• Title/Summary/Keyword: Masking

Search Result 747, Processing Time 0.03 seconds

The Noise Characteristics and Appropriate Talk Distance in Dental Clinic (치과병원의 소음특성과 적절한 대화거리)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2516-2523
    • /
    • 2013
  • Noise occurred when medical treatment in dental clinic will affect the patients. This study was measured the noise level and frequency in case of medical examination and also has evaluated the degree of indoor noise using the NR-curve, NRN and a distance to conversation between worker and patients using the PSIL. It shows that noise level was 69.3~81.5dB(A) and frequency was very high (more than 4K(Hz)) and analysis by NR-curve showed that it was exceed the noise permit level and distance to conversation was less than 1meter by PSIL. To remedy a fear of noise in patients and provide a conversational satisfaction, it's considered that choosing the low noise-vib. equipment, using the masking effect and set the room to explain. So It is possible to improve their competitiveness.

Comparative Proteomic Analysis of Human Amniotic Fluid Supernatants with Down Syndrome Using Mass Spectrometry

  • Park, Ji-Sook;Cha, Dong-Hyun;Jung, Jin-Woo;Kim, Young-Hwan;Lee, Sook-Hwan;Kim, Young-Jun;Kim, Kwang-Pyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.6
    • /
    • pp.959-967
    • /
    • 2010
  • Down syndrome (DS) is an abnormality of the 21st chromosome that commonly occurs in children born to older women. Thus, amniotic fluid (AF) is usually collected from such women for prenatal diagnosis. This study analyzed human AF supernatants (AFS) using a mass spectrometric (MS) approach to search for candidate biomarkers of a DS pregnancy. The AFS were collected from older pregnant women at weeks 16-18 of their gestation by amniocentesis for cytogenetic analysis. The AFS from the pregnancies carrying DS (n=4) or chromosomally normal (n=6) fetuses, as revealed by the cytogenetic analysis, were then subjected to global protein profiling based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Affinity chromatography was also applied prior to the LC-ESI-MS/MS to minimize the masking effect of highly abundant albumin and immunoglobulin and thereby increase the diversity of the identified proteins. As a result, at least 30 new AFS proteins were identified and 44 AFS proteins were found to be differentially expressed between the DS and normal cases, where 6 of the proteins were unique to the DS cases and 11 were unique to the chromosomally normal cases. In addition, in the DS cases, 19 AFS proteins were downregulated and 8 were upregulated to varying degrees. A Western blot analysis confirmed the LC-ESI-MS/MS data, indicating that the combined detection of apolipoprotein A-II (apoA-II) and alpha-fetoprotein (AFP) could be a potential tool for diagnosing DS cases.

Characteristics of Noise Radiated at Dental Clinic (치과병원에서 치료시 발생하는 소음특성)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1123-1128
    • /
    • 2009
  • Noise radiated from medical treatment at dental clinic will affect the patients. On such point of view, We investigated the noise characteristics in case of medical treatment (scaling, tooth eliminating) and non-medical examination (idling) and also evaluated the degree of indoor noise using the evaluation index such as PSIL, NRN and made up a questionnaire about the reactions to noise. As a result of noise evaluation, it shows that the range of noise level is 67.7~78.3 dB(A) and frequency is very high (above 4 k Hz) and respondents are affected by noise (unpleasantness, hesitation to visit dental clinic, shivering with noise, being astonishment). Analysis by PSIL showed that it was no problem to conversation between worker and patient. But it exceeded the noise permit level in working space by NR-curve. To relieve a fear of noise in patients, they are considered to offer the ear protection, choose the low noisevibration equipment and use the masking effect. They are of great advantage to dental clinics to i prove dental service and competitiveness.

Extraction of Computer Image Analysis Information by Desk Top Computer from Beef Carcass Cross Sections

  • Karnuah, A.B.;Moriya, K.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1171-1176
    • /
    • 1999
  • The precision and reliability of the Computer Image Analysis technique using a desk top computer for extracting information from carcass cross section scans was evaluated by the repeatability (R) and coefficient of variation (CV) for error variance. The 6th and 7th ribs cross section of carcasses from 55 fattened Japanese Black steers were used. The image analysis was conducted using a desk top computer (Macintosh-Apple Vision 1710 Display) connected to a scanner and an image capture camera. Two software applications, Adobe Photoshop and Mac Scope were used interchangeably. The information extracted and measured were individual muscle area, circumference length, long and short axes lengths, muscle direction; distance between any two muscle centers of gravity; cross section total area, lean, fat, and bone. The information was extracted after the processes of scanning, digitization, masking, muscle separation, and binarization. When using the Computer Image Analysis technique by desk top computer, proper digitization and selection of scanning resolution are very important in order to obtain accurate information. The R-values for muscle area, circumference, long and axes lengths, and direction ranged from 0.95 to 0.99, whereas those of the distance between any two muscle centers of gravity ranged from 0.96 to 0.99, respectively. For the cross section total area, lean, fat, and bone it ranged from 0.83 to 0.99. Excellent repeatability measurements were observed for muscle direction and distance between any two muscle centers of gravity. The results indicate that the Computer Image Analysis technique using a desk top computer for extracting information from carcass cross section is reliable and has high precision.

Experiences of Family Caregivers of Cancer Patients Receiving Chemotherapy

  • Sercekus, Pinar;Besen, Dilek Buyukkaya;Gunusen, Neslihan Partlak;Edeer, Aylin Durmaz
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.5063-5069
    • /
    • 2014
  • Background: Cancer is a disease which affects not only patients but also their families physically and emotionally. The purpose of this study was to determine the needs, challenges and ways of coping of caregivers of cancer patients. Materials and Methods: In the study, a phenomenological approach was used. Data were collected through semi-structured individual interviews. The study sample comprised 16 family members providing care for a cancer patient. Results: The study findings are grouped under four main themes: the impact of caregiving, masking feelings, experienced challenges and expectations, and coping. During the caregiving process, patient relatives are affected physiologically, psychologically and socially. It was determined that patient relatives hid their feelings and avoided talking about the disease for fear that they might upset the patient, and that they had difficulty in coping with the patient's reactions during the treatment process. Family members had difficulties arising from the health system, hospital conditions and treatment in addition to transportation and financial problems. Support is very important in coping, but it was determined that some of the relatives of patients did not receive adequate support. Patient relatives expect that health care professionals should provide them with more information about their patient's condition and the course of the disease that their patients should be dealt with by the physicians specialized in cancer, and that psychological support should be provided both for them and for their patient. Conclusions: During the caregiving process, family members are faced with many difficulties and they exhibit different coping behaviors which health care professionals should take into account.

A study on development of screen inspection system to detect damages, bowing, and foreign materials of nuclear fuel assembly for reactor in nuclear power plants (원전 연료집합체의 손상, 변형 및 이물질 검사시스템 개발에 관한 연구)

  • Park, Ki-Tae;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3617-3624
    • /
    • 2013
  • Screen inspection system applied vision and laser scan technology which detect foreign materials caused fuel rod to be damaged, and which inspect fuel rod damage, bowing, distortion and grid damages, was developed to secure reliability and reproductivity of inspection method for nuclear fuel assembly during outage. In further, datum of inspection results will be continuously monitored and given understand the pattern of bowing and distorting for fuel assembly in reactor. Understanding of the pattern will be key technical information to avoid grid demage might be happened during refueling outage and provides important data base for safe operation of nuclear power plant in Korea and world wide.

Video Watermarking Using Human Visual System and Wavelet Transform (인간 시각 시스템 및 웨이블릿 변환을 이용한 비디오 워터마킹)

  • 권성근;김병주;김태수;이석환;권기룡;이건일
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.3
    • /
    • pp.436-443
    • /
    • 2003
  • A digital video watermarking algorithm is proposed that uses HVS and DWT. In this algorithm, each video frame is decomposed into four-level by DWT which reveals the characteristics of the human eyes and watermark is embedded into DWT coefficients using HVS. For robustness, the lowest level subbands which represent the highest frequency component are excluded in watermark embedding step and watermark is embedded into the perceptually significant coefficients (PSCs) of the rest subbands. PSCs of the baseband are selected according to the amplitude of the coefficients and PSCs of the high frequency subbands are selected by successive subband quantization (SSQ). Watermark is embedded into the PSCs of the baseband and high frequency subbands by Weber's law and spatial masking effect, respectively, for the invisibility and robustness. We tested the performance of the proposed algorithm compared with the conventional watermarking algorithm by computer simulation. Experimental results show that the proposed watermarking algorithm produces a better invisibility and robustness than the conventional algorithm.

  • PDF

A Study on Image Coding using the Human Visual System and DCT (시각특성과 DCT를 이용한 영상부호화에 관한 연구)

  • 남승진;최성남;전중남;박규태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.4
    • /
    • pp.323-335
    • /
    • 1992
  • In this paper, an adaptive cosine transform coding scheme which incorporate human visual properties into the coding scheme is investigated. Human vision is relatively sensitive to mid-frequency band, and insensitive to very low and very high frequency band. These property was mathematically modelled with MTF(Modulation Transfer Function) through many psychovisual experiment. DCT transforms energy in spatial domain into frequency domain, so can exploit the MTF very efficiently. Another well-known visual characteristics is spatial masking effect that visibility of noise is less in regions of high activity than in regions of low activity. Proposed coding scheme imploys quantization matrix which represent the properties of these spatial frequency response of human vision, and adaptively quality of an image. To compute the activity index of an image block, simple operation is performed in spatial domain, and according to activity index. block of low activity region is more exactly quantized relatively than that of high activity region. Results showed that, at low bit rate, the subjective quality of the reconstructed images by proposed coding scheme is acceptible than that of coding scheme without HVS properties.

  • PDF

Preparation of Transparent and Conducting $SnO_2$ Thin Films by RF Magnetron Sputtering Method (RF 마그네트론 스퍼터링법에 의한 투명 전도성 $SnO_2$박막의 제조)

  • 신성호;박광자;김현후
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.2
    • /
    • pp.139-146
    • /
    • 1996
  • Transparent and conducting Sb-doped $SnO_2$ thin films were prepared by rf magnetron sputtering technology. But it showed a serious damage phenomenon on the surface of as-deposited films. In order to avoid a damage caused in the substrate center and location facing to target erosion, a ring plate of masking glass was installed at 1.5 cm above target surface. The uniformity and electrical characteristic of $SnO_2$ thin films were evaluated by the control of optimal conditions in the magnetron sputtering operation such as rf power, sputtering gas pressure, and substrate temperature. In the experimental results using the operating conditions, the optimum temperature, which produced uniform and damageless films, shifted with the change of gas pressure. The rate was about $100^{\circ}C$/5 mTorr at rf power of 50 W Similarly, the optimum temperature in compensation for an increase of rf power shifted down to a proper rate.

  • PDF

Fabrication and Characteristics of Lateral Type Field Emitter Arrays

  • Lee, Jae-Hoon;Kwon, Ki-Rock;Lee, Myoung-Bok;Hahm, Sung-Ho;Park, Kyu-Man;Lee, Jung-Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.2
    • /
    • pp.93-101
    • /
    • 2002
  • We have proposed and fabricated two lateral type field emission diodes, poly-Si emitter by utilizing the local oxidation of silicon (LOCOS) and GaN emitter using metal organic chemical vapor deposition (MOCVD) process. The fabricated poly-Si diode exhibited excellent electrical characteristics such as a very low turn-on voltage of 2 V and a high emission current of $300{\;}\bu\textrm{A}/tip$ at the anode-to-cathode voltage of 25 V. These superior field emission characteristics was speculated as a result of strong surface modification inducing a quasi-negative electron affinity and the increase of emitting sites due to local sharp protrusions by an appropriate activation treatment. In respect, two kinds of procedures were proposed for the fabrication of the lateral type GaN emitter: a selective etching method with electron cyclotron resonance-reactive ion etching (ECR-RIE) or a simple selective growth by utilizing $Si_3N_4$ film as a masking layer. The fabricated device using the ECR-RIE exhibited electrical characteristics such as a turn-on voltage of 35 V for $7\bu\textrm{m}$ gap and an emission current of~580 nA/l0tips at anode-to-cathode voltage of 100 V. These new field emission characteristics of GaN tips are believed to be due to a low electron affinity as well as the shorter inter-electrode distance. Compared to lateral type GaN field emission diode using ECR-RIE, re-grown GaN emitters shows sharper shape tips and shorter inter-electrode distance.