• Title/Summary/Keyword: Malfunction Diagnosis

Search Result 75, Processing Time 0.024 seconds

Endoscopic Third Ventriculostomy in Patients with Shunt Malfunction

  • Lee, Seung-Hoon;Kong, Doo-Sik;Seol, Ho-Joon;Shin, Hyung-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.217-221
    • /
    • 2011
  • Objective : This paper presents data from a retrospective study of endoscopic third ventriculostomy (ETV) in patients with shunt malfunction and proposes a simple and reasonable post-operative protocol that can detect ETV failure. Methods : We enrolled 19 consecutive hydrocephalus patients (11 male and 8 female) who were treated with ETV between April 2001 and July 2010 after failure of previously placed shunts. We evaluated for correlations between the success rate of ETV and the following parameters : age at the time of surgery, etiology of hydrocephalus, number of shunt revisions, interval between the initial diagnosis of hydrocephalus or the last shunt placement and ETV, and the indwelling time of external ventricular drainage. Results : At the time of ETV after shunt failure, 14 of the 19 patients were in the pediatric age group and 5 were adults, with ages ranging from 14 months to 42 years (median age, 12 years). The patients had initially been diagnosed with hydrocephalus between the ages of 1 month 24 days and 32 years (median age, 6 years 3 months). The etiology of hydrocephalus was neoplasm in 7 patients; infection in 5; malformation, such as aqueductal stenosis or megacisterna magna in 3; trauma in 1; and unknown in 3. The overall success rate during the median follow-up duration of 1.4 years (9 days to 8.7 years) after secondary ETV was 68.4%. None of the possible contributing factors for successful ETV, including age (p=0.97) and the etiology of hydrocephalus (p=0.79), were statistically correlated with outcomes in our series. Conclusion: The use of ETV in patients with shunt malfunction resulted in shunt independence in 68.4% of cases. Age, etiology of hydrocephalus, and other contributing factors were not statistically correlated with ETV success. External ventricular drainage management during the immediate post-ETV period is a good means of detecting ETV failure.

UV Detecting according to Corona Discharge Intensity using UV Sensor (자외선 센서를 이용한 코로나 방전 강도에 따른 자외선 검출)

  • Kwag, Dong-Soon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.78-83
    • /
    • 2014
  • To minimize the financial loss due to power facility malfunction, on-line diagnostic techniques are required to grasp any abnormal state of facilities in the live line as well as devices to diagnose abnormal states of power facility in an easy and prompt manner. This study aims to develop a portable UV detecting system by means of UV sensors for easier and efficient inspection of the degradation state of power facility in a long distance. Accordingly, it includes a simulation of corona discharges that may occur due to degradation of power facility and detection of ultraviolet pulse generation depending on the corona discharge intensity and measuring distance in application of UV sensors. Additionally, the optimal algorithm is determined for its application to the system's degradation diagnosis program based on the measured experiment data.

Study on the Principle of Diagnosis for the Oneironosus (몽진(夢診)의 원리에 대한 연구)

  • Kang Dong-Yun;Kim Byung-Soo;Kang Jung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1112-1119
    • /
    • 2005
  • The dream is a well-known experience in the routine life. It is necessary to consider the dream to modality of diagnosis because many evidences that the dream represents the physiologic and pathologic changes in the human have been proved in recent days. The oneironosus(病夢) was caused by three factors, which are the external stresses of the body, malfunction of Jang-Bu(臟腑) and irregular of Yin-Yang(陰陽) and Gi-blood(氣血). The oneironosus(病夢) reflects the location, characteristics, progression and prognosis of the disease. In addition, it predicts the development of disease. The principle of treatment for the oneironosus(病夢) is making an effort for the stabilization of mind by eradicating the internal and external factors that make the spirit(神) been unstable.

Improvement in Transformer Diagnosis by DGA using Fuzzy Logic

  • Dhote, Nitin K.;Helonde, J.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.615-621
    • /
    • 2014
  • Power transformer is one of the most important equipments in electrical power system. The detection of certain gases generated in transformer is the first indication of a malfunction that may lead to failure if not detected. Dissolved gas analysis (DGA) of transformer oil has been one of the most reliable techniques to detect the incipient faults. Many conventional DGA methods have been developed to interpret DGA results obtained from gas chromatography. Although these methods are widely used in the world, they sometimes fail to diagnose, especially when DGA results falls outside conventional method codes or when more than one fault exist in transformer. To overcome these limitations, fuzzy inference system (FIS) is proposed. 250 different cases are used to test the accuracy of various DGA methods in interpreting the transformer condition.

Diagnosis Engineering of Grounding System to Reduce Noise Signals (노이즈 저감을 위한 접지시스템 진단 엔지니어링)

  • Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1290-1294
    • /
    • 2016
  • In this study, we investigate the sources of system malfunctions by measuring and diagnosing various surges and noise signals from grounding systems for electrical and electronic systems and installations in order to ensure the reliability and stability of the system operations. We measured performance or structural problems detected in the grounding systems currently in operation and analyzed the measured data in order to eliminate noise currents and interferences causing the systems to malfunction and be damaged. Based on the analysis results, we proposed improving grounding systems and the wiring arrangements most appropriate for the grounding systems and carried out the installations as per the proposed engineering. We verified that the proposed engineering made the status of system operations improved by measuring the ground noise signals during the system operations and comparing them before and after improvements being carried out.

Analysis of Performance Characteristics on Diesel Engine with Aftertreatment and EGR System (후처리 시스템을 장착한 디젤엔진의 EGR 밸브 작동에 따른 성능 분석)

  • Park, Cheol-Woong;Choi, Young;Lim, Gi-Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.124-129
    • /
    • 2010
  • The direct injection (DI) diesel engine has become a prime candidate for future transportation needs because of its high thermal efficiency. However, nitrogen oxides (NOx) increase in the local high temperature regions and particulate matter (PM) increases in the diffusion flame region within diesel combustion. Therefore, the demand for developing hybrid system consist of exhaust gas recirculation (EGR) and aftertreatment system as well as diesel particulate filter (DPF) or lean NOx trap (LNT) should be applied. The variation of EGR rate due to the malfunction of EGR valve can affect not only the combustion stability of engine but also the performance of aftertreatment system. In this research, 2.0 liter 4-cylinder turbocharged diesel engine was used to investigate the combustion and emission characteristics for various operating conditions with EGR. While the fuel consumption was increased with increase of EGR rate, NOx emission was improved by maximum 90% at low speed, low load operating condition. To achieve combustion stability and reliability of aftertrearment system with minimum penalty in fuel consumption and emissions, the fault diagnosis of EGR malfunction must be employed.

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

A Method for Generating Rule-based Fault Diagnosis Knowledge on Smart Home Environment (스마트 홈 환경에서 규칙 기반의 오류 진단 지식 생성 방법)

  • Ryu, Dong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2741-2749
    • /
    • 2009
  • There have been many researches to detect and recover from faults on smart home environment, because these faults should lower its reliability. while, most of these researches have addressed functional defects of devices or software malfunction, few attempts have been made to deal with faults which may occur due to the inter relationships among devices. In this paper, we define the relationships among devices as rules, and propose a method for generating fault diagnosis knowledge which defines the symptoms and causes of faults. We classify the contexts of devices into two sets, depending on whether it satisfies the rules or not. when this method is applied to smart home environment, it is feasible not only to detect faults that may occur due to the relationships among devices but to identify their causes at real time.

Analysis of Diagnosis and Failsafe Algorithm Using Transmission Simulator (변속기 시뮬레이터를 이용한 진단 및 안전작동 알고리즘 분석)

  • Jung, Gyuhong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.89-97
    • /
    • 2014
  • As the digital control technologies in automotive industry have advanced, electronic control units(ECUs) play a key-role to improve system performance. Transmission control unit(TCU) is a shifting controller for automatic transmission of which major functions are to determine the shift and manage the shifting process considering the various sensor signal on transmission and driver's commands. As with any ECU in vehicle, TCU performs complex algorithms such as shift control, diagnostic and failsafe functions. However, firmware design analysis is hardly possible by the reverse engineering due to code protection. Transmission simulator is a hardware-in-the-loop simulator which enables TCU to work in normal mode by simulating the electrical signal of TCU interface. In this research, diagnosis and failsafe algorithm implemented on commercialized TCU is analyzed by using the transmission simulator that is developed for wheel loader construction vehicle. This paper gives various experimental results on the proportional solenoid current trajectories for different operating modes, error detection criterion and limphome mode gears for all the possible cases of clutch malfunction. The derived results for conventional TCU can be applied to the development of inherent TCU algorithms and the transmission simulator can also be utilized for the test of TCU to be developed.

Development of the Vehicle Diagnosis Program Using OBD-II (OBD-II 시스템을 활용한 자동차 고장진단 프로그램 개발)

  • Yoo, Changhyun;Ko, Yongseo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • This paper develops an OBD Diagnostic Program (Program) using Visual Studio (C#), which was used to diagnosis malfunction information from OBD-II system vehicles. We accomplished this using the Program, Diagnostic tests, Board (STN1110), FTDI Basic Cable, Mini USB Cable, OBD Data Cable, and both hybrid and regular vehicles. The Program tests real-time data output, DTC output, sensor value output, engine RPM, waveform data, OBD type check, PID inspection, and whole monitoring. We found vehicles used in this research had 19 PIDs, which was within OBD-II regulations. We also gathered data on control and diagnostic code regulated by OBD-II system, such as, sensor output value, engine RPM, DTC output, each PID analytic value, OBD type, fuel mode, and whole monitoring result value. Using the data collected through the Program appropriately can lead to more effective diagnostic practices and contribute to education.