• Title/Summary/Keyword: Marginal Man

Search Result 71, Processing Time 0.034 seconds

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Indolent B-Cell Lymphoid Malignancy in the Spleen of a Man Who Handled Benzene: Splenic Marginal Zone Lymphoma

  • Lee, Jihye;Kang, Young Joong;Ahn, Jungho;Song, Seng-Ho
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.315-317
    • /
    • 2017
  • We present the case of a 45-year-old man with a history of benzene exposure who developed splenic marginal zone lymphoma. For 6 years, he had worked in an enclosed space cleaning instruments with benzene. He was diagnosed with splenic marginal zone lymphoma 19 years after retirement. During his time of working in the laboratory in the 1980s, working environments were not monitored for hazardous materials. We indirectly estimated the cumulative level of past benzene exposure using job-exposure matrices and technical assumptions. Care must be taken in investigating the relevance of occupational benzene exposure in the occurrence of indolent B-cell lymphoma. Because of the long latency period and because occupational measurement data do not exist for the period during the patient's exposure, the epidemiological impact of benzene exposure may be underestimated.

Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses

  • Yang, Min-Seong;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.250-261
    • /
    • 2022
  • PURPOSE. The purpose of this study was to analyze the marginal fit of three-unit resin prostheses printed with the stereolithography (SLA) method in two build orientations (45°, 60°) and two layer thicknesses (50 ㎛, 100 ㎛). MATERIALS AND METHODS. A master model for a three-unit resin prosthesis was designed with two implant abutments. Forty specimens were printed using an SLA 3D printer. The specimens were printed with two build orientations (45°, 60°), and each orientation was printed with two layer thicknesses (50 ㎛, 100 ㎛). The marginal fit was measured as the marginal gap (MG) and absolute marginal discrepancy (AMD), and MG and AMD measurements were performed at 8 points per abutment, for 16 points per specimen. All statistical analyses were performed using SPSS software. Two-way analysis of variance (ANOVA) was separately performed on the MG and AMD values of the build orientations and layer thicknesses. Moreover, one-way ANOVA was performed for each point within each group. RESULTS. The margins of the area adjacent to the pontic showed significantly high values, and the values were smaller when the build orientation was 45° than when it was 60°. However, the margin did not differ significantly according to the layer thicknesses. CONCLUSION. The marginal fit of the three-unit resin prosthesis fabricated by the SLA 3D method was affected by the pontic. Moreover, the marginal fit was affected by the build orientation. The 45° build orientation is recommended.

Efficiency and Robustness of Fully Adaptive Simulated Maximum Likelihood Method

  • Oh, Man-Suk;Kim, Dai-Gyoung
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.3
    • /
    • pp.479-485
    • /
    • 2009
  • When a part of data is unobserved the marginal likelihood of parameters given the observed data often involves analytically intractable high dimensional integral and hence it is hard to find the maximum likelihood estimate of the parameters. Simulated maximum likelihood(SML) method which estimates the marginal likelihood via Monte Carlo importance sampling and optimize the estimated marginal likelihood has been used in many applications. A key issue in SML is to find a good proposal density from which Monte Carlo samples are generated. The optimal proposal density is the conditional density of the unobserved data given the parameters and the observed data, and attempts have been given to find a good approximation to the optimal proposal density. Algorithms which adaptively improve the proposal density have been widely used due to its simplicity and efficiency. In this paper, we describe a fully adaptive algorithm which has been used by some practitioners but has not been well recognized in statistical literature, and evaluate its estimation performance and robustness via a simulation study. The simulation study shows a great improvement in the order of magnitudes in the mean squared error, compared to non-adaptive or partially adaptive SML methods. Also, it is shown that the fully adaptive SML is robust in a sense that it is insensitive to the starting points in the optimization routine.

A Case of Primary Pulmonary Extranodal Marginal Zone B-Cell Lymphoma of the MALT Type (폐에 발생한 림프절외 변연부 B-세포 림프종 1예)

  • Han, Minsoo;Kang, Dong Wook;Choi, Gi Young;Lee, Yang Deok;Cho, Yong Seon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.6
    • /
    • pp.635-639
    • /
    • 2003
  • An extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) is the most frequent type of non-Hodgkin's lymphoma that primarily involves the lung. The radiographical discovery of a pulmonary lesion in an asymptomatic patient is the most common clinical presentation. In general, the prognosis of a localized extranodal pulmonary marginal zone B-cell lymphoma of MALT type is excellent. We report a case of a 61-year-old man who sought evaluation of an incidentally discovered mass in the lung.

Pigouvian Tax and the Congestion Externality -A Benefit Side Approach- (도로혼잡 외부효과와 피구세: 편익측면 분석)

  • Lee, Dug Man
    • Environmental and Resource Economics Review
    • /
    • v.12 no.1
    • /
    • pp.75-90
    • /
    • 2003
  • In this paper we have shown that a Pigouvian tax is an adequate resolution of congestion externality to attain Pareto optimality using utility maximization. For this objective, taking an open access freeway as an example, we not only derived both marginal private benefit and marginal social benefit, but also assessed the divergence between marginal private benefit and marginal social benefit. As a result, we identified that the amount of a Pigouvian tax should be the same amount as the external time cost, which is the value of the marginal time cost to Individual a incurred by Individual b through freeway congestion. This Pigouvian tax coincides with the profit or wealth maximizing toll suggested by literature on the basis of profit maximization. In addition, because an open access freeway is accounted as common property resource, we proved that average social congestion cost is essentially equal to marginal private congestion cost in our model. Finally, we showed that the optimal value of trip derived in our model is the same as that generated on profit maximization approach.

  • PDF

Complications of implants confronting the extruded posterior teeth (정출된 구치와 대합되는 임플란트의 합병증)

  • Jung, Yeon-Wook;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.232-241
    • /
    • 2020
  • Purpose: This study investigated the complications and patterns of implants that confronted with the extruded natural teeth. Materials and Methods: Among patients who received implant treatment between 2006 and 2018 at Chosun University Dental Hospital, only implants that had a maintenance period of at least 5 years and that both implants and confronting natural teeth could be measured and compared on a radiograph were selected. They were divided into two groups. Group 1, experimental group consisted of Implants confronting the extruded natural posterior teeth (n = 167: maxilla (Group 1max) = 92, mandible (Group 1man) = 75) and Group 2, control group consisted of Implants confronting the normal natural posterior teeth (n = 656: maxilla (Group 2max) = 272, mandible (Group 2man) = 384). Results: The incidence of complications between Group 1 and Group 2 was statistically significant. In particular, there was a statistically significant difference between the frequency of marginal bone loss and the amount of marginal bone loss. Conclusion: The extruded natural tooth may cause more frequent complications including bone resorption in the opposing implant.

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

A Study on the Monitoring of Market Power using Contingent Transmission Rights in Competitive Electricity Markets (경쟁적 전력시장에서 Contingent Transmission Rights을 이용한 지역적 시장지배력 감시방안)

  • Park, Jung-Sung;Han, Seok-Man;Kim, Bal-Ho
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.256-276
    • /
    • 2006
  • Transmission congestion is one of the key factors to local market power in competitive electricity markets. Financial transmission rights provide the financia] protection to their holders by paying back the congestion rent. A variety researches have shown that the existing trading mechanisms on transmission right can exacerbate market power. This paper proposes an alternative methodology in mitigating the local market power using the Contingent Transmission Rights on the locational marginal pricing scheme. The proposed methodology was demonstrated with the Optimal Power Flow.