Correlation of XE-2100, ADVIA-120 and Manual Differential Count and Evaluation of Morphology Flag (자동혈구분석기 XE-2100, ADVIA-120와 Manual Differential Count의 상관성 및 Morphology Flag 평가)

  • Lee, Bum Hee;Byun, Nam Sub;Gee, Myung Suk;Song, Soon Young;You, Seon Woo;Park, Hyo Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • With technological advances in automatic hematology analyzers, primary and screening differential counts of white blood cells (WBC) are done with automatic hematology analyzers. They are using different measurement and analysis principles, so differences in WBC differentials and WBC morphology flag exist. This study was carried out to analyze WBC differential counts and WBC morphology flags comparing them with the manual method. Patient EDTA samples in Vacutainer requested for WBC differentials were analyzed with XE-2100. And those samples with suspect flags messages index over 100 were selected and were analyzed with ADVIA-120. Peripheral blood smear film was subsequently made. Three investigators counted 200 cells each (600 cells) in 111 Wright-Giemsa stained blood films. Between two automatic hematology analyzers, neutrophil, lymphocyte, eosinophil, and monocyte showed good correlations, but basophil had moderate correlation. Among automatic hematology analyzers and manual count, neutrophil, lymphocyte, and eosinophil had good correlations, but monocyte had moderate correlation. XE-2100 had higher monocyte, which was due to atypical lymphocyte and myeloblast. LUC in ADVIA-120 was not due to monocyte in XE-2100. Morphology flagging rates were 146.9% in XE-2100 and was 93.2% in ADVIA-120. Positive predictive values of morphology flag were 58.2% in XE-2100 and 54.4% in ADVIA-120. Flags such as atypical lymphocyte, immature granulocyte, and left shift had higher predictive values and those such as N-RBC, platelets clump, and blast had lower ones. Between automatic hematology analyzers, WBC differentials showed good correlations. Predictive values for morphology flags can be variable with changing criteria. Reviewing criteria for WBC differentials and morphology flags should be established in each laboratory with regards to size of laboratory and patients it serves.

  • PDF

Evaluation of Coulter® LH 750TM on Leukocyte Differential Count and Suspect Flags (Coulter® LH 750TM에 의한 백혈구 감별계산 및 Suspect Flags의 평가)

  • Hong, Seung-Bok;Choi, Jong-Tae;Lee, Seong-Kyu;Kim, Hyun-Soo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2005
  • Automatic hematology analyzers provide the leukocyte differential count and the useful flags of the various hematological parameters. We compared LH 750 (Beckman Coulter Co., Miami, FL, USA) with manual method on differential leukocyte counts and evaluated the usefulness of the suspect flags, provided by this instrument. The comparison of leukocyte differential counts between two methods showed good correlation coefficient (r), which were 0.95 (neutrophil), 0.92 (lymphocyte), 0.82 (monocyte) and 0.95 (eosinophil). The frequency of the total flags displayed on LH 750 were 15.5%, which included immature granulocyte/left shift 63.5%, nucleated RBC 14.6%, platelet clumps 13.1%, variant lymphocyte 50% and blast 16.6%. This instrument showed higher positive predictive value in the flags such as platelet clumps 68.8%, immature granulocyte/left shift 61.5%, nucleated RBC 27.3%, variant lymphocyte 50% and blast 16.7%. In this study, the leukocyte differential counts of LH 750 showed good correlation with manual method and the suspect flags also showed a good performance for applying the criteria of re-examination in the clinical laboratory.

  • PDF

A Comparison of Complete Blood Cell Count in Canine Blood Samples Obtained from the Jugular Vein, Cephalic Vein and Lateral Saphenous Vein

  • An, Hyung-Mo;Song, Joong-Hyun;An, Su-Jin;Yu, Do-Hyeon;Kim, Young Joo;Han, Donghyun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.314-318
    • /
    • 2019
  • The purpose of this study was to compare the results of complete blood cell count (CBC) of blood samples collected from the jugular vein, cephalic vein and lateral saphenous vein and to find out if there were clinically significant differences. Total of 40 dogs were tested. CBC tests were conducted with blood samples obtained from the jugular vein, cephalic vein and lateral saphenous vein and manual differential count was performed to accurately distinguish the white blood cell (WBC) types. The results were analyzed using Repeated Measures ANOVA and posthoc test was conducted using the least significant difference method. As a result, there was a statistically significant difference (P < 0.05) in the total WBC and monocyte count. The post-hoc test of total WBC counts revealed a significant difference between the jugular vein and cephalic vein, and the jugular vein and lateral saphenous vein. For monocyte counts, a significant difference was observed between the jugular vein and lateral saphenous vein.

Recent Development of Rapid and Automation Technology for Food Microbiological Examination

  • Hiroshi Kurata
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1996.06a
    • /
    • pp.33-33
    • /
    • 1996
  • Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.

Test turnaround Time for Complete Blood Cell Count using Delta and Panic Value Checks and the Q-flag Limit

  • Koo, Bon-Kyung;Ryu, Kwang-Hyun;Lim, Dae-Jin;Cho, Young-Kuk;Kim, Hee-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.66-74
    • /
    • 2012
  • Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) processed around 10% and 1 unit of ADVIA-2120 (Siemens AG, Munich, Germany) processed around 10%. We analyzed the change in the TAT for the CBC for over 7 years, from January of 2005 to December of 2011. The delta check made alterations of delta to WBC, hemoglobin, hematocrit, platelet and metamyelocyte, however, did not made them to band neutrophil, eosinophil, basophil and monocyte. The panic value check made alterations of panic value to hemoglobin, hematocrit, platelet and monocyte. In the criteria of currently slide review, LH-780 and ADVI-2120 analyzers prepared suspect flags of "Blast, Imm NE2, Immature granulocyte, Imm NE1, Left shift, Variant lymphocyte, Atypical lymphocyte, Platelet clumps and NRBC". The New slide review in the XE-2100 analyzer altered the preparations of a smear slide more than a "Platelet clumps flag(${\geq}200unit$), a single flag excluding the "Platelet clumps flag (${\geq}250unit$) and a multiple flag (${\geq}200unit$)". Also, below the 240 unit, medical technologists prepared manual slides selectively according to their evaluations. The automatic reporting rate was 33.4% without alterations, whereas it was 41.0% without alterations, and was thus improved by 7.6%. The slide review rate was 15.2% before using the Q-flag limit, whereas it was 12.1% for a reduce 3.1%. TAT was 45 minutes without the creation alterations of the delta and panic value checks, whereas it was 35 minutes after making alterations of the delta and panic value checks and thus was shortened by 10 minutes. We came to the conclusion that the establishment and operation of delta and panic value checks and slide review criteria suitable for laboratory environment can reduce unnecessary smear slides, re-checking, re-sampling, re-testing, telephone inquiries and concentrated workloads during specific times of the day.

  • PDF

Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer (분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험)

  • Sung, Hyun-Ho;Seok, Dong-In;Jung, You-Hyun;Kim, Dae-Jung;Lee, Seok-Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.382-389
    • /
    • 2017
  • Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700~780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.

Isolation and Identification of Staphylococcus sp. from Korean Fermented Fish Products

  • Um, Mi-Na;Lee, Cherl-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.5
    • /
    • pp.340-346
    • /
    • 1996
  • In order to find out if staphylococci occur in significant numbers in Korean fermented fish products, a total of 40 different fermented fish products were collected from different markets in Korea and analyzed for their physico-chemical and microbiological states. The pH, salt concentration and water activity of the products were measured and the total viable cell count and the number of Staphylococcus grown on mannitol salt agar were determined. The identification of the strains of Staphylococcus were made by API Staph Strip and MIS identification kits, and the physiological properties of the identified strains were further characterized by different conventional methods. The pH, salt content and water activity of fermented fish samples varied widely from 4.8 to 7.1, 7.4-28.7$%$ and 0.77-0.84, repectively, depending on the type of product. The total viable cell count varied from $10^4-10^9$ cfu/ml, and most of the samples had $10^5-10^6$ cfu/ml No correlation was found between the viable cell count and the pH, NaCl concentration and water activity of the samples. Among the 35 colonies identified as Staphylococcus strains by the identification kits, S. xylosus was the most frequently occurring strain marking 17, and S. warneri was 8, S. epidermidis 4 and S. cohnii 2. S. hominis, S. saprophyticus, S. haemolyticus and S. aureus were also identified once each. In some samples (K-3, P-6, K-8, G-5 and G-10), 2-3 different species of Staphylococcus were found. Considering the region of sampling, among the 10 samples from Kunsan 5 were identified as S. warneri, while in the other regions S. xylosus was predominant. Although the physiological characteristics of the identified strains were generally consistent with those in Bergey's Manual, some discrepances were also observed. All the strains were highly salt tolerant, growing in the media containing over 18$%$ NaCl. All the strains except S. aureus (G-11) showed negative in hemolysis activity, plasma coagulation and DNase tests. All the strains including S. aureus (G-11) showed negative in enterotoxin test.

  • PDF

An Automatic Mobile Cell Counting System for the Analysis of Biological Image (생물학적 영상 분석을 위한 자동 모바일 셀 계수 시스템)

  • Seo, Jaejoon;Chun, Junchul;Lee, Jin-Sung
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • This paper presents an automatic method to detect and count the cells from microorganism images based on mobile environments. Cell counting is an important process in the field of biological and pathological image analysis. In the past, cell counting is done manually, which is known as tedious and time consuming process. Moreover, the manual cell counting can lead inconsistent and imprecise results. Therefore, it is necessary to make an automatic method to detect and count cells from biological images to obtain accurate and consistent results. The proposed multi-step cell counting method automatically segments the cells from the image of cultivated microorganism and labels the cells by utilizing topological analysis of the segmented cells. To improve the accuracy of the cell counting, we adopt watershed algorithm in separating agglomerated cells from each other and morphological operation in enhancing the individual cell object from the image. The system is developed by considering the availability in mobile environments. Therefore, the cell images can be obtained by a mobile phone and the processed statistical data of microorganism can be delivered by mobile devices in ubiquitous smart space. From the experiments, by comparing the results between manual and the proposed automatic cell counting we can prove the efficiency of the developed system.

Transform Nested Loops into MultiThread in Java Programming Language for Parallel Processing (자바 프로그래밍에서 병렬처리를 위한 중첩 루프 구조의 다중스레드 변환)

  • Hwang, Deuk-Young;Choi, Young-Keun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.8
    • /
    • pp.1997-2012
    • /
    • 1998
  • It is necessary to find out the parallelism in tlle sequential Java program to execute it on the parallel machine. The loop is a fundamental source to exploit parallelism as it process a large portion of total execution time in sequential Java program on the parallel machine. However, a complete parallel execution can hardly be achieved due to data dependence. This paper proposes the method of exploiting the implicit parallelism by structuring a dependence graph through the analysis of data dependence in the existing Java programming language having a nested loop structure. The parallel code generation method through the restructuring compiler and also the translation method of Java source program into multithread statement. which is supported by the Java programming language itself, are proposed here. The perforance evaluatlun of the program translaed into the thread statement is conducted using the trip cunt of loop and the trip Count of luop and the thread count as parameters The resttucturing compiler provides efficient way of exploiting parallelism by reducing manual overhead conveliing sequential Java program into parallel code. The execution time for the Java program as a result can be reduced un the parallel machine.

  • PDF

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF