Development of Mass Transfer Models for Ammonia Flux Estimation from Sewage Treatment Plants (하수처리장에서의 암모니아 플럭스 산정을 위한 물질전달모형 개발)

  • Sa, Jae-Hwan;Jeon, Eui-Chan;Jeong, Jae-Hak
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.701-711
    • /
    • 2006
  • Sewage treatment plants located near to large cities emit extremely higher concentration of odorous materials. This study evaluated flux profiles of ammonia emitted from the water surface of sewage treatment plants using a dynamic flux chamber. Also, an ammonia overall mass transfer coefficient and a mass transfer model was developed in order to estimate fluxes of ammonia using environment parameters and the flux from the sewage treatment plants. The developed mass transfer model was evaluated through a fitness analysis. Comparison modeled flux applying empirical overall mass transfer coefficients of ammonia and measured ammonia flux show a high linearity with 0.977. The flux ratio of 1.282 demonstrated highly statistical fitness, also. Modeled flux using the mass transfer model was compared with measured flux. In result, it indicated that empirical overall mass transfer coefficients were similar to measured flux. The mass transfer model using the empirical overall mass transfer coefficient developed in this study was proved to be an easy and effective method to make accurate and precise predictions for ammonia flux discharged from sewage treatment plants.

A Study on Relation between the Fuel Mass Flux and the Oxidizer Mass Flux with the Initial Port Diameter in Hybrid Rocket (하이브리드 로켓에서의 초기 포트직경을 고려한 산화제 유속과 고체연료 유속과의 관계에 관한 연구)

  • Lee, Jung-Pyo;Cho, Sung-Bong;Yoon, Sang-Kyu;Park, Su-Hayng;Song, Na-Young;Kim, Gi-Hun;Cho, Jung-Tae;Sung, Hong-Gye;Moon, Hee-Jang;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.243-247
    • /
    • 2007
  • Fuel mass flux was experienced with a function of the oxidizer mass flux using initial port area of solid fuel, in stead of regression rate correlation which shows combustion characteristic in hybrid propulsion. The burning rate could be easily obtained by using the oxidizer mass flux of initial port area without iteration, and fuel configuration could be designed simply. In this experiments PE was used as fuel, COX was used as oxidizer. A variation of mass flux of solid fuel with port area is considered by changing the burning time. In the case of approximate 0.5 for an exponent of oxidizer mass flux, using the fuel mass flux correlation is more suitable than regression rate correlation in hybrid propulsion.

  • PDF

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

Characteristics of T-phase flow distribution and pressure drop in a horizontal T-type evaporator tube (수평 T형 증발관내 2상류의 유량분배 및 압력강하 특성)

  • 박종훈;조금남;조홍기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.658-668
    • /
    • 1999
  • The objective of the present study is to investigate the effect of experimental parameters on the hydrodynamic characteristics in a horizontal tee-type evaporator using R-22. The experimental apparatus consisted of an unheated tee-type test section, a liquid-vapor separator, a preheated, mass flow meters, a plate heat exchanger, pump, and other measurement devices. The experimental parameters were mass flux(500 and 600kg/$m^2$s), inlet quality(0.1~0.3) and separation ratio(0.3~0.7). Absolute pressure at the inlet of the test section was 0.652 MPa. The branch-to-inlet inner diameter ratio was 0.61. Pressure gradient at the branch section was larger than that at the run section at the same separation ratio. Pressure drop per unit length increased at the run section and decreased at the branch section as the separation ratio increased. Pressure drop predicted by the separated flow model agreed with experimental data within -35 to +16%. Generally, predicted values showed similar trend with the data. Mass flow ratio of vapor refrigerant was affected by the inlet quality more than the mass flux.

  • PDF

A study on condensation heat transfer performance in microchannel tube (마이크로 채널 관에서의 응축 열전달 성능에 관한 연구)

  • Lee, Jeong-Kun
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.22-29
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer by using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat transfer coefficient. The condensation heat transfer coefficient showed an increase as the vapor quality and mass flux increased. However, each tube shows little differences compared to 400kg/m2s or identical in case the mass flux are 200kg/m2s and 100kg/m2s. The major reason for these factors is increase-decrease of heat transfer area that the flux type of refrigerant is exposed to the coolant's vapor with the effect of channel aspect ratio or micro-fin. In addition, the heat transfer coefficient was unrelated to the heat flux, and shows a rise as the saturation temperature gets lower, an effect that occurs from enhanced density. The physical factor of heat transfer coefficient increased as the channel's aspect ratio decreased. Additionally, the micro pin at the multi-channel type tube is decided as a disadvantageous factor to condensation heat enhancement factor. That is, due to the effect of aspect ratio or micro-fin, the increase-decrease of heat transfer area that the flux type of a refrigerant is exposed to the vapor is an important factor.

Design of Multi-stack Axial Flux Permanent Magnet Synchronous Generator Considering Electromagnetic and Mechanical Characteristics (전자기 및 기계적 특성을 고려한 다중 적층형 AFPMSG의 설계)

  • Syed, Qurban Ali Shah;You, Young-Min;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1043-1044
    • /
    • 2011
  • This paper discusses the electromagnetic and mechanical design considerations to improve the design accuracy and power to mass ratio of multi-stack axial flux permanent magnet synchronous generator (AFPMSG). Design accuracy of multi-stack AFPMSG for direct drive wind turbine application is improved by considering magnetic flux leakages and fringing effect. FEM structural analysis is utilized to increase power to mass ratio of three-stack AFPMSG by reducing the rotor yoke thickness considering magnetic and centrifugal forces and Von Mises stress distribution.

  • PDF

Flow and Heat Transfer Measurements of Film Injectant from a Row of Holes with Compound Angle Orientations

  • Bumsoo Han;Sohn, Dong-Kee;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1137-1146
    • /
    • 2002
  • An experiment has been conducted on the flow and heat transfer characteristics of film coolant injected from a row of five holes with compound angle orientations of 35$^{\circ}$ inclination angle and 45$^{\circ}$ orientation angle. The Reynolds number based on the mainstream velocity and injection hole diameter 3.58${\times}$10$^4$. Three-dimensional velocity, film cooling effectiveness and heat transfer coefficient data are presented at three different mass flux ratios of 0.5, 1.0 and 2.0. Flow entrainment has been found between the vortices generated by adjacent injectants. The injectant with compound angle orientation entrains not only the mainstream boundary layer flow but also the adjacent injectant. Because of the flow entrainment, the injectant. With compound angle orientation is characterized by a single vortex while two bound vortices are usually observed in the case of simple angle injection. The strength of the secondary flow depends strongly on the mass flux ratio, which shows significant influence on the film cooling effectiveness and heat transfer coefficient.

Film cooling Effects on Wall Heat Flux of a Subscale Calorimetric Combustion Chamber (막냉각량에 따른 축소형 칼로리미터의 열유속 특성에 관한 연구)

  • Kim, Jong-Gyu;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Kim, Hong-Jip;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.93-99
    • /
    • 2006
  • The effects of the changes of a film cooling mass flow rate and operating conditions on wall heat flux characteristics of a subscale calorimetric combustion chamber were investigated by experiment and numerical analysis. At the nominal operating condition, with the film cooling mass flow rate being 10.5 percent of a main fuel mass flow rate, maximum heat flux at the nozzle throat was measured to be 30 percent lower than that without the film cooling. For the relatively higher mixture ratio and chamber pressure condition, maximum heat flux at the nozzle throat was increased by 31 percent compared to that of the nominal condition test without film cooling.

Two-phase Flow Characteristics of Refrigerant in T-branch with Horizontal and Vertical Inlet Tube (T형 수평 및 수직 입구 분지관 내 냉매 2상 유동 특성)

  • 태상진;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.741-748
    • /
    • 2002
  • The present study investigated the two-phase flow characteristics of refrigerant R-22 in T-branch with horizontal and vertical inlet tube The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), inlet mass flux (200~500 kg/$m^2$s) and inlet quality (0.1~0.4). Predicted pressure profile agreed with the measured data within 25.4%. The flow distribution ratio decreased as the mass flux increased. The flow distribution ratio decreased by 12~25% as the tube diameter ratio decreased from 1 to 0.61, and decreased by 38~47% as the orientation of branch changed from horizontal to vertical upward for horizontal inlet tubes. As the orientation of inlet tube changed from horizontal to vertical upward for horizontal branch, the flow distribution ratio increased by 15~68%, but the quality in the branch tube decreased by 28~92% due to phase separation.

Fuel Rich Gas O/F Ratio Characteristics of HDPE and Paraffin Fuel in Low Range of the Oxidizer Mass Flux (저 산화제유속 구간에서의 HDPE 및 Paraffin 연료의 연료농후가스 O/F비 특성)

  • Han, Seongjoo;Ryu, Sunghoon;Kim, Jinkon;Kang, Teagon;Moon, Heejang;Kim, Junhyung;Ko, Seung Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.6
    • /
    • pp.54-60
    • /
    • 2016
  • Multi-port HDPE and Paraffin firing tests are conducted for hybrid gas generator application of a ducted rocket in the low oxidizer mass flux range. A fuel rich gas of O/F ratio from 0.3 to 0.8, a typical O/F operating range of a ducted rocket gas generator, have been achieved with paraffin fuel implying that the hybrid system can be a potential candidate. It was also found that an almost constant O/F ratio regime exists under $35kg/m^2s$ of the oxidizer mass flux, opening a possibility for the paraffin fuel toward the VFDR gas generator application.