• Title/Summary/Keyword: Mass Disaster

Search Result 231, Processing Time 0.034 seconds

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

The Stability Analysis of Near Parallel Tunnels Pillar at Multi-layered Soil with Shallow Depth by Numerical Analysis (수치해석에 의한 저토피 다층지반에서 근접 병설터널 필라의 안정성 분석)

  • Lim, Hyungmin;Son, Kwangrok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.53-62
    • /
    • 2014
  • In Korea, in general, separation distance between existing parallel tunnels was set at two to five times as distant as the diameter of the tunnels according to ground conditions. Recently, however, actual applicability of closely spaced parallel tunnels whose distance between tunnel centers was shorter than the diameter has increased due to environmental damages resulting from massive cutting, restriction in purchase of required land, and maintenance of linear continuity. In particular, when the pillar width of tunnel decreases, the safety of pillars affects behaviors of the tunnel and therefore the need for diverse relevant studies has emerged. However, research so far has been largely confined to analysis of behavior characteristics of pillars, or parameters affecting design, and actually applicable and quantitative data have not been presented. Accordingly, in order to present a stability evaluation method which may maximally reflect construction conditions of spots, this study reflected topographical and stratigraphic characteristics of the portal part with the highest closeness between the tunnels, simulated multi-layer conditions with rock mass and complete weathering, and assessed the degree of effect the stability of pillars had on the entire tunnels through numerical analysis according to changes in pillar width by ground strength. This study also presented composite analysis result on ground surface settlement rates, interference volume rates, and average strength to stress and a formula, which may be applicable to actual work, to evaluate safety rates of closely spaced parallel tunnel pillars and minimum pillar width by ground strength based on failure criteria by Hoek-Brown (1980).

Analysis of Rainfall Runoff Delay Effect of Vegetation Unit-type LID System through Rainfall Simulator-based Probable Rainfall Recreation (인공강우기 기반 확률강우재현을 통한 식생유니트형 LID시스템의 우수유출지연 효과분석)

  • Kim, Tae-Han;Park, Jeong-Hyun;Choi, Boo-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.115-124
    • /
    • 2019
  • In a climate change environment where heat damage and drought occur during a rainy season such as in 2018, a vegetation-based LID system that enables disaster prevention as well as environment improvement is suggested in lieu of an installation-type LID system that is limited to the prevention of floods. However, the quantification of its performance as against construction cost is limited. This study aims to present an experiment environment and evaluation method on quantitative performance, which is required in order to disseminate the vegetation-based LID system. To this end, a 3rd quartile huff time distribution mass curve was generated for 20-year frequency, 60-minute probable rainfall of 68mm/hr in Cheonan, and effluent was analyzed by recreating artificial rainfall. In order to assess the reliability of the rainfall event simulator, 10 repeat tests were conducted at one-minute intervals for 20 minutes with minimum rainfall intensity of 22.29mm/hr and the maximum rainfall intensity of 140.69mm/hr from the calculated probable rainfall. Effective rainfall as against influent flow was 21.83mm/hr (sd=0.17~1.36, n=20) on average at the minimum rainfall intensity and 142.27mm/hr (sd=1.02~3.25, n=20) on average at the maximum rainfall intensity. In artificial rainfall recreation experiments repeated for three times, the most frequent quartile was found to be the third quartile, which is around 40 minutes after beginning the experiment. The peak flow was observed 70 minutes after beginning the experiment in the experiment zone and after 50 minutes in the control zone. While the control zone recorded the maximum runoff intensity of 2.26mm/min(sd=0.25) 50 minutes after beginning the experiment, the experiment zone recorded the maximum runoff intensity of 0.77mm/min (sd=0.15) 70 minutes after beginning the experiment, which is 20 minutes later than the control zone. Also, the maximum runoff intensity of the experiment zone was 79.6% lower than that of the control zone, which confirmed that vegetation unit-type LID system had rainfall runoff reduction and delay effects. Based on the above findings, the reliability of a lab-level rainfall simulator for monitoring the vegetation-based LID system was reviewed, and maximum runoff intensity reduction and runoff time delay were confirmed. As a result, the study presented a performance evaluation method that can be applied to the pre-design of the vegetation-based LID system for rainfall events on a location before construction.

The Study of Sediment Volume Concentration in Liquefied-Layer of Debris Flow (토석류 유동층에서 토사체적 농도 특성에 관한 연구)

  • Kim, Sungduk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.12
    • /
    • pp.109-115
    • /
    • 2014
  • The purpose of this study is to estimate the sediment volume concentration of the liquified-solid mixture which is included fine sediment fractions, according to the variance of the channel slope and the water supply. The numerical model was performed by using the Finite Differential Element Method (FDM) based on the equation for the mass conservation, momentum conservation and the equation of coarse sediment an fine sediment. In comparison of varying the channel slope, the deeper the channel slope, the inflection point of the sediment concentration was occurred rapidly. In comparison of variance of the water supply, as the water supply increases fluctuation with high sediment concentration. In this situation, debris flow changes to the turbulent flow and the sediment becomes to be floated. In comparison varying the length paved saturated sediment, the longer the length, the high concentration of sediment occurred, for the safety of the slope it is needed to check the possibility of the erosion in the slope by debris flow. The results of this study will provide useful information in predicting of the disaster by the liquified-solid mixture and in prevention of the debris flow with various the slope in the mountain side.

Combustion Properties of Wood Treated by Combining Phosphorus-Nitrogen Compounds (인-질소 화합물 조합에 의해 처리된 목재의 연소성)

  • Jin, Eui;Chung, Yeong-Jin;Kim, Si-Kuk
    • Applied Chemistry for Engineering
    • /
    • v.27 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • This study was to investigate the characteristics of combustion toxic gases of pinus rigida specimens treated with chemical additives such as pyrophosphoric acid (PP)/ammonuium ion ($NH_4{^+}$), methylenepiperazinomethyl-bis-phosphonic acid (PIPEABP) and $PIPEABP/NH_4{^+}$. Each pinus rigida plates was painted in three times with 15 wt% of each chemical additives in the aqueous solution. After drying these specimens at room temperature, the production of combustion gases and smoke was examined by the cone calorimeter (ISO 5660-1). As a result, the peak mass loss rate time (PMLR time) treated with chemicals was delayed upto 10.5~47.4% compared to that of using untreated specimen. In addition, the peak production of carbon monoxide ($CO\;_{peak}$) of 32.1~71.4% and total smoke release rate (TSRR) of 15.6~43.6% for test pieces treated with the chemical additive were higher than that of using the virgin plate. In particular, for the specimens treated with the chemical additive, the rate of smoke release (RSR) 29.4~41.5% was obtained higher than that of untreated plate except the specimen treated with $PP/4NH_4{^+}$. It can thus be concluded that the treatment using the chemical additive could partially increase the combustion-retardation properties of the species when compared to those of the virgin plate.

A Study on the Improvement of Huff's Method for Applying in Korea : II. Improvement of Huff's Method (Huff 강우시간분포방법의 개선방안 연구 : II. Huff 방법의 개선방안)

  • Jang Su-Hyung;Yoon Jae-Young;Yoon Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.9 s.170
    • /
    • pp.779-786
    • /
    • 2006
  • In this study, we propose a new method that utilizes rainfall data in and out of a basin, which is greater than 25.4mm for point rainfall or 12.7mm for areal mean rainfall respectively. From our analysis, most frequent quartile for point and areal mean rainfall were found to be the same in general for various rainfall duration intervals. From an evaluation of design rainfall per each rainfall duration distributed in time by the MOCT(Ministry of Construction and Transportation) version of Huff's method and this study, peak rainfall intensity by this study was found to be greater than the one by MOCT, but there were no consistent increase or decrease of this difference with rainfall durations. Using the distributed design rainfall per each duration by MOCT and this study, corresponding flood inflow hydrographs were simulated and compared each other. Contrary to the case of peak rainfall intensity, difference in peak flow by both methods per each rainfall duration started to increase from about 12-hr duration. Especially, the difference in peak flow was significant when critical rainfall duration was considered, and this trend was similar for peak flows of other rainfall durations. Therefore, the method proposed in this study is thought to be the effective procedure for the construction of dimensionless cumulative rainfall curve that is representative of a basin while considering time distribution characteristics for different rainfall durations.

A Study on the Improvement of Huff's Method in Korea : I. Review of Applicability of Huff's method in Korea (Huff 강우시간분포방법의 개선방안 연구 : I. Huff방법의 국내유역 적용성 검토)

  • Jang Su-Hyung;Yoon Jae-Young;Yoon Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.9 s.170
    • /
    • pp.767-777
    • /
    • 2006
  • The goal of this study is to improve Huff's method which is the most popular method for rainfall time distribution in Korea. As the first step, we reevaluated the context of Huff's original research motivations, geography and rainfall pattern of study area, and compared that to Korean situations. In original Huff's results, no change in temporal distribution characteristics were found for different rainfall durations. This was found to be different from Korean situations. Furthermore, results from the MOCT(Ministry of Construction and Transportation) version of Huff's method is on a gage basis not on a watershed basis, thus making it difficult to select cumulative rainfall curves representative of a watershed. In addition, all rainfall data regardless of their magnitude were used in the MOCT version of Huff' method which is different from original Huff's which screened out data by using a threshold value of 25.4mm. For both point and areal mean rainfall, time distribution characteristics of rainfall for various durations were found to be different. This was statistically proven by K-S test at 5% significance level as some cumulative rainfall curves developed from the rainfall data of certain durations were found to be not significant with cumulative rainfall curves developed from the rainfall data of all durations. Therefore, in order to apply Huff's method to Korean situations, it is recommended that dimensionless cumulative curve must be developed for various rainfall duration intervals using rainfall data greater than a certain threshold value.

A Study of the Improvement Plan and Real Condition Estimation of Fire Protection Safety Management for Power Plants in Korea (국내발전소 소방안전관리 운영실태조사 및 개선방안에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.61-73
    • /
    • 2017
  • The Fukushima Nuclear Disaster in 2011 and California Power Failure in 2001 are examples of the importance of the power plant safety management that caused huge national loss with a power-related mass casualty incident. In a situation where humans cannot live without electricity, efforts to strengthen the systematic firefighting safety management in power plants that produce electricity with large amounts of hazardous materials as fuel, such as nuclear energy, coal and gas, are essential to protect life and prevent property loss and stable economic growth from fire explosion accident or radiation leak due to the negligence of safety management and natural disasters such as earthquakes, which has recently become an issue. This study examined the operating situation of firefighting safety management in power plants with firefighting officials employed by five power generation companies including Korea Southern Power Co., Ltd. and Korea Hydro & Nuclear Power Co. Ltd., which are in charge of the domestic power supply. As a result, for the systematic firefighting safety management of power plants, improvement plans were drawn, including the development of an effective business manual and a comprehensive management system, the substantiality of firefighting safety education, and the strengthening of seismic designs to prepare for earthquakes.

Longitudinal Change in Health Status after the Sewol Ferry Accident among Bereaved Parents (세월호 참사 후 희생자 부모의 건강상태 변화)

  • Yang, Sang Eun;Tae, Hye Jin;Hwang, Jihyun;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.14 no.1
    • /
    • pp.44-52
    • /
    • 2018
  • Objective : The present study had examined the psychiatric symptoms and physical health consequences for the bereaved parents of the high school students who died in the 2014 Sewol ferry accident. Methods : Forty bereaved parents participated in the study. The authors administered self-report questionnaires about the parents' health behaviors and psychiatric symptoms. The authors also conducted laboratory tests to assess the parents' physical health at 18 and 30 months after the accident. Univariate descriptive statistics were performed to report the prevalence and severity of psychiatric symptoms and health-related behaviors. Paired t-test and Mcnemar test were performed to compare the 18-and 30-month findings. Correlation analysis between psychiatric symptoms and laboratory findings were performed to find a relationship between the two variables. Results : At 30 months after the accident, most of the bereaved parents still appeared to suffer from complicated grief (97.5%), post traumatic stress disorder (80%), insomnia (77.5%) and severe depression (62.5%) based on the scores on the Inventory of Complicated Grief (ICG), the PTSD Check List-5 (PCL-5), the Insomnia Severity Index (ISI) and the Patient Health Questionnaire-9 (PHQ-9). One quarter of the bereaved parents reported high-risk drinking, and 47.5% reported increased drinking amount and frequency after the accident. In objective laboratory results, 55% of the bereaved parents were obese as defined by body mass index ${\geq}25$. The parents' mean low-density lipoprotein shows a significant increase over time (118.5 mg/dL at 18 months. vs. 132.5 mg/dL at 30 months. paired t-test t=-4.061, $$p{\leq_-}0.001$$). Total cholesterol and low-density lipoprotein at 30 months after the accident were in clinically borderline high range. In correlation analysis, triglyceride was positively correlated with ISI. Conclusion : The loss of children in the Sewol ferry accident, a disaster caused by human error, continued to have considerable impact on the victims' parents' mental and physical health 18 and 30 months after the accident. A longitudinal study following the parents' physical health would be necessary to investigate the long-term effects of this traumatic experience on physical health.

Combustion Chracteristics of Wood Treated with Bis-(dialkylaminoalkyl) Phosphinic Acids (비스-디알킬아미노알킬 포스핀산으로 처리된 목재의 연소특성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.21-26
    • /
    • 2013
  • This study was performed to test the combustive properties of Pinus rigida plates treated with bis-(dimethylaminomethyl) phosphinic acid (DMDAP), bis-(diethylaminomethyl) phosphinic acid (DEDAP), and bis-(dibuthylaminomethyl) phosphinic acid (DBDAP). Pinus rigida specimens were painted in three times with 15 wt% bis-(dialkylaminoalkyl) phosphinic acid solutions at the room temperature. After drying specimen treated with chemicals, combustive properties were examined by the cone calorimeter (ISO 5660-1). It is supposed that the combustion-retardation properties were improved by the partial due to the treated bis-(dialkylaminoalkyl) phosphinic acids in the virgin Pinus rigida. Especially, the specimens treated with chemicals showed both the lower total smoke release rate (TSRR) ($16.94{\sim}18.92m^2/m^2$) and lower $CO_{2mean}$ production (1.98~2.09 kg/kg) than those of virgin plate. However the specimens treated with chemicals showed both the higher peak mass loss rate (PMLR) (0.1250~0.1297 g/s) and higher 1st-smoke production rate (SPR) (0.0153~0.0167 g/s) than those of virgin plate. Compared with virgin Pinus rigida plate, the specimens treated with the bis-dialkylamimoalkyl phosphinic acids showed partially low combustive properties.