• Title/Summary/Keyword: Malmo University

Search Result 5, Processing Time 0.02 seconds

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Effects of enamel matrix derivatives on the proliferation and the release of growth factors of human periodontal ligament cells (법랑기질유도체가 인간 치주인대세포의 증식 및 성장인자 발현에 미치는 영향)

  • Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.203-209
    • /
    • 2016
  • Purpose: Stimulating the proliferation and migration of periodontal ligament cells (PDLCs) has become the main goal of periodontal regeneration. To accomplish this goal, regeneration procedures have been developed, but results have not been predictable. Recently, tissue engineering using enamel matrix derivatives (EMDs) and growth factors has been applied to periodontal regeneration; however, the mechanism of EMDs is largely unknown. The aim of this study was to investigate the effects of EMDs on the proliferation and release of growth factors from PDLCs. Materials and methods: Human PDLCs were removed from individually extracted 3rd molars of healthy young adults, and cultured in the media containing EMDs (Emdogain, Biora, Malmo, Sweden) at concentration of 0, 12.5, 25, 50, 100, and $200{\mu}g/mL$ each. Cell proliferation and ALP (alkaline phosphatase) activity were measured. The evaluation of growth factors released by PDLCs was also performed by one-way analysis of variance (ANOVA) and Bonferroni's multiple comparison test. Results: Significantly increased proliferation and ALP activity were observed in PDLCs treated with over $25{\mu}g/mL$ and $50{\mu}g/mL$ EMDs, respectively. Additionally, treatment of PDLCs with $50{\mu}g/mL$ resulted in significantly increased release of vascular endothelial growth factor (VEGF) and transforming growth factor $(TGF)-{\beta}$ after 24 h and 48 h, respectively. Conclusion: EMDs enhance the proliferation and ALP activity of PDLCs, and promote the release of growth factors, including VEGF and $TGF-{\beta}$, from PDLCs. Therefore EMDs could be one of the effective methods for periodontal regeneration.

Distance of insertion points in a mattress suture from the wound margin for ideal primary closure in alveolar mucosa: an in vitro experimental study

  • Lee, Won-Ho;Kuchler, Ulrike;Cha, Jae-Kook;Stavropoulos, Andreas;Lee, Jung-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • Purpose: This study was conducted to determine how the distance of the near insertion points in a vertical mattress suture from the wound margin influences the pattern of primary closure in an in vitro experimental model. Methods: Pairs of 180 porcine gingival and alveolar mucosa samples were harvested from 90 pig jaws and fixed to a specially designed model. A vertical mattress suture was performed with the near insertion point at 3 different distances from the wound margin (1-, 3-, and 5-mm) on both the gingival and mucosal samples (6 groups; n=30 for each group). The margin discrepancy and the presence of epithelium between the wound margins were measured on histologic slides. Results: The margin discrepancy decreased significantly as the near insertion point became closer to the wound margin both in mucosal tissue (0.241±0.169 mm, 0.945±0.497 mm, and 1.306±0.773 mm for the 1-, 3-, and 5-mm groups, respectively) and in gingival tissue (0.373±0.304 mm, 0.698±0.431 mm, and 0.713±0.691 mm, respectively). The frequency of complications of wound margin adaptation reduced as the distance of the near insertion point from the wound margin decreased both in the mucosal and gingival tissues. Conclusions: Placing the near insertion point close to the wound margin enhances the precision of wound margin approximation/adaptation using a vertical mattress suture.

Conditions for a Sustainable Cooperation Model of 'Local Government-University': Focusing on Case Studies Both in Domestic and Foreign (지속가능한 '지자체-대학' 협력모델의 조건: 국내외 사례연구를 중심으로)

  • Seyon Park;Kyonghwan Kim
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.337-357
    • /
    • 2023
  • Universities and local governments in Korea are simultaneously experiencing the difficulties of a decrease in the youth population and a decrease in the school-age population, and close cooperation between universities and local governments is urgently needed to solve this problem. Representative methods of such cooperation include the establishment of a regional innovation system and the theories of innovation clusters and triple helix models. In addition to these theories, the aim is to derive sustainable conditions for the local government-university cooperation model by examining various cases of cooperation at home and abroad. This is the purpose of this paper. In particular, through case studies of cooperation between local governments and universities at home and abroad, three types of models (job, education, and housing) were analyzed, and common conditions and requirements for sustainable cooperation were proposed. In order for cooperation between local governments and universities to continue and produce successful results, mutual benefit creation, infrastructure construction and operation appropriate for capabilities, flexibility, and mutual responsibility are necessary. Furthermore, a model that suits the capabilities of local governments and universities must be found, and in this process, the university's research capabilities and commercialization capabilities of research results are especially important. In addition, it is essential to establish a new cooperation system between local governments, universities, and the central government.

The Third Version of the Copenhagen Psychosocial Questionnaire

  • Burr, Hermann;Berthelsen, Hanne;Moncada, Salvador;Nubling, Matthias;Dupret, Emilie;Demiral, Yucel;Oudyk, John;Kristensen, Tage S.;Llorens, Clara;Navarro, Albert;Lincke, Hans-Joachim;Bocerean, Christine;Sahan, Ceyda;Smith, Peter;Pohrt, Anne
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.482-503
    • /
    • 2019
  • Introduction: A new third version of the Copenhagen Psychosocial Questionnaire (COPSOQ III) has been developed in response to trends in working life, theoretical concepts, and international experience. A key component of the COPSOQ III is a defined set of mandatory core items to be included in national short, middle, and long versions of the questionnaire. The aim of the present article is to present and test the reliability of the new international middle version of the COPSOQ III. Methods: The questionnaire was tested among 23,361 employees during 2016-2017 in Canada, Spain, France, Germany, Sweden, and Turkey. A total of 26 dimensions (measured through scales or single items) of the middle version and two from the long version were tested. Psychometric properties of the dimensions were assessed regarding reliability (Cronbach α), ceiling and floor effects (fractions with extreme answers), and distinctiveness (correlations with other dimensions). Results: Most international middle dimensions had satisfactory reliability in most countries, though some ceiling and floor effects were present. Dimensions with missing values were rare. Most dimensions had low to medium intercorrelations. Conclusions: The COPSOQ III offers reliable and distinct measures of a wide range of psychosocial dimensions of modern working life in different countries; although a few measures could be improved. Future testing should focus on validation of the COPSOQ items and dimensions using both qualitative and quantitative approaches. Such investigations would enhance the basis for recommendations using the COPSOQ III.