• Title/Summary/Keyword: Management of Medical Equipment

Search Result 314, Processing Time 0.026 seconds

Study on Factors Influencing Purchase Intention of Medical Device -Focusing on ENT Unit- (의료기기 구매의도에 영향을 미치는 요인 -이비인후과 유니트(Unit)를 중심으로-)

  • Lee, Gil-Woo;Kim, Seung-Baum;Kim, Young-Bae;Kim, Dou-Young
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.1
    • /
    • pp.125-132
    • /
    • 2011
  • In this study investigated what buyers want and expect from medical equipment industry. In this study we found as fellows, (a) The quality of instrument is the most important factors that lead to customer purchase intent and brand image follwed by reliability and efficiency in order; (b) Customers perception of company did not show any meaningful relationship with brand image suggesting company positive image perceived by the customers would not necessarily have a positive impact on brand image. Rather, if brand image customer perceived gets higher, considerably higher purchase intention was observed. Therefore, the findings from the present study suggest that medical instrument manufactures need to focus more on providing a long-term high quality of service marketing strategy to increase customer satisfaction and purchase intent in this competitive business environment.

A Study on the Caregiving and Adaptation in the Families who Awarded on Filial Piety (효행자 가족의 부양과 적응에 관한 연구)

  • 김서연
    • Journal of Families and Better Life
    • /
    • v.17 no.2
    • /
    • pp.75-92
    • /
    • 1999
  • The purpose of this study was to investigate the caregiving and adaptation in families who awarded on filial piety. Using the qualitative methods-in depth interview genogram ecomap participation observation- 8 families were analyzed The major findings can be summarized as follows (1) These families showed very high family solidarity with strong collectivity. Their family role was interchangable and their familiarity was passed down from generation to generation. (2) Family members showed similar coping patterns on the basis of their own adaptationl Their coping was inclined toward acceptance especially religioous rather than emotional-focused ad hardly avoidance coping. (4) Although their economic emotional and service cares were family-centered with helps from their extended family household equipment for elder care was not prepared. (5) These families preferred to maintain this condition rather than to be well adapted. It was concluded that to help failed elder's family care iving social support program should be complemented in family life enrichment program for their children medical care program equipment rental program for elder in social network religion program and so on, Social norms forparent-children relation has be changed to more flexible care pattern. Also more social-emotional support has to be given to these families.

  • PDF

Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision (고정밀도의 단상전파정류형 X선 장치의 제작 및 평가)

  • Han, Dong-Kyoon;Jung, Jae-Eun;Choi, Jun-Gu;Seoun, Youl-Hun;Ko, Shin-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.413-419
    • /
    • 2011
  • Diagnosis X-ray equipment localized at 1950's but it is developed suddenly at 1960's with demand together. Manufacture of Diagnostic X-ray equipment is controled by the KS regulation and the Ministry of Health and Welfare because of hazardous element etc. exposure by radiation. Most of diagnostic X-ray equipment ware single phase and three phase full-wave rectification but from 1980's it transforms it was exchanged in inverter type X-ray equipment. Inverter type X-ray equipment produces approximately 50~80% more average photon intensity then single phase full-wave rectification and the accuracy is high. But from a clinic it dose not use because expensive therefor the efficiency improvement of single phase full-wave rectification is necessary. We produced single phase full-wave rectification X-ray equipment control unit, high tension transformer, filament heating transformer, rectification circuit, high tension cable and others and evaluated efficiency, in result which is excellent compare with Rule of Safety Management and KS regulation.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

How the domestic industry of Costa Rica became more competitive in the US market. Antecedents and Trends

  • Pena-Vinces, Jesus C.;Castro, Segundo;Espasandin-Bustelo, Francisco
    • Journal of Distribution Science
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2013
  • Purpose - The aim of this work is to study the reorientation that the export industrial sectors in Costa Rica have experienced during the last 20 years. Research design, data, methodology - The study employs the Cluster Analysis with the export data (20 years of cut-off period) from Costa Rica to the U.S-market. To make the predictions, the technique of the time series was used, with official data (from 2001 to 2010) from the U.S. Department of Commerce and the U.S. International Trade Commission. Results - The Cluster Analysis, show how the economic sectors of traditional products exports of Costa Rica have progressively become in exporters of non-traditional products, meanwhile,the time series confirms that this trend will continue, at least during the next five years. Conclusions - The industry of traditional products exports of Costa Rica (dressmaking, vegetables, coffee, mate, species, etc.) will progressively become in exporters of non- traditional products with a high-tech component (i.e., mechanical equipment and devices, electronic devices and medical equipment),as a consequence of the Chinese (Costa Rica's main competitor) economy's presence in the Organization for Economic Co-operation and Development (OCDE). This fact has enabled the potential improvement of Costa Rica's international competitiveness in the U.S. market.

  • PDF

Radiological Accident and Acute Radiation Syndrome (방사선 사고와 급성 방사선 증후군)

  • Roh, Hyung-Keun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.2
    • /
    • pp.39-48
    • /
    • 2011
  • In mass casualty situation due to radiological accidents, it is important to start aggressive management with rapid triage decisions. External contamination needs immediate decontamination and internal contamination should be treated with special expertise and equipment to prevent the rapid uptake of radionuclides by target organs. Acute radiation syndrome shows a sequence of events that varies with the severity of the exposure. More severe exposures generally lead to more rapid onset of symptoms and severe clinical findings. After the massive exposure, various systems of the body reflect their severe damages that can lead to death within hours or up to several months. The disease progression has classically been divided into four stages: prodromal, latent, manifest illness, and recovery or death. Three characteristic clusters of symptoms including the hematopoietic syndrome, the gastrointestinal syndrome and the cerebrovascular syndrome are all associated with the acute radiation syndrome. The standard medical management of the patients with a potentially survivable radiation exposure includes good medical, surgical and supportive measures. Specific treatment with cytokines and bone marrow transplantation should be considered. The management of internal contamination is much the same as the treatment of poisoning. The standard decontamination should be applied to reduce uptake, and the chelating agents can be administered to enhance the clearance of radioisotopes. Radioactive iodine ($^{131}I$) as one of the nuclear fission products can increase the incidence of thyroid cancer in children. Potential benefit of potassium iodide prophylaxis is greater especially in neonates, infants and small children.

  • PDF

Measuring Expectations in Assessment of Consumer Satisfaction by SERVQUAL (기대수준 측정방법에 따른 고객만족도 측정에 관한 연구 - SERVQUAL 척도를 중심으로 -)

  • 이선희;최귀선;강명근;조우현
    • Health Policy and Management
    • /
    • v.10 no.3
    • /
    • pp.155-168
    • /
    • 2000
  • The SERVQUAL scale is based on the gap theory, which indicates the difference between consumers' expectations and their actual performance. In SERVQUAL scale, the expectations are defined as a "feasible ideal point"(ex, An Excellent hospital has up-to-date equipment). But empirical research identified important problems concerning the conceptual definitions of expectations. They suggests the usage of "desired expectations". Desired expectations are defined as the level at which the consumer predict the service that the organization they visited will perform(ex, $\bigcirc\bigcirc$ hospital has up-to-date equipment). The purpose of this study was to compare the feasible ideal point expectations with desired expectations in assessment of consumer expectations using SERVQUAL scale. We developed two types of questionnaires : (1) to measure feasible ideal point expectations, (2) to measure desired expections. Questionnaire were distributed to ambulatory patients who used the medical service. Total 329 patients participated the hosiptal satisfaction questionnaire(167 for feasible ideal point expectations, 162 for desired expectations). The major finding is as follows: (1) the SERVQUAL scale which was computed by the feasible ideal point showed the higher explanatory power in consumer satisfaction ($R^2$=0.26) than the other identified alternatives(desired expectation, $R^2$=0.11) The results of a study suggests that the feasible ideal point were more conceptually suitable to assess of consumer satisfaction using SERVQUAL scale.SERVQUAL scale.

  • PDF

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

A Study of Institutional Status of Risk Management for Radiotherapy in Foreign Country

  • Lee, Soon Sung;Shin, Dong Oh;Ji, Young Hoon;Kim, Dong Wook;An, Sohyoun;Park, Dong-Wook;Cho, Gyu Suk;Kim, Kum-Bae;Koo, Jihye;Oh, Yoon-Jin;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.139-145
    • /
    • 2016
  • With the development in field of industry and medicine, new machines and techniques are being launched. Moreover, the complexity of the techniques is associated to an increasing risk of incident. Especially, a small error in radiotherapy can lead to a serious patient-related incident, risk management is necessary in radiotherapy in order to reduce the risk of incident. However, in field of radiotherapy, there are no legally binding clauses for risk management and there is an absence of risk management systems at an institutional level. Therefore, we analyzed institutional status of risk management, reporting & classification systems, and risk assessment & analysis in 31 countries. For risk management and reporting systems, 65% of countries investigated had legislation or regulations; however, only 35% of countries used classification systems. It was found that 43% more countries had legislation for risk management in healthcare than those for radiotherapy; 19% more countries had reporting systems for healthcare than those for radiotherapy. For classification systems, 60% more countries had legislation, recommendation, and guidelines in the field of radiotherapy than those for healthcare. Recently, international institutes have published several reports for risk management and patient safety in radiotherapy, owing to which, countries adopting risk management for radiotherapy will gradually increase. Before adopting risk management in Korea, we should precisely understand the procedures and functions of risk management, in order to increase efficiency of risk management because classification & reporting system and risk assessment & analysis are connected organically, and institutional management is needed for high quality of risk management in Korea.

A Study on Development way of Fire fighting 119 angers of Jeju Islander (제주도민의 119화를 위한 소방의 발전방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.147-178
    • /
    • 2003
  • In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations : Building up security system along with operational expansion, building up a system for emergency medical treatment, buliding up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119, we can review the following considerations : Improving the education for fire fighting trainging corps under Jeju Provicial Fire and disaster management department, providing rescue members with more opportunity for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. Provide little more superior quality high fire fighting service to jeju islander, and need long-term and elaborate research to correspond in rising fire fighting man-power demand newly and investment. Construction of well-matched disaster administration system is assignment that must hurry in international free city. That jejudo receives time factor about that is received for another thing area's number of persons or equipment when regional special quality large scale or disaster happens is that of course the support receives limitation immediately. Jeju fire fighting services is one story reform, specialization taking into account particular situation of jeju area to grow as sightseeing and center of culture intending international free city, should be upgraded. So, it may do big contribution naturally in jeju international free city phase that coincide jeju islander's social welfare promotion and safety desire.

  • PDF