for correction and supplementation of NCS landscape field and the contents of the four-year college landscape course subject. First, 24 unconsolidated four-year universities were selected, and FGI was conducted and verified for 816 courses in 24 universities. The results of the study are summarized as follows, with three sections three, nine divisions and 65 sub-category. First, landscape design subjects accounted for 40.0% of the subjects organized by four-year universities. In addition, the ratio of 12.9% for ecological landscape, 11.3% for landscape construction, 10.2% for others, 10.0% for landscape information, 6.6% for landscape culture and 3.7% for landscape management was surveyed. Balanced and efficient modification and reinforcement of NCS is required in the future. Second, 10(18.9%) units with matching NCS performance criteria and educational objectives were found to be capable of different units(18.9%), 15(28.3%), and 37subjects with inconsistent NCS unit capability (56.9%). Third, looking at the criteria for the reference of each unit of capability presented by the NCS, it is deemed that one unit of capability should be organized separately to improve the practical ability, since it includes the contents of basic knowledge learning. Fourth, the objectives pursued on the basis of the contents of the NCS capability unit and four-year college curriculum were developed by focusing on the development of unit capabilities in the field of landscape construction and landscape management compared to the field of landscape design. It has been shown that a balance is needed for future development. This study is intended to put forward further research that re-examine specific curriculum assessment criteria that have not been classified in the course of classifications based on the curriculum handbook, which excludes interferences from each school.

Longest First Binary Search on Prefix Length for IP Address Lookup (최장 길이 우선 검색에 기초한 프리픽스 길이에 따른 이진 IP 검색 구조)

  • Chu Ha-Neul;Lim Hye-Sook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.8B
    • /
    • pp.691-700
    • /
    • 2006
  • Based on the destination IP address of incoming packets, the Internet routers determine next hops and forward packets toward final destinations through If address lookup. The bandwidth of communication links increases exponentially fast as well as the routing table size grows significant as the number of single host networks attached to the Internet increases. Since packets should be processed at wire-speed, the increased link speed reduces the processing time of a packet in routers, and hence more efficient and fast IP address lookup algorithms and architectures are required in the next generation routers. Most of the previous IP lookup schemes compare routing prefixes of shorter length first with a given input IP address. Since IP address lookup needs to find the most specific route of the given input, search continues until the longest matched prefix is found while it keeps remembering the current test matching prefix. In this paper, based on binary search on prefix length, we proposed a new IP address lookup algorithm which compares longer prefixes first. The proposed scheme is consisted of multiple tries with prefixes on leaves only. The trie composed of the longest prefixes is primarily searched whether there is a match with the given input. This processing is repeated for the trio of the next longer prefixes until there finds a match. Hence the proposed algorithm provides the fast search speed. The proposed algorithm also provides the incremental update of prefixes while the previous binary search on length scheme does not provide the incremental update because of pre-processing requirement. In this paper, we performed extensive simulations and showed the performance comparisons with related works.

A Prospective Randomized Comparative Clinical Trial Comparing the Efficacy between Ondansetron and Metoclopramide for Prevention of Nausea and Vomiting in Patients Undergoing Fractionated Radiotherapy to the Abdominal Region (복부 방사선치료를 받는 환자에서 발생하는 오심 및 구토에 대한 온단세트론과 메토클로프라미드의 효과 : 제 3상 전향적 무작위 비교임상시험)

  • Park Hee Chul;Suh Chang Ok;Seong Jinsil;Cho Jae Ho;Lim John Jihoon;Park Won;Song Jae Seok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.127-135
    • /
    • 2001
  • Purpose : This study is a prospective randomized clinical trial comparing the efficacy and complication of anti-emetic drugs for prevention of nausea and vomiting after radiotherapy which has moderate emetogenic potential. The aim of this study was to investigate whether the anti-emetic efficacy of ondansetron $(Zofran^{\circledR})$ 8 mg bid dose (Group O) is better than the efficacy of metoclopramide 5 mg lid dose (Group M) in patients undergoing fractionated radiotherapy to the abdominal region. Materials and Methods : Study entry was restricted to those patients who met the following eligibility criteria: histologically confirmed malignant disease; no distant metastasis; performance status of not more than ECOG grade 2; no previous chemotherapy and radiotherapy. Between March 1997 and February 1998, 60 patients enrolled in this study. All patients signed a written statement of informed consent prior to enrollment. Blinding was maintained by dosing identical number of tablets including one dose of matching placebo for Group O. The extent of nausea, appetite loss, and the number of emetic episodes were recorded everyday using diary card. The mean score of nausea, appetite loss and the mean number of emetic episodes were obtained in a weekly interval. Results : Prescription error occurred in one patient. And diary cards have not returned in 3 patients due to premature refusal of treatment. Card from one patient was excluded from the analysis because she had a history of treatment for neurosis. As a result, the analysis consisted of 55 patients. Patient characteristics and radiotherapy characteristics were similar except mean age was $52.9{\pm}11.2$ in group M, $46.5{\pm}9.5$ in group O. The difference of age was statistically significant. The mean score of nausea, appetite loss and emetic episodes in a weekly interval was higher in group M than O. In group M, the symptoms were most significant at 5th week. In a panel data analysis using mixed procedure, treatment group was only significant factor detecting the difference of weekly score for all three symptoms. Ondansetron $(Zofran^{\circledR})$ 8 mg bid dose and metoclopramide 5 mg lid dose were well tolerated without significant side effects. There were no clinically important changes In vital signs or clinical laboratory parameters with either drug. Conclusion : Concerning the fact that patients with younger age have higher emetogenic potential, there are possibilities that age difference between two treatment groups lowered the statistical power of analysis. There were significant difference favoring ondansetron group with respect to the severity of nausea, vomiting and loss of appetite. We concluded that ondansetron is more effective anti-emetic agents in the control of radiotherapy-induced nausea, vomiting, loss of appetite without significant toxicity, compared with commonly used drug, i.e., metoclopramide. However, there were patients suffering emesis despite the administration of ondansetron. The possible strategies to improve the prevention and the treatment of radiotherapy-induced emesis must be further studied.

  • PDF

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.