• Title/Summary/Keyword: Mallet finger

Search Result 12, Processing Time 0.015 seconds

Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion (Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료)

  • Kim, Jae Won;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.