• 제목/요약/키워드: Main cooling system

검색결과 298건 처리시간 0.027초

미래의 불확실한 냉방부하에 대한 아이스슬러리를 이용한 지역냉방시스템 (A District Cooling System using Ice Slurry for the Uncertain Cooling Load of the Future)

  • 이윤표;안영환;윤석만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.233-238
    • /
    • 2006
  • A new district cooling system using ice slurry for the uncertain cooling load of the future is presented. The chilled water produced by the absorption chillers is used for the base cooling load. The temperature of the chilled water is reduced by mixing of ice slurry depending on increasing of the cooling load. Finally, IPF of the ice slurry is increased up to 10% at the peak load. The transporting mass flow rate is decreased down to 44.7%, and the diameter of the main pipe is decreased down to 66.7%, but the diameter of the branched pipe is designed as the same size of the chilled water.

  • PDF

20 MeV DTL 냉각계통의 유동 특성에 관한 수치해석 (A Numerical Analysis on the Characteristics of Flow in the 20 MeV DTL Cooling System)

  • 김경렬;박준;권세진;김형균;김희섭;황운하;윤종철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2907-2912
    • /
    • 2007
  • The cooling water system for the PEFP 20 MeV proton accelerator was established and tested to obtain the precise resonance frequency of DTL through the temperature control of cooling water. The water temperature in the main flow loop was manipulated by adjusting the proportion of hot water returning from the DTL structures through the heat exchanger loop. Due to low duty factor operation and insufficient cooling loop installation of the DTL tanks, the manual mode operation was applied to maintain the DTL temperatures close to their resonance temperatures. The optimized process conditions with flow balancing and pressure drop in the DTL cooling systems are reported.

  • PDF

피스톤 냉각용 엔진오일 제트 유동특성 (Flow Characteristics of Oil Jet for Cooling a Piston)

  • 리리;이종훈;정호윤;김재환;이연원
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.50-55
    • /
    • 2006
  • An efficient cooling system for a piston of an automotive engine is very important. Therefore a large capacity gasoline engine or diesel engine has adopted the direct injection cooling system to increase its cooling efficiency. In this direct cooling system, an cooling oil is injected to a piston directly using an oil jet and this cooling oil flows through an oil gallery inside the piston. Flow rate and injection accuracy of this cooling oil are very important because these are main factors that have influence on its efficiency. The purpose of this study is to understand the changes of flow characteristics with various curvatures and diameters of an outlet nozzle and to check whether engine oil enters into the oil gallery well or not. From this study, we found that secondary flow was formed in a curved part of jet due to centrifugal force and irregular flow pattern appeared at the jet outlet. This pattern has influence on flow characteristics of engine oil entering the gallery. These simulation results have a good agreement with experiments.

  • PDF

하나로 핵연료 시험루프의 주냉각수 계통 유동해석 (The flow characteristics of a Main Cooling Water System for Nuclear Fuel Test Loop Installed in HANARO)

  • 박용철;이용섭;지대영;안성호;김영기
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.444-447
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor (PWR) or a heavy water power reactor (CANDU). There is an in-pile section (IPS) and an out-pile section (OPS) in this test loop. When HANARO is normally operated, the fuel loaded in the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. The pump can not continuously suck a fluid and not pressurize the fluid during a cold function test. To verify the flow characteristics of the MCWS, a flow net work analysis has been conducted. When the higher elevation pipelines wholly filled with coolant, it was confirmed through the analysis results that the pump pressurized the coolant normally. And the analysis results described the system characteristics with operation temperature and pressure variation satisfactorily.

  • PDF

로봇제어기 냉각시스템분석을 위한 열유동 해석 (Flow and Thermal Analyses for Evaluation of a Robot Controller Cooling System)

  • 조기주;박성원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.414-418
    • /
    • 2001
  • Flow and thermal characteristics of cooling system for the robot controller were numerically as well as experimentally investigated. To obtain the overall flows within controller, the system level solutions were analysed at first and then the board level solutions were pursued to understand the detailed flow and temperature fields near the main board which have a significant influence on the cooling of electronic components. The evaluation for a performance of the heat exchanger was conducted on the basis of the obtained flow and temperature patterns. The results showed that the heat exchanger made a small contribution to the cooling of controller and caused an increase of the temperature in CPU.

  • PDF

PEFP DTL 냉각시스템의 펌프 선정 최적화에 관한 연구 (A Study on the Optimized Pump Selection of the Cooling System for the PEFP DTL Accelerator)

  • 박준;김경렬;김형균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1277-1282
    • /
    • 2009
  • The main objective of this prototype is to control resonance frequency of DTL system through the temperature control of cooling water. It is to resonant frequency of the drift tube cavities to 350 MHz. This paper describes the design of a prototype cooling water skid required for the temperature control of the DTL cavities, focusing in the modeling and simulation of the cooling system, the sizing of water pumping skid component.

  • PDF

냉각계통의 구리 부식 생성물의 화학세정에 관한 연구 (A study on Chemical Cleaning of Copper Corrosion Product in cooling system)

  • 이한철;이창우;현성호
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.140-145
    • /
    • 1999
  • This study was carried out a investigate the effect of chemical cleaning of corrosion product in cooling system made of copper and copper alloy as basic material and used cooling water as pure water. We studied chemical cleaning condition that minimizes the influence on basic material by means of EDTA solution so as to eliminate the slurry in cooling system. As a result, we found that the main components of sludge in cooling system produced by corrosion of copper were $Cu_2O$, CuO, Cu, and Fe. The optimum condition of chemical cleaning was 400 ppm EDTA solution at $60^{\circ}C$.

  • PDF

주기관 쟈케트냉각수 온도를 위한 피드포워드 제어시스템의 구성과 분석 (Configuration and Analysis of a Feed-forward Control System for Jacket Cooling Water Temperature of Marine Prime Diesel Engine)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1303-1308
    • /
    • 2008
  • Keeping cooling water temperature higher within the allowable range helps marine engines to run in more efficient condition especially when the engine load is low. Temperature control of jacket cooling water in outlet side of main engine has been more widely adopted to ships these days for the purpose to reduce fuel consumption rate. But If the temperature sensor for the control loop is placed at the outlet of engine, it brings more difficulties in attaining stable and desirable properties due to dead times included in pipe length and engine itself comparing to the case where the measuring point is at the inlet side of main engine. In relation with this problem, Feed-forward control could be one of realistic solutions as it reveals good properties and requires less cost for system configuration. This study suggests a forward control system which leads to improved temperature control performances to disturbance signals which could arise from variation of engine load or weather condition. Two dead times in the modelling were described, considering pipe length between the actuator and the engine as well as the thermal process inside the engine. The results of analysis were shown by simulations to confirm responses under different conditions.

Desktop PC CPU Cooling System Design and Analysis

  • 최지훈;유정현;서민환;강신제;김천주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.601-604
    • /
    • 2008
  • Desktop PC CPUs have been significantly required to be the necessity of thermal management while they have satisfied the extensive data and graphic processing requirements. So the cooling systems assembled with heat pipes embedded in a metal cooling plate, and fins are widely used in the desktop PC markets. Due to a number of demands such as the confined space of desktop PCs, higher heat density of CPUs, and acoustic noise, however, there is the main drive to improve continuously cooling systems. This paper presents the flow and thermal behavior of the cooling system by using the computational fluid dynamics(CFD) code.

  • PDF

저장조냉각계통의 신뢰성향상을 위한 제어시스템 구현 (The implementation of control system for enhancing the reliability of the cooling system of pool storage)

  • 이철용;변기호;이상정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.367-371
    • /
    • 1990
  • In this paper, a real-time fault tolerant control system has been designed for the cooling system of the spent fuel pool storage. The fault tolerant control system consists of the fault detection part, the redundant actuator part(main and backup pumps) and the controller implemented on programmable. logic controller. This paper considers only the actuator fault whose detection is accomplished using Friedland's separated bias estimation method. This paper also shows the real-time experimental results from which it can be concluded that the designed fault tolerant control system exhibits satisfactory performance.

  • PDF