• Title/Summary/Keyword: Manikin

Search Result 147, Processing Time 0.027 seconds

A Study on Wearing Satisfaction and Thermal Properties of Jumper for Korean Military Tank Drivers (전차병 점퍼의 착용만족도 및 보온성에 관한 연구)

  • Kwon, Seo-Yoon;Choi, Eun-Mi;Lim, Chae-Guen;Shin, Dong-Woo;Kim, Kyung-Pil;Kwon, Oh-Kyung;Jeong, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.261-268
    • /
    • 2012
  • The purpose of this study is to investigate problems of design, fitness, suitability for movement, and wearing comfort of jumper for Korean military tank drivers through analysis of actual wearing condition by questionnaire and field evaluation and to provide basic data for developing its improved design. The survey was done for 477 military tank drivers and evaluation was performed using thermal manikin to measure insulation. The overall satisfaction for design of jumper for military tank driver was over 3.5(likert scale). The overall satisfaction for fitness of jumper for military tank driver was also over 3.5. The satisfactions for material was between 2.39 and 3.13 and the satisfaction for pilling property was the lowest, followed by static property and shape stability after laundering. The satisfactions for movement suitability were standing(3.81), sitting(3,38), raising hand(forward: 2.90, sideward: 3.01), respectively. In insulation evaluation of jumper for military tank drivers and outwears(jacket, jumper), the insulation of jumper for military tank drivers was lower than outwear(jumper) and same with outwear(jacket). The insulation in dynamic and still condition(without wind) of jumper for military tank driver was 0.37clo and 0.31clo, respectively. Its decreation rate in dynamic condition comparing to still condition was 59% which was lower than jacket(0.73clo) and jumper(1.15clo).

The Analysis of the Sweating Rate, Skin Temperature on the Upper Body and Subjective Sensations (상반신의 부분별 발한량, 피부온과 주관적 감각 고찰)

  • Kim, Seong-Suk;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.993-999
    • /
    • 2013
  • This study aimed to measure the amount of sweating on 12 parts of the upper body using absorption fabric and analyze subjective sensations. The study was conducted with 9 male subjects in climate chamber controled at $30{\pm}0.5^{\circ}C$, and $55{\pm}5%$ RH. The result was that sweating amount of the upper back part was significantly more than upper front part. We assumed that forced convection flow cased by exercise decreased the sweating rate in the front. The skin temperature of upper front body rapidly decreased as soon as exercise starts and gradually increased with cessation of exercise. On the other hand, the skin temperature of palm increased with exercise and showed continuous increasing even exercise stopping all the experimental period. This is caused by thermoregulatory responses through vasodilatation on the peripheral area. Subjective sensations, such as thermal sensation, wet sensation, and thermal comfort showed the highest score at the time of exercise stop. This means the subjects felt more hot, wet, and uncomfortable after exercise stopped. Bur after wiping of sweat, subjective sensation scores were recovered rapidly. The present study has provided more detailed information on the upper body sweat distribution than previously available, which can be used in clothing design, thermo-physiological modeling, and thermal manikin design. We also think that results of the present study will play an important role in making the sweat distribution map.

Use of PC Skillreporting system for Improving Quality of Cardiac Pulmonary Resuscitation in Fire EMT (구급대원의 심폐소생술 질 향상을 위한 PC Skillreporting system 활용방안)

  • Rho, Sang-Gyun;Moon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1498-1503
    • /
    • 2010
  • PC Skillreporting feedback during cardiopulmonary resuscitaion would improve the performance of chest compression and ventilation during cardiac arrest. BLS skills were measured using Laerdal Skillreporter manikin(Laerdal, Norway) connected to a Laerdal PC Skillreporting system. Ventilation volume, chest compression accuracy, velocity of compression, depth of compression, hand position and chest recoil were measured between the two groups. Ventilation volume was significantly higher in the experimental group than that of control group(p<0.002). Chest compression depth was significantly higher in experimental group than that of control group(p=0.000). The quality of CPR can be improved by the use of PC Skillreporting system.

Relationship between Non-technical Skills and Resuscitation Performance of Nurses' Team in in-situ Simulated Cardiac Arrest (심정지 현장 시뮬레이션에서 일반 간호사의 비기술적 술기와 심폐소생술 수행 간의 관계)

  • Kim, Eun Jung;Lee, Kyeong Ryong
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.2
    • /
    • pp.146-155
    • /
    • 2015
  • Purpose: The aim of this descriptive study was to explore the relationship between non-technical skills (NTSs) and cardiopulmonary resuscitation (CPR) performance of nurses' teams in simulated cardiac arrest in the hospital. Methods: The sample was 28 teams of nurses in one university hospital located in Seoul. A high fidelity simulator was used to enact simulated cardiac arrest. The nurse teams were scored by raters using both the CPR performance checklist and the NTSs checklist. Specifically the CPR performance checklist included critical actions; time elapsed to initiation of critical actions, and quality of cardiac compression. The NTSs checklist was comprised of leadership, communication, mutual performance monitoring, maintenance of guideline, and task management. Data were collected directly from manikin and video recordings. Results: There was a significant difference between the medians of the NTSs and CPR performance (Mann Whitney U=43.5, p=.014). In five subcategories, communication (p=.026), mutual performance monitoring (p=.005), and maintenance of guideline (p=.003) differed significantly with CPR performance in medians. Leadership (p=.053) and task management (p=.080) were not significantly different with CPR performance. Conclusion: The findings indicate that NTSs of teams in addition to technical skills of individual rescuers affect the outcome of CPR. NTSs development and assessment should be considered an integral part of resuscitation training.

Boundary Element Analysis for Head-Related Transfer Function in the Case of Korean Adults (경계요소법을 이용한 한국인 머리관련 전달함수의 특성 해석)

  • Lee, Doo-Ho;Ahn, Tae-Soo;Ki, Dong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1035-1044
    • /
    • 2010
  • Head-related transfer function (HRTF) is an acoustic transfer function from a sound source to the ear canal entrance position. HRTFs are very important information in the construction of virtual sound fields. HRTFs also vary for different individuals. In this study, characteristics of HRTF for an average Korean are investigated numerically by comparing with the HRTF for a standard Knowles Electronics Manikin for Acoustic Research (KEMAR). A boundary element (BE) model for an adult Korean is developed using the computerized tomography (CT) data in order to investigate the variation in HRTFs for different individuals. The boundary conditions of the BE model are identified by comparing the numerical results with the experimental results. The numerical model shows that accurate HRTFs can be calculated efficiently over full audible frequency range for individuals.

A Study on the Mechanical and Comfort Performances of the Working Uniform for a Volunteer Fire Brigade Member (의용소방대용 근무복 소재의 역학적 특성 및 쾌적성에 관한 연구)

  • Kwon, Myoung-Sook;Shim, Huen-Sup;Kwon, Jin
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.3 s.112
    • /
    • pp.53-62
    • /
    • 2007
  • The purpose of this study was to investigate mechanical and comfort performances of the material for the improved working uniform for a volunteer fire brigade member, to get basic data for its evaluation and to help its material and design development. The results were as follows; The material of the newly developed working uniform was thinner and lighter than the material of the current used working uniform. It had better breathability, air permeability and heat transmission rate than the current one. It also had superior anti-flammability In all mechanical properties(tensile, bending, shearing, compression and surface properties), it showed better performances than the current one. It elongated and bended easier and more in both warp and weft directions. The elastic recovery and shape stability after elongation were also higher. The recovery and resistance to shearing and the resiliency and recovery after compression were also better than the current one. It was more flexible, softer and smoother in primary hand value, and was more suitable for the material for winter suit which needs softness and fullness in total hand value. The material of the improved working uniform showed lower thermal insulation value and higher evaporative resistance value compared to the material of the currently used working uniform from the sweating thermal manikin test. It was shown that the physical performances and the hand value of the textile material used in the newly developed working uniform for a volunteer fiber brigade member was improved compared to the one used in the currently used working uniform.

Retention of cardiopulmonary resuscitation skills in Nursing students (간호대학생 대상 심폐소생술 교육의 지속효과)

  • Park, Jeong-Mi;Suh, Soon-Rim
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.169-180
    • /
    • 2005
  • The purpose of this research was to evaluate retention of cognitive knowledge, psychomotor skills and self-confidence on CPR 3 months after CPR training program. The sample consisted of 39 nursing students. We provided one rescuer CPR training program for nursing college students on the basis of AHA. The questionnaires for knowledge of CPR were developed 50 items based on AHA guidelines. Self-confidence were checked by 11 items questionnaires. The accuracy of CPR skills were checked by Skillreporter CPR training manikin and by researcher's evaluation based on CPR skill checklist. The results were as follows ; 1. The majority of participants didn't have any previously experiences of CPR training (76.9%). Only 15.1% previously took the CPR training with CPR practice. 2. In terms of self-confidence of CPR. The score were increased for 2 days (p>.001) but retention of self confidence was significantly statistical decreased in 3 months after training (p<.001). 3. There was a statistically significant decrement in mean of knowledge of CPR between 2 days and 3 months after CPR training (p<.001). 4. There was a statistically significant decrement in cognitive knowledge of CPR based on CPR skills checklist(p<.001). 5. Retention scores of psychomotor skills of CPR 3 months after training were 42.10% in numbers of adequate ventilation, 52.81% in numbers of adequate chest compression (p<.001) respectively. 6. Retention of passing rate on chest compressions of CPR 3 months after training was 27% (p<.001), on ventilation was 2.63% (p>.001). The error items with statistically significant differences 3 months after CPR training were too little ventilation (74.36%) and too little chest compressions (92.31%). The results of the study suggest that we need further evaluation of course components which could improve retention of CPR for all trainees.

  • PDF

A Study on the Collar Construction Factors of the Women's Tailored Jacket (여성복 테일러드 재킷의 칼라제작요인에 관한 연구)

  • Kim, Gu-Young;Kim, Yeo-Sook
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.947-954
    • /
    • 2008
  • The purpose of this research is to find out related factors to obtain the best collar pattern of the women's tailored jacket by analyzing the difference of the shapes between the drafted pattern and that of being stitched. The experimental conditions established are as follows. The position and angle of its break point, the notch and the width of the collar and lapel are kept unchanged. The collar decrease in neckline edge and the top collar larger than the under collar. The crossing point of gorge line is changed to make the collar's roll line straight. When the pattern is changed to make the outline of the lapel straight, the amount of cloth is changed too. According to the experimental conditions, The experimental clothes using muslin were made to. put on the manikin and the suitable methods of making the collar pattern were decided. In order to find out the influence of fabric materials on the jacket' shapes, Three kinds of wool fabrics were used and the results were evaluated. Summary of the research is as follows. When 0.5cm of the neckline edge is shortened, the standing part of the collar has less wrinkles, and its position looks natural and lastly, the material has slightly affected the collar's condition. It is desirable to make the top collar 0.2cm longer than the under collar. But the length should be different according to the fabric material. It it is thick cloth, the length has to be extended. To make the roll line straight, 0.4cm of the crossing point of gorge line should be corrected. The thick cloth needs more correction. To make the lapel's outline straight, it needs outwardly round 0.2cm more and materials make little difference to affect the shape.

Body Shape Measurement Using Stereo Photo (입체사진을 위용한 인체형상계측)

  • Choe, Hyeok-Ju;Seong, Gyeong-Hwa;Lee, Hyeon-Jik
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.5
    • /
    • pp.664-675
    • /
    • 1998
  • The purpose of this study was to isolate the observational error included in plane photogrammetric data and suggest more accurate and suitable method for body shape measurement. Three experiments were carried out in this study. First of all, the variables which can be obtained from photogrammetric method were selected among the data which can be measured improperly by direct measurement or showing large deviations between the samples. Secondly, the height, the width and the depth of 50 subjects were measured by plane photogrammetry. The result showed that plane photogrammetric data contain significant observational error even for the same variables, as the angle of which photos had been taken changes. Therefore, in order to reduce the observational error and to measure the human body accurately, three-dimensional measurement, stereo photogrammetry was employed in the last experiment. As it is important to isolateonly the observational error by plane photogrammetry and to exclude the accidental error caused by movement of human body subject, body shape model(manikin) was used as subject. The result showed that the average observational error by plane photogrammetry was more than 4 cm in the height, 0.85-1.29cm in the width and 0.49cm in the depth. In conclusion, it is not adequate to use the height obtained from plane photogrammetric data as human body measurement data. And the width and the depth should be used cautiously, even though they are relatively less significant, the error still can make some difference on clothing construction.

  • PDF

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.