• Title/Summary/Keyword: Manufacturing Variation

Search Result 734, Processing Time 0.021 seconds

A Comparative Study on the Change in Oriental Linked pearls Pattern (동전(東傳) 연주문의 변천과정 비교연구 -5세기~10세기 벽화복식 및 출토 직물을 중심으로-)

  • An, Bo-yeon
    • Korean Journal of Heritage: History & Science
    • /
    • v.40
    • /
    • pp.243-270
    • /
    • 2007
  • Linked pearls pattern expressed on textiles have no limited scale or shape when manufacturing, so they are free in expression. And from the design, material, and color we can analogize the social culture of that age. Oriental linked pearls pattern was started from the Sasanian Persia and introduced through the Silk Road, so it is closely connected with the East and the West culture. This study will consider from the 5th century to the 10th century; the mural costume of the West Central Asia, the ancient textiles excavated from the Sinjiang and Qinghai area of China, and the linked pearls pattern which are collected at Shosoin, Japan. And from this study, will concentrate on clarifying the linked pearls pattern's condition of the cultural exchange between the East and the West and it's structural variation process. The design of linked pearls pattern delivered to the East through the Silk Road is differed by area. For example, in the Western Pamir Plateau, where the ancient Sogdians mainly lived, the excavated linked pearls pattern's subject were deer or cassowary variated from the West Asian motif. But the ones excavated from Kucha Xingang had Chinese motifs added so they showed Chinese characters or Buddhist Bodhisattva image instead of Helios. Like this, the appearance of new patterns, which were accompanied by structural variations, gradually deviated from the standardized pattern of the Sasanian Persia. And this structural variation process has relations with the construction and arrangement method of various patterns of the after ages. The foliated floral Spray, which is placed at the lozenge space of linked pearls' space, had developed into ogival - shaped pattern (Neunghwamun). And the prevalence of geometrical structure pattern after the 10th century and the unfolding method of Tapjamun which is arranging unit pattern in order, are similar to the linked pearl pattern. In brief, linked pearls pattern accompanied by technical improvement let us understand the polished artistic code from its expression, and has importance in showing universal pattern beyond region and culture.

Mineralogical Composition and Physical Variation of Reproduced Potteries based on Chemical Composition and Firing Temperature (화학조성과 소성온도에 따른 재현 토기의 광물조성과 물성변화)

  • Kim, Su-Kyoung;Han, Min-Su;Moon, Eun-Jung;Kim, Young-Hee;Hwang, Jin-Ju;Lee, Han-Hyoung
    • Journal of Conservation Science
    • /
    • v.26 no.3
    • /
    • pp.311-324
    • /
    • 2010
  • The purpose of this study aims to reveal characteristics of reproduced potteries which made with clays of various chemical compositions in different firing temperatures and thereafter to provide comparative samples for identifying the manufacturing techniques of earthenwares from archaeological excavation by reproducing and characterizing sample under controlled conditions. For this study, various samples of earthenware are reproduced using different types of raw clays at several different firing temperature, followed by physical and structural characterization. Chemical specification were varied from different types of clay, which were calculated by Seger formula, and four different types of clay were selected based on different mole ratio of acidic oxide. The temperatures of firing of 7 samples were varied between $600^{\circ}C$ to $1200^{\circ}C$ at the interval of $100^{\circ}C$ for each sample. The result of analysis revealed that each reproduced earthenware has different chemical compositions divided into two groups: 1. Sample Y(6.10) and Sample G(5.85) clay; 2. Sample H(3.41) and Sample S(2.85) clay. The former which has higher mole ratio of acidic oxide than the latter, shows higher level of rockwell hardness at the same firing temperature. In addition, all four samples presented that as the firing temperature was increased, absorption rates of Y and G were abruptly dropped at $1200^{\circ}C$. Furthermore the more mole ratio of acidic oxide increase, the more microtexture of samples were vitrificated. Such result reveals that mole ratio of acidic oxide influence physical and microtextural characteristics of earthenwares, and it can be used as the comparison data in the understanding of manufacture techniques for the earthenwares of similar chemical composition.

Numerical Prediction for Fluidized Bed Chlorination Reaction of Ilmenite Ore (일메나이트광의 유동층 염화반응에 대한 수치적 예측)

  • Chung, Dong-Kyu;Jung, Eun-Jin;Lee, Mi Sun;Kim, Jinyoung;Song, Duk-Yong
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.107-113
    • /
    • 2019
  • Numerical model that considered the shrinking core model and elutriation and degradation of particles was developed to predict selective chlorination of ilmenite and carbo-chlorination of $TiO_2$ in a two stage fluidized bed chlorination furnace. It is possible to analyze the fluidized bed chlorination reaction to be able to reflect particle distribution for mass balances and the chlorination reaction. The numerical model showed an accuracy with error less than 6% compared with fluidized bed experiments. The chlorination degree with particle size change was greater with a smaller particle size, and there was a 100 min difference to obtain a chlorination degree of 1 between $75{\mu}m$ and $275{\mu}m$. This was not shown to such a great extent with variation of temperature ($800{\sim}1000^{\circ}C$), and there was only a 10 min difference to obtain a chlorination degree of 0.9. In the first selective chlorination process, the mass reduction rate approached to the theoretical value of 0.4735 after 180 min, and chlorination changed the Fe component into $FeCl_2$ or $FeCl_3$ and showed nearly 1. In the second carbo-chlorination process, the chlorination degree of $TiO_2$ approached 0.98 and the mass fraction reached 0.02 with conversion into $TiCl_4$. In the first selective chlorination process, 98% of $TiO_2$ was produced at 180 min, and this was changed into 99% of $TiCl_4$ after an additional 90 min. Also the mass reduction rate of $TiO_2$ was reduced to 99% in the second continuous carbo-chlorination process.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF