• 제목/요약/키워드: Master Cam

검색결과 53건 처리시간 0.03초

국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험 (Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS))

  • 변태희;남민경;김정호;김부섭
    • 대한치과기공학회지
    • /
    • 제40권3호
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가 (Evaluation of validity of polyurethane model fabricated by intra-oral scanning method)

  • 김원태;이병기;현종구;김기백
    • 대한치과기공학회지
    • /
    • 제36권2호
    • /
    • pp.91-96
    • /
    • 2014
  • Purpose: The purpose of this study was evaluate the validity of polyurethane model fabricated by intra oral scanning method. Methods: Ten sam cases of stone models were manufactured from master model, and polyurethane models were made with the intra oral scanning and CNC milling method. One examiner individually measured 6 distances(intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) on the stone models and the polyurethane models. The Mann-Whitney U test(${\alpha}$=0.05) were used for statistical analysis. Results: The mean difference between measurements made directly on the stone models and those made on the polyurethane models was 0.31-0.38mm. No statistically differences between the two groups were founded 4 distances(p>0.05), but 2 distances were statistically significant(p<0.05). Conclusion: Stone models showed larger than polyurethane models fabricated by intra oral scanning method.

비진원 가공용 공구 이송장치의 고속화 성능에 관한 연구 (A Study on the High Speed of Cutting Tool Feed System for the Noncircular Machining)

  • 김성식
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.96-103
    • /
    • 1998
  • With the advance of processing technology , so as to spare fuel, piston heads used in automobile reciprocating engine have complex 3-dimension, with respect to shape such as ovality, profile, eccentricity, offset, recess. Therefore, coming out of the existing process work used master cam. the process work is performed using a CNC lathe. For a precision processing, the processing work is need to make study of high speed feed gear synchronized with the rotative speed of main spindle. And then the high speed feeding system must maintain high dynamic stiffness, high speed and high positioning accuracy . In this paper, in order to achieve high speed cutting tool feeding. The linear brushless DC motor is used for satisfying this process work. The ball bush and turicite is used as the guidance of the feed gear system. Also linear encoders, digital servo amplifiers and controller are used for controlling driving motor. This paper presents the design and simulation of the new tool feed system for noncircular machining.

  • PDF

CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구 (Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM)

  • 김서랑;김명주;박지만;김성균;허성주;곽재영
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.1-17
    • /
    • 2023
  • 목적: 본 연구의 목적은 레이져 신터링, 컴퓨터 밀링, 주조의 세 가지 방법으로 제작된 비귀금속 합금 코핑의 변연 형태에 따른 변연 적합도의 변화를 관찰하는 데 있다. 재료 및 방법: 서로 다른 두 개의 변연 형태를 정확히 재현하기 위해 3D Computer-aided Design을 이용하여 지대치 삭제의 원칙에 따라 지대치를 디자인한 다음, 티타늄 블럭을 컴퓨터 밀링하여 주모델을 제작하였다. 각각의 모델에 대하여 위의 3가지 제작 방식으로 비귀금속 합금 코핑을 12개씩 제작하여, 총 72개의 코핑을 제작하였다. 각 코핑은 지대치에 적합시켜서 공초점 레이저 주사 현미경으로 근심, 협측, 원심, 설측 변연의 변연 적합도를 150배율로 측정하였다. 결과: 레이져 신터링으로 제작한 코핑의 평균 변연 오차는 deep chamfer margin에서 11.8 ± 7.4 ㎛, rounded shoulder margin에서 6.3 ± 3.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P < .0001). 컴퓨터 밀링으로 제작한 그룹에서는 deep chamfer margin에서 53.9 ± 27.8 ㎛, rounded shoulder margin에서 48.6 ± 30.0 ㎛였고, 변연 형태에 따른 유의한 차이가 없었다 (P = .279). 주조 방법으로 제작한 그룹은 deep chamfer margin에서 18.8 ± 20.2 ㎛, rounded shoulder margin 에서 30 ± 20.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P = .0004). 결론: 이번 실험을 통하여, 다음과 같은 결론을 얻었다. 1. 변연의 형태에 따른 변연 적합도는 레이져 신터링이나 주조 방법으로 제작된 금속 코핑의 경우 변연 형태에 따라 유의한 차이가 있었다. 2. 레이져 신터링으로 제작한 금속 코핑에서 rounded shoulder margin이 deep chamfer margin보다 우수한 변연 적합도를 보였다. 3. 주조 방법으로 제작한 금속 코핑의 경우는 deep chamfer margin이 rounded shoulder margin보다 우수한 변연 적합도를 보였다. 4. 제작 방식에 따른 코핑의 변연 적합도는 레이져 신터링이 가장 양호하였고, 그 다음 주조 방법과 밀링 방법 순으로 변연 적합도 양호하였다. 이번 연구를 통해, 지대치의 변연 형태에 따른 금속 코핑의 변연 적합도의 변화를 관찰하였으며, 레이져 신터링으로 제작하거나 디지털 밀링한 왁스 패턴을 캐스팅한 경우에는 상관 관계가 있음을 확인하였다. 임상에 적용함에 있어 지대치의 변연 형태를 고려하여 제작 방식을 결정하는 것이 추천된다.

하악 제1대구치 상실 시 인접 및 대합 치아들의 이동양상에 따른 교합력 변화: 스트레인게이지를 이용한 비교 연구 (Changes in occlusal force depending on the movement of the adjacent and opposing teeth after loss of lower first molar: comparative study by using a strain gauge)

  • 송명자;박지만;전윤식
    • 구강회복응용과학지
    • /
    • 제32권1호
    • /
    • pp.47-59
    • /
    • 2016
  • 목적: 하악 제1대구치 상실 시 인접 및 대합 치아들의 경사 및 정출 정도에 따른 교합력의 변화를 스트레인게이지를 이용하여 측정 및 비교하는 것이다. 연구 재료 및 방법: 인접 및 대합 치아들의 경사 및 정출이 심화되는 정도를 점진적으로 네 개의 다이에 표현 후, CAD/CAM 제작 맞춤형 다이 시스템을 통하여 주모형에 부착 및 교체 가능하도록 하였다. 치아에 스트레인게이지를 부착 후, 만능물성시험기로 저작력을 가하면서 상하악 치아의 교합력을 측정하였다. 통계처리는 독립표본 t검증과 일원배치 분산분석을 시행하였다(${\alpha}=.05$). 결과: 대구치 상실 후 치아이동에 따른 교합력의 양상은, 네 단계의 모형에 대한 교합력의 차이가 통계적으로 유의하였고, 감소 추세였다. 음식물 저작 시 인접 치아들의 이동에 따라 상악 제1, 2소구치, 하악 제2대구치에서 점차 교합력이 감소되었다. 음식물의 경도가 감소함에 따라 치아의 교합력이 점차적으로 감소하였다. 육포 저작 시 하악 제2대구치의 교합력이 가장 높게 측정되었다(P < 0.05). 결론: 하악 제1대구치가 상실되고 치아 이동이 일어나기 전에는 저작 시 치아가 상실되지 않았을 때에 비해 인접 및 대합 치아들의 교합력이 높은 반면, 치아 이동이 진행됨에 따라 교합력은 정량적으로 감소하였다.

한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구 (THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS)

  • 김형섭;신상완
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

전부도재관의 변연 적합도 비교평가 (Comparative study in marginal accuracy of several all ceramic crowns)

  • 김정미;정수하
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.