• 제목/요약/키워드: Mask sealing

검색결과 4건 처리시간 0.021초

백-밸브-마스크 환기 시 마스크 밀착방법에 따른 환기효과 비교 (Comparison of ventilation effects by mask-sealing methods during bag-valve-mask ventilation)

  • 이남종;백미례
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to compare the tidal volumes and airway pressures of 3 mask-sealing methods (one hand C-E, two hands C-E, and one hand O-E) for ventilation treatment. Methods: The study subjects were 45 paramedic students. Tidal volume was measured for the three sealing methods by setting a ventilator, connecting it to the masks for 2 minutes, and using Respi-trainer software. Results: Regarding general characteristics, the group of men, in upper grades, and with practical training experience and experience and experience in the implementation of bag-valve-mask ventilation provided higher tidal volumes. Regarding physical characteristics, larger hands and greater grip strength correlated with higher tidal volume. Two hands C-E generated the highest tidal volume of $483.78{\pm}34.14mL$, one hand O-E generated $449.59{\pm}51.09mL$ and one hand C-E generated $394.31{\pm}68.95mL$. Conclusion: Means of tidal volumes were statistically significantly different based on mask sealing methods (p<.001). Two hand C-E was performed by the two-persons task and was suggested as the most effective method. For the one-person task, one hand O-E was the more effective method compared to the previous one hand C-E.

구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교 (Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion)

  • 천경하;문준동
    • 한국응급구조학회지
    • /
    • 제21권3호
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

백-밸브-마스크 보조장치를 이용한 환기효과 비교 (A comparison of ventilation effects using bag-valve-mask assist device)

  • 서은영;윤병길;김가은;김용석
    • 한국응급구조학회지
    • /
    • 제26권3호
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: TThe experiment was designed to compare the efficiency of ventilation between conventional BVM ventilation and a newly devised A-BVM ventilation method with Tidal volume, total ventilation rate, average Ventilation speed, and average Ventilation volume. Methods: 40 Paramedical students who agreed to participate in the study were analyzed. Values were measured using IMB PASS after 2 minutes of Brayden Pro manikin with BVM and A-BVM ventilation. The difference in general characteristics was assessed by t-test and ANOVA and the difference in ventilation methods was analyzed by IBM SPSS. Results: A significant difference was found between the two ventilation methods in terms of tidal volume (t=-11.203, p<.001), ventilation time (t=-3.834, p<.001), and optimum ventilation probability (t=10.770, p<.001). A-BVM ventilation method, rather than BVM ventilation method, showed a value close to the appropriate amount recommended by Korean Advanced Life Support (500~600mL) in tidal volume, and higher in optimum ventilation probability. Conclusion: We could identify the a better mode of ventilation. Further studies on the efficacy of existing BVM ventilation methods as compared to device augmented BVM ventilation methods should be carried out to ensure that adequate ventilation is available to patients in clinical practice.

In Search of a Performing Seal: Rethinking the Design of Tight-Fitting Respiratory Protective Equipment Facepieces for Users With Facial Hair

  • Meadwell, James;Paxman-Clarke, Lee;Terris, David;Ford, Peter
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.275-304
    • /
    • 2019
  • Background: Air-purifying, tight-fitting facepieces are examples of respiratory protective equipment and are worn to protect workers from potentially harmful particulate and vapors. Research shows that the presence of facial hair on users' face significantly reduces the efficacy of these devices. This article sets out to establish if an acceptable seal could be achieved between facial hair and the facepiece. The team also created and investigated a low-cost "pressure testing" method for assessing the efficacy of a seal to be used during the early design process for a facepiece designed to overcome the facial hair issue. Methods: Nine new designs for face mask seals were prototyped as flat samples. A researcher developed a test rig, and a test protocol was used to evaluate the efficacy of the new seal designs against facial hair. Six of the seal designs were also tested using a version of the conventional fit test. The results were compared with those of the researcher-developed test to look for a correlation between the two test methods. Results: None of the seals performed any better against facial hair than a typical, commercially available facepiece. The pressure testing method devised by the researchers performed well but was not as robust as the fit factor testing. Conclusion: The results show that sealing against facial hair is extremely problematic unless an excessive force is applied to the facepiece's seal area pushing it against the face. The means of pressure testing devised by the researchers could be seen as a low-cost technique to be used at the early stages of a the design process, before fit testing is viable.