• 제목/요약/키워드: Mass aerosol

검색결과 282건 처리시간 0.023초

A study on transport and plugging of sodium aerosol in leak paths of concrete blocks

  • Sujatha Pavan Narayanam;Soubhadra Sen;Kalpana Kumari;Amit Kumar;Usha Pujala;V. Subramanian;S. Chandrasekharan;R. Preetha;B. Venkatraman
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.132-140
    • /
    • 2024
  • In the event of a severe accident in Sodium Cooled Fast Reactors (SFR), the sodium combustion aerosols along with fission product aerosols would migrate to the environment through leak paths of the Reactor Containment Building (RCB) concrete wall under positive pressure. Understanding the characteristics of sodium aerosol transport through concrete leak paths is important as it governs the environmental source term. In this context, experiments are conducted to study the influence of various parameters like pressure, initial mass concentration, leak path diameter, humidity etc., on the transport and deposition of sodium aerosols in straight leak paths of concrete. The leak paths in concrete specimens are prepared by casting and the diameter of the leak path is measured using thermography technique. Aerosol transport experiments are conducted to measure the transported and plugged aerosol mass in the leak paths and corresponding plugging times. The values of differential pressure, aerosol concentration and relative humidity taken for the study are in the ranges 10-15 kPa, 0.65-3.04 g/m3 and 30-90% respectively. These observations are numerically simulated using 1-Dimensional transport equation. The simulated values are compared with the experimental results and reasonable agreement among them is observed. From the safety assessment view of reactor, the approach presented here is conservative as it is with straight leak paths.

수원지역 입자상 오염물질의 오염원 기여도의 추정 (Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area)

  • 이태정;김동술
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF

에어로솔 입자의 정밀입경분포 측정을 위한 물분자 클러스터 이온의 질량예측 (Mass Prediction of Various Water Cluster Ions for an Accurate Measurement of Aerosol Particle Size Distribution)

  • 정종환;이혜문;송동근;김태오
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.752-759
    • /
    • 2007
  • For an accurate measurement of aerosol particle size distribution using a differential mobility analyser (DMA), a new calculation process, capable of predicting the masses for the various kinds of water cluster ions generated from a bipolar ionizer, was prepared by improving the previous process. The masses for the 5 kinds of positive and negative water cluster ions produced from a SMAC ionizer were predicted by the improved calculation process. The aerosol particle charging ratios calculated by applying the predicted ion masses to particle charging equations were in good accordance with the experimentally measured ones, indicating that the improved calculation process are more reasonable than the previous one in a mass prediction of bipolar water cluster ions.

2008년 동아시아 대륙으로부터 기원이 다른 먼지와 인위적 오염 입자의 광역적 이동 사례에 대한 분석 (An Analysis on the Episodes of Large-scale Transport of Natural Airborne Particles and Anthropogenically Affected Particles from Different Sources in the East Asian Continent in 2008)

  • 김학성;윤마병;손정주
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.600-607
    • /
    • 2010
  • 2008년 동아시아 대륙에서 발생기원이 다른 먼지(황사)와 인위적 오염입자의 광역적 이동 사례를 NOAA위성 RGB 합성영상과 지상 입경별 분진(TSP, $PM_{10}$, $PM_{2.5}$)의 질량농도 관측으로 분석하였다. 또한 Terra/Aqua 위성 MODIS(Moderate resolution Imaging Spectroradiometer) 센서의 AOD(Aerosol Optical Depth)와 FW(Fine aerosol Weighting)를 통해 동아시아 지역에서 발생기원이 다른 대기 에어로졸의 분포와 입자 크기 특성을 분석하였다. 중국 북부와 몽골, 그리고 중국 황토고원에서 모래폭풍이 발생하여 광역적으로 이동하여 청원에 먼지입자(황사)로 영향을 주는 6 개의 사례분석을 실시하였다. 질량농도 TSP중 $PM_{10}$은 70%, $PM_{2.5}$는 16%로 조대입자(> $2.5\;{\mu}m$)의 비율이 큰 것은 사막과 반사막의 자연적 발생원에서 생성되었기 때문이다. 그러나, 모래 폭풍이 이동 과정에서 중국 동부의 산업 지역을 거쳐 유입하는 사례에서는 TSP 중 $PM_{2.5}$가 23%까지 증가하기도 했다. 중국 동부로부터 황해를 거쳐 한반도로 유입한 5개 다른 사례의 경우, TSP 중 $PM_{10}$, $PM_{2.5}$가 각각 82, 65%로 나타났다. 이와 같이 $PM_{2.5}$의 상대적 비율이 증가한 것은 인위적 오염입자의 영향 때문이다. 동아시아 지역에서 인위적 오염입자의 광역적 이동 사례에 대한 평균 AOD는 $0.42{\pm}0.17$로 황사에 의한 AOD($0.36{\pm}0.13$)와 비교하여 대기 에어로졸에 대한 비율이 높게 나타났다. 특히, 중국 동부에서 황해, 한반도, 동해에 이르는 광역적 지역에 AOD값이 높게 분포했다. 인위적 오염입자의 사례는 FW가 평균 $0.63{\pm}0.16$로 모래폭풍의 이동 사례의 $0.52{\pm}0.13$ 보다 높은 값을 보였다. 이는 대기 에어로졸에 대한 인위적 미세 오염 입자의 기여도가 클 수 있음을 제시하고 있다.

UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사 (Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions)

  • 최원이;이한림;최철웅;이양원;노영민
    • 대한원격탐사학회지
    • /
    • 제36권2_1호
    • /
    • pp.155-165
    • /
    • 2020
  • 본 연구에서는 복사전달모델을 사용하여 다양한 변수환경(파장 (340 nm, 477 nm), 에어로솔 종류(스모크, 황사, 황산염), AOD (aerosol optical depth), 지표면 반사도, 관측기하)에 따라 에어로솔 유효 고도(aerosol peak height; APH)에 대한 O4 대기질량인자(air mass factor; AMF)의 민감도를 조사하였다. 전반적으로, 477 nm의 O4 AMF 가 340 nm 보다 APH에 대한 민감도가 크고 안정적으로 산출 가능한 것으로 확인하였다. AOD가 높을 때 APH에 대한 O4 AMF의 민감도가 커지는 것을 확인하였다. 477 nm에서는 340 nm 보다 지표면 반사도의 영향이 큰 것으로 나타났다. 태양천정각 증가에 따라 340 nm에서의 O4 AMF가 감소하는 추세를 발견하였으며, 이러한 경향은 태양천정각 40°인 환경에서 높은 Rayleigh 및 Mie 산란에 의한 장벽효과로 인해 O4 흡수가 발생하는 광경로 길이가 줄어들기 때문인 것으로 사료된다. 477 nm에서는 태양천정각이 증가함에 따라 Rayleigh 및 Mie 산란에 의한 다중산란이 일부 발생하여 O4 AMF가 비선형함수 형태로 증가하는 경향을 보였다. 마지막으로, AOD의 불확실성이 APH 산출오차에 미치는 영향을 조사하였다. 황산염 타입에 대한 APH 산출 시, AOD의 불확실성으로 인한APH 산출오차가 다른 에어로솔 타입보다 크게 나타났으며, 황사의 경우 AOD 불확실성에 대한 APH 산출오차에 대한 영향이 미미하게 나타났다. 이러한 결과는 각 에어로솔 타입의 흡수 산란 특성이 다양하기 때문에, 에어로솔 타입이 APH 산출 오차에 영향을 미칠 수 있음을 의미한다.

OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포 (Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001)

  • 정창훈;전영신;최병철
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

미세먼지 간이측정기 현장 검사용 시험 입자 발생기 개발 및 성능 평가 (Development and performance evaluation of a test particle generator for a field inspection equipment of PM-2.5 sensors)

  • 정혁;박진수
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.61-68
    • /
    • 2022
  • In this study, a fluidized bed particle generator was developed to generate an aerosol without supply of compressed air and to increase portability. It was assumed that the mixing ratio of the test particles and beads, the input amount, and the air flow rate supplied to the generator would have effect on the aerosol generation characteristics. The product of these three parameters was set as a characteristic parameter and particle generation characteristics according to the change of the characteristic parameter were observed. As a result, it was confirmed that the input amount of test particles and beads was not suitable as a characteristic parameter and a characteristic parameter expressed as a product of the mass mixing ratio and the air flowrate was newly defined. When the new characteristic parameter is applied, it can be confirmed that the total amount of particles generated from the particle generator is a function of the characteristic parameter. As a result of measuring the amount of particle generation by adjusting the characteristic parameter, it was confirmed that the performance required for the test particle generator for the field inspection equipment of PM-2.5 sensors could be satisfied.

제주시 지역 미세먼지의 변동과 화학적 구성 특성 (Chemical Mass Composition of Ambient Aerosol over Jeju City)

  • 이기호;김수미;김길성;허철구
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.495-506
    • /
    • 2020
  • This study investigated the nitrate formation process, and mass closure of Particulate Matter (PM) were calculated over the urbanized area of Jeju Island. The data for eight water-soluble inorganic ions and nineteen elements in PM2.5 and PM10 were used. The results show that the nitrate concentration increased as excess ammonium increased in ammonium-rich samples. Furthermore, nitrate formation was not as important in ammonium-poor samples as it was in previous studies. According to the sum of the measured species, approximately 45~53% of gravimetric mass of PM remained unidentified. To calculate the mass closure for both PM2.5 and PM10, PM chemical components were categorized into secondary inorganic aerosol, crustal matter, sea salt, trace matter and unidentified matter. The results by the mass reconstruction of PM components show that the portion of unidentified matter was decreased from 52.7% to 44.0% in PM2.5 and from 45.1% to 29.1% in PM10, despite the exclusion of organic matter and elemental carbon.

서해안 안흥에서 관측된 에어로솔의 농도 변화 및 크기분포 특성 (Characteristics of Aerosol Mass Concentrations and Size Distribution Measured at Anheung, Korea)

  • 이권호;이규태;김정호;문관호;안준모
    • 한국대기환경학회지
    • /
    • 제34권5호
    • /
    • pp.677-686
    • /
    • 2018
  • An intensive measurement was conducted to study the mass and number concentrations of atmospheric aerosols in Anheung ($36.679^{\circ}N$, $126.186^{\circ}E$), the west coastal measurement site of Korea during December 2017~April 2018. To evaluate relationships between the aerosols and meteorological parameters, comparisons of Optical Particle Counter (OPC) measured data and Auto Weather System (AWS) data were performed. Measured PM mass concentrations are $PM_{10}=42.814{\pm}30.103{\mu}g/m^3$, $PM_{2.5}=29.674{\pm}25.063{\mu}g/m^3$, $PM_1=28.958{\pm}24.658{\mu}g/m^3$, respectively. The PM ratios showed that the $PM_{10}$ concentrations contained about 67.8% of $PM_{2.5}$, while most part of $PM_{2.5}$ was $PM_1$ (about 97.1%). Timely collocation with AWS data were performed, exploring relations with the PM concentrations. PM concentrations can be explained by wind direction and relative humidity conditions. The significant reductions of fine particles in mass and number concentrations may attribute to actions on particle growth and wet removal. In these results, we suppose that the aerosol concentrations and size distributions are affected by inflow direction and air mass sources from the origin.

원형관 코팅장치에서 연소 입자의 응축성장에 미치는 2차원 열 및 물질전달의 영향 (Effects of Two-dimensional Heat and Mass Transports on Condensational Growth of Soot Particles in a Tubular Coater)

  • 박성훈
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.163-171
    • /
    • 2013
  • Soot particles emitted from combustion processes are often coated by non-absorbing organic materials, which enhance the global warming effect of soot particles. It is of importance to study the condensation characteristics of soot particles experimentally and theoretically to reduce the uncertainty of the climate impact of soot particles. In this study, the condensational growth of soot particles in a tubular coater was modeled by a one-dimensional (1D) plug flow model and a two-dimensional (2D) laminar flow model. The effects of 2D heat and mass transports on the predicted particle growth were investigated. The temperature and coating material vapor concentration distributions in radial direction, which the 1D model could not accounted for, affected substantially the particle growth in the coater. Under the simulated conditions, the differences between the temperatures and vapor concentrations near the wall and at the tube center were large. The neglect of these variations by the 1D model resulted in a large error in modeling the mass transfer and aerosol dynamics occurring in the coater. The 1D model predicted the average temperature and vapor concentration quite accurately but overestimated the average diameter of the growing particles considerably. At the outermost grid, at which condensation begins earliest due to the lowest temperature and saturation vapor concentration, condensing vapor was exhausted rapidly because of the competition between condensations on the wall and on the particle surface, decreasing the growth rate. At the center of the tube, on the other hand, the growth rate was low due to high temperature and saturation vapor concentration. The effects of Brownian diffusion and thermophoresis were not high enough to transport the coating material vapor quickly from the tube center to the wall. The 1D model based on perfect radial mixing could not take into account this phenomenon, resulting in a much higher growth rate than what the 2D model predicted. The result of this study indicates that contrary to a previous report for a thermodenuder, 2D heat and mass transports must be taken into account to model accurately the condensational particle growth in a coater.