• Title/Summary/Keyword: Mass size distribution

Search Result 389, Processing Time 0.03 seconds

The effect of the boss and mass on the sensitivity of the piezoresistive sensor (압저항 센서에서 보스와 매스가 센서 민감도에 미치는 영향)

  • Shim, Jae-Joon;Lee, Sung-Wook;Han, Dong-Seop;Kim, Tae-Hyung;Han, Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.405-410
    • /
    • 2005
  • In these days, the piezoresistive material has been applied to various sensors in order to measure the change of physical quantities. But the relationship between the sensitivity of a sensor and the position and size of piezoresistor has rarely been studied. Therefore, this paper was focused on the distribution of the resistance change ratio on the diaphragm and bridge surface where piezoresistor would be formed, and proposed the proper size and position of piezoresistor with which the sensitivity of sensor was increased. As the width of mass and boss was increased, the distance between piezoresistors was closed and the maximum value of resistance change ratio was decreased by the increase of the structure stiffness.

  • PDF

Investigation on the Sauter Mean Diameter of an Air-Assisted Fuel Injector -Operating Parameter Consideration (운전조건에 따른 공기보조 분사기의 Sauter 평균입경에 대한 고찰)

  • 장창수;최상민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.42-50
    • /
    • 2000
  • Drop size distribution of an air-assisted fuel injector(AAFI) was investigated. Influence of parameters such as ambient air density supply pressure and air-liquid mass ratio(ALR) was examined through both measurement and analysis. The Sauter mean diameter$D_{32}$ varied from 9 to 25$\mu$m throughout all experimental conditions. An empirical correlation for droplet size was obtained. Analytical correlations for predicting $D_{32}$ with respect to operating conditions were also derived through energy consideration and introduction of a simplified model of the from the empirical fitting was adapted to the original equation the proposed correlation in this study matched more closely with measured results. The current correlation exhibited a favorable study matched more closely with measured results. The current correlation exhibited a favorable prediction for $D_{32}$ compared to that by the empirical correlation at selected experimental conditions so that it may be used to predict atomization performance of the AAFI at operating conditions which was not covered in the measurements. After validation the analytical equation was applied to survey the feasible operating conditions for gasoline direct injection application.

  • PDF

Fabrication and Characterization of High-activity Pt/C Electrocatalysts for Oxygen Reduction

  • Lim, Bo-Rami;Kim, Joung-Woon;Hwang, Seung-Jun;Yoo, Sung-Jong;Cho, Eun-Ae;Lim, Tae-Hoon;Kim, Soo-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1577-1582
    • /
    • 2010
  • A 20 wt % Pt/C is fabricated and characterized for use as the cathode catalyst in a polymer electrolyte membrane fuel cell (PEMFC). By using the polyol method, the fabrication process is optimized by modifying the carbon addition sequence and precursor mixing conditions. The crystallographic structure, particle size, dispersion, and activity toward oxygen reduction of the as-prepared catalysts are compared with those of commercial Pt/C catalysts. The most effective catalyst is obtained by ultrasonic treatment of ethylene glycol-carbon mixture and immediate mixing of this mixture with a Pt precursor at the beginning of the synthesis. The catalyst exhibits very uniform particle size distribution without agglomeration. The mass activities of the as-prepared catalyst are 13.4 mA/$mg_{Pt}$ and 51.0 mA/$mg_{Pt}$ at 0.9 V and 0.85 V, respectively, which are about 1.7 times higher than those of commercial catalysts.

Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC) (광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성)

  • Jung Chang-Hoon;Cho Yong-Sung;Lee Jong-Tae
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

Atmospheric Concentration and Size Distribution of Airborne Particulates, Benzopyrene and Heavy Metals (대기(大氣) 중 Benzopyrene 및 중금속(重金屬)의 농도(濃度)와 입경분포(粒徑分布))

  • Heo, Moon-Young;Kweon, Chang-Ho;Yu, Ki-Seon;Choi, Seong-Kyu;Kweon, Chang-Ho;Kim, Kyeong-Ho;Sohn, Dong-Hun
    • YAKHAK HOEJI
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 1990
  • Total suspended particulate (TSP) in the atmosphere was collected and size-fractionated by Andersen high volume air sampler for the past two years (Mar. 1987-Feb. 1989) in Seoul. The concentrations of several polycyclic aromatic hydrocarbons and heavy metals were determined to investigate the atmospheric concentrations, seasonal variations and its relationship with the size distribution of suspended particulate matter. The arithmetic mean concentration of total suspended particulate was $229.48\;{\mu}g/m^3$. The concentrations of heavy metals were $2971.94\;ng/m^3$ for Fe, $767.75\;ng/m^3$ for Zn, $765.80\;ng/m^3$ for Pb, $218.40\;ng/m^3$ for Cu, $129.91\;ng/m^3$ for Mn, respectively. And the concentration of PAHs were $3.23\;ng/m^3$ for benzo(a)pyrene, $2.71\;ng/m^3$ for benzo(k)fluoranthene, $4.53\;ng/m^3$ for benzo(ghi)perylene, respectively. The mass-size distribution of TSP was lowest in the particle size range $1.1-3.3\;{\mu}m$ increased as the particle size increased or decreased. But PAHs, Pb and Zn abounded in particles below $2.0\;{\mu}m$, while Fe and Mn abouned in particles above $2.0\;{\mu}m$. TSP and its chemical compositions showed the seasonal variations. The concentrations of anthrophogenic origin like TSP, PAH and heavy metals in the fine particles were highest in winter and lowest in summer. PAH and Ph analyzed showed significant correlations with each other and with TSP concentration in fine particles, indicating that the particles in which they are contained have a similar behavior in the atmosphere.

  • PDF

A Study on the Quantified Criteria in Determining the Geostructural Domain of Fractured Rock Mass (절리암반내 지구조구 설정을 위한 정량적 기준에 대한 연구)

  • Um Jeong-Gi;Cho Taechin;Kwon Soon Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.1 s.60
    • /
    • pp.26-37
    • /
    • 2006
  • This study addresses the applicability of box fractal dimension, $D_B$, as an index of statistical homogeneity of fractured rock mass. The box-count method's capability in quantifying the combined effect of fracture density and size distribution is examined systematically. Total of 129 two-dimensional fracture configurations were generated based on different combinations of fracture size distribution and fracture density. $D_B$was calculated for the generated fracture network systems using the box-counting method. It was found that was standard deviation of trace length and fracture orientation have no effect on calculated $D_B$. The estimated $D_B$ was found to increase with increasing total density and/or mean trace length. To explore the field applicability of this study, the statistical homogeneity of fractured rock mass was investigated at the rock slope and the underground facility using the box-counting method as well as conventional contingency table analysis. The results obtained in this study clearly show that the methodologies given in this paper have the capability of determining the statistical homogeneity of fractured rock mass.

Myocardial atrophy in children with mitochondrial disease and Duchenne muscular dystrophy

  • Lee, Tae Ho;Eun, Lucy Youngmin;Choi, Jae Young;Kwon, Hye Eun;Lee, Young-Mock;Kim, Heung Dong;Kang, Seong-Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.5
    • /
    • pp.232-239
    • /
    • 2014
  • Purpose: Mitochondrial disease (MD) and Duchenne muscular dystrophy (DMD) are often associated with cardiomyopathy, but the myocardial variability has not been isolated to a specific characteristic. We evaluated the left ventricular (LV) mass by echocardiography to identify the general distribution and functional changes of the myocardium in patients with MD or DMD. Methods: We retrospectively evaluated the echocardiographic data of 90 children with MD and 42 with DMD. Using two-dimensional echocardiography, including time-motion (M) mode and Doppler measurements, we estimated the LV mass, ratio of early to late mitral filling velocities (E/A), ratio of early mitral filling velocity to early diastolic mitral annular velocity (E/Ea), stroke volume, and cardiac output. A "z score" was generated using the lambda-mu-sigma method to standardize the LV mass with respect to body size. Results: The LV mass-for-height z scores were significantly below normal in children with MD ($-1.02{\pm}1.52$, P<0.001) or DMD ($-0.82{\pm}1.61$, P =0.002), as were the LV mass-for-lean body-mass z scores. The body mass index (BMI)-for-age z scores were far below normal and were directly proportional to the LV mass-for-height z scores in both patients with MD (R =0.377, P<0.001) and those with DMD (R =0.330, P=0.033). The LV mass-for-height z score correlated positively with the stroke volume index (R =0.462, P<0.001) and cardiac index (R =0.358, P<0.001). Conclusion: LV myocardial atrophy is present in patients with MD and those with DMD and may be closely associated with low BMI. The insufficient LV mass for body size might indicate deterioration of systolic function in these patients.

Welding Fume and Others from Welding Processes

  • Yoon, Chung-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.4
    • /
    • pp.320-328
    • /
    • 2004
  • A number of health hazards are generated in welding processes. In this paper, the characteristics of fumes and some other hazardous agents in welding are reviewed. Fumes in welding are generated by complex mechanism like physical ejection of particles, oxidation-enhanced vaporization, vaporization-condensation-oxidation, and spatter contribution. Fume generation rates could be described as a power function in a given process. Most of fume constituents was originated from consumables rather than base metal. The mass distribution for the welding fumes is unimodal and very small to penetrate respiratory system. So, almost fractions of fumes are classified into the respirable particulate mass. Total chromium contents in FCAW were similar to those from SMAW whereas hexavalent chromium concentrations in fume were similar to those produced from MIG welding fume. Hexavalent chromium was mostly soluble which was similar to the characteristic solubility of fume hexavalent chromium from SMAW.

The Study of DAF-System to Apply the CSOs Treatment (CSOs의 오염물질 제거시 DAF-system의 적용에 관한 연구)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.385-391
    • /
    • 2004
  • This paper examines the applicability of DAF-system to the domestic sewers for the effective CSOs treatment. The procedures for the experiment include mainly two steps. One is to analyse the water qualities and settling test of the CSOs and the other focuses on general characteristics of the CSOs such as the removal efficiency of pollutant, the distribution of particle size and mass balance of DAF-system. The result of this study show that the application of DAF-system is more effective and economical than the existing treatment systems because it has two removal mechanisms of sedimentation and flotation simultaneously.

Three-Dimensional Modelling and Sensitivity Analysis for the Stability Assessment of Deep Underground Repository

  • Kwon, S.;Park, J.H.;Park, J.W.;Kang, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.605-618
    • /
    • 2001
  • For the mechanical stability assessment of a deep underground high-level waste repository. computer simulations using FLAC3D were carried out and important parameters including stress ratio, depth, tunnel size, joint spacing, and joint properties were chosen from sensitivity analysis. The main effect as well as the interaction effect between the important parameters could be investigated effectively using fractional factorial design . In order to analyze the stability of the disposal tunnel and deposition hole in a discontinuous rock mass, different modelings were performed under different conditions using 3DEC and the influence of joint distribution and properties, rock properties and stress ratio could be determined. From the three dimensional modelings, it was concluded that the conceptual repository design was mechanically stable even in a discontinuous rock mass.

  • PDF