• Title/Summary/Keyword: Mandibular first premolars

Search Result 89, Processing Time 0.031 seconds

Estimation of Mandibular Third Molar Development Using the Correlation in Dental Developmental Stages (치아 발육 단계의 상관관계를 이용한 하악 제3대구치 발육 평가)

  • Junyoung Kim;Hyuntae Kim;Teo Jeon Shin;Hong-Keun Hyun;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Ji-Soo Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.4
    • /
    • pp.373-384
    • /
    • 2023
  • This study aims to confirm the average chronologic age according to the developmental stages of the mandibular canine (L3), first and second premolars (L4, L5), and second and third molars (L7, L8) in children and adolescents, and to confirm the developmental stage of L3, L4, L5, and L7, which can estimate the development of L8. A total of 1,956 digital panoramic radiographs of healthy individuals aged between 6 and 15 years who visited Seoul National University Dental Hospital from January 2019 to December 2020 were selected. The developmental stages of L3, L4, L5, L7, and L8 on both sides were evaluated using the dental maturity scoring system proposed by Demirjian and Goldstein. The average age at which the follicle of L8 was first observed was around 9.34 ± 1.35 years and varied from 6 to 12 years. The possibility of agenesis of L8 was high when no traces of L8 were observed after the following stages: L3, L4, and L5 at the developmental stage F and L7 at the developmental stage E; the age was about 10 years. In estimating the development of L8, when only one tooth was considered, estimation accuracy with L5 was the highest, and there was no significant difference when all four teeth were included. This study showed the age distribution according to the developmental stages of L3, L4, L5, L7, and L8 in children and adolescents and confirmed the developmental stages of L3, L4, L5, and L7, which can be used to estimate the development of L8.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Scintigraphic Evaluation of Alveolar Bone Following Dental Implantation in Dogs (개에서 치아 임플란트 식립후 치조골의 신티그라피 평가)

  • Kim, Joong-hyun;Lee, Jae-yeong;Kim, Myoung-hwan;Lee, Won-guk;Kang, Seong-soo;Choi, Seok-hwa
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.2
    • /
    • pp.289-294
    • /
    • 2003
  • This study aimed to determine of osseointegration following dental implantation in the dog mandible using bone scintigraphy. Five mongrel dogs, weighing approximately 8.5 kg and averaging 1.8 years of age, without active periodontal disease were used. During the entire study period, all dogs were fed a soft commercial diet and water ad libitum to minimize functional loading of the implant. Titanium alloy implant systems 10 mm in length and 4 mm in diameter were chosen for insertion. Twelve weeks prior to implantation, the second and third left mandibular premolars in each dog were extracted for the dental implant insertion. Before the dental implantation procedures and 0, 4, 8, and 12 weeks after the insertions, clinical observation, radiography and bone scintigraphy were conducted. The scintigraphy was obtained using a large field of view gamma camera equipped with a paralled-hole, low-energy collimator about 3 hours after intravenous injection of Tc-99m-MDP (8 mCi/dog) to the dogs. There were not inflammation sign after insertion of dental implants on the mandible in dogs. Implants were slightly movable at the first and fourth weeks, and there was no mobility after 8 weeks. Twelve weeks after dental implantation, the bone uptake scintigraphy of peri-implant bone was similar to that of normal alveolar bone, indicating that peri-implant bone was completely regenerated by new bone. In conclusion, we recommend stable implant fixation with alveolar bone for the accurate and safe repair of teeth loot due to decacy, trauma or peridontal disease. Titanium alloy implants were optimal due to their biocompatibility.

A study of the panoramic radiographic images of the buccolingual dilaceration (협설만곡치아의 파노라마방사선영상소견에 대한 연구)

  • Kim, Young-Ho;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.39-44
    • /
    • 2010
  • Purpose : We want to identify the appearance of the buccolingual root dilaceration teeth in the panoramic views and specify the characteristics of these teeth. Materials and Methods : One thousand-six patients were examined on the basis of both panoramic and CT image criteria. We diagnosed and excluded certain teeth from the samples; both prosthodontic or pathologic lesion appearing teeth and mesiodistally dilacerated ones. We meticulously discerned buccolingually dilacerated teeth in the CT images and total 48 samples were selected. The degree of severity in dilaceration was standardized by 2 types of criteria. The samples were differentiated into 3 groups and again categorized into six types showing from the panoramic views: irregular view on the root apex area, clear blunt on the root tip, stepping on root tip, double lamina dura or double tip, arrow-target shaped root, bull's eye, normal view. Results : The types of teeth selected from total 48 buccolingual root dilaceration samples were mandibular first and second molar, premolars, canines, and lateral incisors. The direction of dilaceration was an even percentage to each buccal and lingual side for most selected teeth, however, that of both canines and lateral incisors were directed in almost a buccal side. In the panoramic views, the root types of the buccolingually dilacerated teeth were irregular view on the root apex area, clear blunt on the root tip, stepping on root tip and normal types were almost always normal view. The more severity in dilareated degree, the more chances of observation in the panoramic views were clear blunt on the root tip and stepping on root tip. Conclusion : As observed in the shape of stepping on root tip or double lamina dura in the panoramic views, there can be much more probability to diagnose as a buccolingually dilacerated root.

THE EFFECTS OF DECALCIFIED FREEZE-DRIED BONE AND SYNTHETIC BONE GRAFTS ON REGENERATION OF ALVEOLAR BONE DEFECTS IN DOGS (탈회동결건조골과 합성골이식재가 치조골 결손부 재생과정에 미치는 영향)

  • Choi, Seong-Je;Kwon, Young-Hyuk;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.3
    • /
    • pp.671-689
    • /
    • 1994
  • The purpose of this study was to compare effects of various bone grafts on periodontal regeneration of alveolar bone defects in dogs. Seven adult dogs aged 12 to 18 months were used in this study. Experimental alveolar bone defects were created surgically with a #1/2 round bur at the furcation area of the buccal surface of the mandibular 3rd, 4th premolars and 1st molar. Each experimental alveolar bone defects were grafted with dense hydroxyapatite, natural coral, and decalcified freeze-dried bone, and respectively divided into DHA, NC, DFDB group. An area without bone graft was divided into control group. At 1,2,4,6, and 12 weeks, dogs were serially sacrificed and specimens were prepared with Hematoxylin-Eosin stain and Mallory stain for light microscopic evaluation. The results of this study were as follows : 1. In control group, the matrix change of granulation tissue was observed at 1 week. And in experimental groups, the appearance of connective tissue around graft materials was loosely formed at 1 week, but densely formed at 2 weeks. 2. In every group, the slight formation of new trabecular bone was seen from remaining bone at 1 week. 3. The DHA and NC particles were gradually encapsulated by new trabecular bone from remaining bone, and the osteoid tissue was directly induced from DFDB particles. 4. The presence of osteoblasts was first observed at 1 week in control group and at 2 weeks in NC group, but at 6 weeks in DHA group. 5. In DHA group, the resorption of particles was not observed until 12 weeks. But in NC and DFDB group, the particles were resorbed at 6 weeks and replaced by new bone. And the amount and size of particles were reduced, and their border represented irregular form. In summary, in three experimental groups the inflammatory or foreign body reaction were slight, but the regeneration of new osteoid tissue and the matrix change of dense connective tissue fiber were observed. Especially, NC and DFDB materials were considered as the biocompatible graft materials which were effective in the regenertion of new bone.

  • PDF

AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS (II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구)

  • Lee, Kye-Hyuck;Hur, Seung-Myun;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.