• 제목/요약/키워드: Mandibular condyle fracture

검색결과 81건 처리시간 0.026초

하악 과두 골절의 개방 정복 시 근위 골편의 수복법 (A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle)

  • 김명국
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

하악골의 부위별 충격시 발생되는 응력에 대한 유한 요소법적 연구 (STRESS ANALYSIS OF A HUMAN MANDIBLE UNDER VARIOUS LOADS USING FINITE ELEMENT METHOD)

  • 김성래;박태원
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.7-22
    • /
    • 1992
  • The stress distributions on a human mandible for 18 load cases under two different boundary conditions (mouth open and closed), using the three dimensional finite element modeling were studied. Also, the expected fracture loads for each load cases were calculated by using the Von-Mises yield criterion. The model of a mandible with all teeth was composed of 2402 hexahedron elements and 3698 nodes. CAD techniques were used to analyze the 3-dimensional results. The conclusions of this study were as follows: 1. In the mouth open state, the maximum stress occured at the condyle neck; when the lateral load was exerted, the maximum stress occured at the load side condyle. 2. In the mouth closed state, when the loads were exerted on the mandibular body and chin, the maximum stress occured at the loaded area, and when the loads were exerted on the angle and ramus, the maximum stress occured at the condyle neck. 3. The expected fracture loads in each load case were calculated using the Von-Mises yield criterion, and it was confirmed that the mandible in the mouth open state was more easily fractured than that in the mouth closed state, and the expected fracture loads are lesser in the cases that load direction is parallel at mandibular plane than 45°. 4. The magnitudes of the expected fracture loads increased in the order of angle, ramus, body and chin in case of the mouth closed state, while chin, body, angle and ramus in case of the mouth open state. 5. The Von-Mises stress concentration regions analyzed by F.E.M. corresponded well with the results of clinical studies.

  • PDF

흡수성 스크류를 이용한 하악과두 골절의 치료 (TREATMENT OF CONDYLE FRACTURE WITH RESORBABLE SCREW)

  • 여인범;민승기;오승환;권경환;최상문;박상규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.559-564
    • /
    • 2006
  • According to the development of operation technique and biologic materials, oromaxillofacial surgery department have used many kinds of metal and biologic materials in ORIF and plastic surgery. In maxillofacial fracture, ORIF with metal plate and screw have short healing period and good prognosis. But ORIF with metal materials have many complications as maxillofacial abnormal growth, screw loosening, bone malunion. And metal materials have not used in infection site. The purpose of this study is to evaluate the clinical value of 10 condylar fracture patients operated with absorbable screw at Wonkwang university. Ten patients(8 males, 2 female, mean aged 28) who had mandibular condyle process fracture treated with PLLA implants(poly-l-lactide) was recalled for follow-up clinical and radiologic examination for 10 years. Mouth opening recorvered to more than 35mm and occlusion was stable in all patients. All fractured mandibular condyles showed anatomic good reduction and long-term stability with the use of resorbable miniplates and screw. Bone healing was satisfactory in all patients, and there was no evidence of abnormal resorption of condylar process.

Open versus closed treatment for extracapsular fracture of the mandibular condyle

  • Lee, Junyeong;Jung, Hee-Yeoung;Ryu, Jaeyoung;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권5호
    • /
    • pp.303-308
    • /
    • 2022
  • Objectives: Selection of treatment methods for mandibular condylar fractures remains controversial. In this study, we investigated treatment methods for condylar fractures to determine the indications for open or closed reduction. Patients and Methods: Patients >12 years of age treated for mandibular condylar fractures with a follow-up period of ≥3 months were included in this study. The medical records of enrolled patients were reviewed for sex, age, fracture site, treatment method (open or closed reconstruction), postoperative intermaxillary fixation period, operation time, and complications. Radiological analysis of fracture fragment displacement and changes in ramal height difference was performed using computed tomography and panoramic radiography. Results: A total of 198 patients was investigated, 48.0% (n=95) of whom underwent closed reduction and 52.0% (n=103) underwent open reduction. There was no significant correlation between reduction method and patient sex, age, or follow-up period. No statistically significant difference between the incidence of complications and treatment method was observed. None of the patients underwent open reduction of condylar head fracture. Binary logistic regression analysis showed that open reduction was significantly more frequent in patients with subcondylar fracture compared to in those with a fracture in the condylar head area. There was no statistically significant correlation between the groups and fracture fragment displacement. However, there was a significant difference between the treatment groups in amount of change in ramal height difference between the fractured and the non-fractured sides during treatment. Conclusion: No significant clinical differences were found between the open and closed reduction methods in patients with mandibular condylar fractures. According to fracture site, closed reduction was preferred for condyle head fractures. There was no significant relationship between fracture fragment displacement and treatment method.

Isolated tympanic plate fracture detected by cone-beam computed tomography: report of four cases with review of literature

  • Kalaskar, Ashita Ritesh;Kalaskar, Ritesh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권5호
    • /
    • pp.356-360
    • /
    • 2017
  • The tympanic plate is a small part of the temporal bone that separates the mandibular condyle from the external auditory canal. Fracture of this small plate is rare and usually associated with other bony fractures, mainly temporal and mandibular bone. There is a limited amount of literature on this subject, which increases the chance of cases being overlooked by physicians and radiologists. This is further supported by purely isolated cases of tympanic plate fracture without evidence of other bony fractures. Cone-beam computed tomography is an investigative three-dimensional imaging modality that can be used to detect fine structures and fractures in maxillofacial trauma. This article presents four cases of isolated tympanic plate fracture diagnosed by cone-beam computed tomography with no evidence of fracture involving other bones and review of the literature.

A follow-up study on extracorporeal fixation of condylar fractures using vertical ramus osteotomy

  • Park, Sung Yong;Im, Jae Hyoung;Yoon, Seong Hoe;Lee, Dong Kun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권2호
    • /
    • pp.76-82
    • /
    • 2014
  • Objectives: The aim of this study is to report the results of extracorporeal fixation in patients with mandibular condylar fractures and compare them with the clinical results of conservative treatment. Materials and Methods: The medical records of 92 patients (73 male [M] : 19 female [F], age 13-69 years, mean 33.1 years) treated for condylar fractures at the Department of Oral and Maxillofacial Surgery in Sun Dental Hospital (Daejeon, Korea) from 2007 to 2012 were reviewed. Patients were divided into three groups: group A (23 patients; M : F=18 : 5, age 21-69 years, mean 32.6 years), treated with extracorporeal fixation; group B (30 patients; M : F=24 : 6, age 16-57 years, mean 21.1 years), treated by conventional open reduction; and group C (39 patients; M : F=31 : 8, age 16-63 years, mean 34.4 years), treated with the conservative method ('closed' reduction). Clinical and radiographic findings were evaluated and analyzed statistically. Results: Occurrence of postoperative condylar resorption correlated with certain locations and types of fracture. In this study, patients in group A (treated with extracorporeal fixation) did not demonstrate significant postoperative complications such as malocclusion, mandibular hypomobility, temporomandibular disorder, or complete resorption of condyle fragments. Conclusion: In superiorly located mandibular condyle fractures, exact reconstruction of condylar structure with the conventional open reduction technique can be difficult due to the limited surgical and visual fields. In such cases, extracorporeal fixation of the condyle using vertical ramus osteotomy may be a better choice of treatment because it results in anatomically accurate reconstruction and low risk of complications.

Simultaneous surgery for subcondylar fracture and prominent angle of the mandible

  • Jeong, Chang-Hwa;Ryu, Jae-Young;Lee, Woo-Yul;Kim, Hyeon-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.26.1-26.4
    • /
    • 2015
  • We experienced a patient of subcondylar fracture who had a squared contour of the lower face with prominent angle of the mandible and masseter hypertrophy. Our patient was increasingly seeking esthetic improvement of the lower third of the face. But she did not want multi-stage operations. Thus, we decided and performed a one-stage mandibular angle ostectomy with fracture management. We have a stable and esthetic result simultaneously despite fractures of the fixation plates during follow-up period, so report a case.

Characteristics of temporomandibular joint structures after mandibular condyle fractures revealed by magnetic resonance imaging

  • Kim, Bong Chul;Lee, Yoon Chang;Cha, Hyung Seok;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.24.1-24.7
    • /
    • 2016
  • Background: This study aimed to evaluate the structural changes of temporomandibular joint immediately after condylar fractures with magnetic resonance imaging (MRI). Method: We evaluated 34 subjects of condylar fractures with MRI. The position, shape, and signal intensity of the condyle, disc, and retrodiscal tissue were analyzed with MR images. Results: Immediately after trauma, the disc was displaced with the fractured segment in almost all cases. And, the changes of signal intensity at the retrodiscal tissue were found but less related to the degree of fracture displacement. And, the high signals were observed almost at all fractured joint spaces and even at some contralateral joints. Conclusions: The displaced disc as well as the increased signal intensity of the joint space, condylar head, and retrodiscal tissue demands more attention to prevent the possible sequela of joint.

하악과두골절을 동반한 하악과두의 동맥류성골당 (Aneurysmal bone cyst of the mandibular condyle with condylar neck fracture)

  • 유재정;박정훈;강주한;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제39권4호
    • /
    • pp.205-208
    • /
    • 2009
  • Aneurysmal bone cyst (ABC) is relatively rare, non-neoplastic expansile lesion of bone. The case of a IS-year-old male with a ABC of the left mandibular condyle is presented. Panoramic radiograph showed a unilocular radiolucency with thinned coritces and a subcondylar fracuture which was due to the trauma. Computed tomography (CT) revealed expansile lesion which had similar attenuation soft tissue. The patient was treated surgically including iliac crestal bone graft.

  • PDF

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.