Assessment of deformations and internal forces in the suspension bridge under eccentric live loads: Analytical algorithm

  • Zhang, Wenming;Lu, Xiaofan;Chang, Jiaqi;Tian, Genmin;Xia, Lianfeng
    • Structural Engineering and Mechanics
    • /
    • 제80권6호
    • /
    • pp.749-765
    • /
    • 2021
  • Suspension bridges bear large eccentric live loads in rush hours when most vehicles travel in one direction on the left or right side of the bridge. With the increasing number and weight of vehicles and the girder widening, the eccentric live load effect on the bridge behavior, including bending and distortion of the main girder, gets more pronounced, even jeopardizing bridge safety. This study proposes an analytical algorithm based on multi-catenary theory for predicting the suspension bridge responses to eccentric live load via the nonlinear generalized reduced gradient method. A set of governing equations is derived to solve the following unknown values: the girder rigid-body displacement in the longitudinal direction; the horizontal projection lengths of main cable's segments; the parameters of catenary equations and horizontal forces of the side span cable segments and the leftmost segments of middle span cables; the suspender tensions and the bearing reactions. Then girder's responses, including rigid-body displacement in the longitudinal direction, deflections, and torsion angles; suspenders' responses, including the suspender tensions and the hanging point displacements; main cables' responses, including the horizontal forces of each segment; and the longitudinal displacement of the pylons' tower top under eccentric load can be calculated. The response of an exemplar suspension bridge with three spans of 168, 548, and 168 m is calculated by the proposed analytical method and the finite element method in two eccentric live load cases, and their results prove the former's feasibility. The nonuniform distribution of the live load in the lateral direction is shown to impose a greater threat to suspension bridge safety than that in the longitudinal direction, while some other specific features revealed by the proposed method are discussed in detail.

단면회전방법을 적용한 강합성 소수주거더 개발 및 실험적 성능 평가 (Development and Experimental Performance Evaluation of Steel Composite Girder by Turn Over Process)

  • 김성재;이나현;김성배;김장호
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.407-415
    • /
    • 2010
  • 현재 국내에서 설계되고 있는 40~70 m 지간의 강도로교 90% 이상이 박스거더교 형식이며 박스거더교는 휨 강성과 비틀림 강성이 뛰어나 장경간이나 곡선을 갖는 교량 형식으로 적합할 뿐만 아니라 가설현장에서의 작업을 최소화 할 수 있어 현장 안전관리 면에서도 유리한 구조형식이다. 그러나 박스거더는 상하 플랜지와 복부판이 수직, 수평보강재로 보강되는 구조로 부재량과 용접량이 많이 소요되어 비경제적인 교량 형식으로 많이 지적되어 왔다. 따라서, 미국이나 일본에서는 상대적으로 부부재를 줄일 수 있는 보다 경제적인 플레이트거더교가 일반적으로 적용되고 있다. 이러한 플레이트거더교의 한 형식인 소수주거더교는 강합성교량의 합리화를 위해 많이 채용되는 형식으로, 주거더 간격을 종래의 3 m 정도에서 2배 정도인 6 m 이상으로 증가하여 주거더의 개수를 최소화시키는 경제적인 교량형식이다. 또한, 거더 단면의 단순화를 위하여 거더의 복부판에 부착되는 수평보강재와 수직보강재를 최대한 생략할 수 있다. 2주거더교는 소수주거더교의 대표적인 형식으로, 유효폭 10 m 전후의 교량에 적합하여 프랑스를 중심으로 유럽에서는 1960년대부터 본격적으로 개발되어왔다. 국내에서는 소수주거더교 적용시 안전율 확보를 위해 유럽이나 일본 등에 비해 많은 강재량을 사용하고 있으며, 설계자들의 친밀도 부족과 박스거더교에 비해 복잡한 설계 등과 같은 여러가지 실무적용 차원에서 적용이 제한되고 있는 실정이다. 이 연구에서는 합리화 강교량 형식인 소수주거더교의 제작방법을 개선하고 구속콘크리트를 활용하여 강교량에서 공사비와 직결되는 강중을 줄일 수 있는 신형식 강합성거더(Turn Over Composite Girder) 구조형식을 제안하고자 한다. 또한 실물 크기인 20 m 단면회전방법을 적용한 강합성 거더시험체 및 교량시험체를 제작하여 제작성을 평가하고 구조성능 실험을 하여 구조안전성을 평가하였다.

Investigation on mechanics performance of cable-stayed-suspension hybrid bridges

  • Zhang, Xin-Jun
    • Wind and Structures
    • /
    • 제10권6호
    • /
    • pp.533-542
    • /
    • 2007
  • The cable-stayed-suspension hybrid bridge is a cooperative system of the cable-stayed bridge and suspension bridge, and takes some advantages and also makes up some deficiencies of both the two bridge systems, and therefore becomes strong in spanning. By taking the cable-stayed-suspension hybrid bridge, suspension bridge and cable-stayed bridge with main span of 1400 m as examples, the mechanics performance including the static and dynamic characteristics, the aerostatic and aerodynamic stability etc is investigated by 3D nonlinear analysis. The results show that as compared to the suspension bridge and cable-stayed bridge, the cable-stayed-suspension hybrid bridge has greater structural stiffness, less internal forces and better wind stability, and is favorable to be used in super long-span bridges.

Wind-induced vibrations and suppression measures of the Hong Kong-Zhuhai-Macao Bridge

  • Ma, Cunming;Li, Zhiguo;Meng, Fanchao;Liao, Haili;Wang, Junxin
    • Wind and Structures
    • /
    • 제32권3호
    • /
    • pp.179-191
    • /
    • 2021
  • A series of wind tunnel tests, including 1:50 sectional model tests, 1:50 free-standing bridge tower tests and 1:70 full-bridge aeroelastic model tests were carried out to systematically investigate the aerodynamic performance of the Hong Kong-Zhuhai-Macao Bridge (HZMB). The test result indicates that there are three wind-resistant safety issues the HZMB encounters, including unacceptable low flutter critical wind speed, vertical vortex-induced vibration (VIV) of the main girder and galloping of the bridge tower in across-wind direction. Wind-induced vibration of HZMB can be effectively suppressed by the application of aerodynamic and mechanical measures. Acceptable flutter critical wind speed is achieved by optimizing the main girder form (before: large cantilever steel box girder, after: streamlined steel box girder) and cable type (before: central cable, after: double cable); The installations of wind fairing, guide plates and increasing structural damping are proved to be useful in suppressing the VIV of the HZMB; The galloping can be effectively suppressed by optimizing the interior angle on the windward side of the bridge tower. The present works provide scientific basis and guidance for wind resistance design of the HZMB.

실습선 새바다호의 선체진동에 관하여 (On the Hull Vibration of the Training Ship Sae-Ba-Da)

  • 박중희
    • 어선
    • /
    • 제29권
    • /
    • pp.15-20
    • /
    • 1986
  • This paper describes on the measurement of the deck vibration produced by the main engine vibration of stern trawler MIS SAE-BA-DA (2,275GT, 3,600PS) while the ship is cruising and drifting. The obtained results are as follows; 1. The deck vibration level was the highest point at vertical line which pass main engine and the lowest point at vertical line which pass top bridge while the crusing. 2. The vibration source level of the main engine, screw shaft and screw propeller were respectively 110, 90 and 80% while the crusing. 3. The main deck vibration pressure level at the check points 2, 20, 30, 40, 60, 70, 80, 86m from the bow to stern was respectively 9, 8, 7, 10, 22, 45, 18, 23%. 4. The frequency distributions of the main engine, screw shaft, screw propeller vibration were from 3Hz to 10KHz, predominant frequency was 1KHz, each vibration accelration the highest level were respectively 1.3, 0.8, 0.5mm/$S^2$. 5. The predominant frequency distributions of the main deck, second deck, bridge deck and top bridge deck's vibration were from 10 to 30Hz, and each vibration accelration level were respe¬ctively 0.7, 0.05, 0.07, 0.04mm/$S^2$.

  • PDF

Conceptual design of light bascule bridge

  • Xu, Weiwei;Ding, Hanshan;Lu, Zhitao
    • Structural Engineering and Mechanics
    • /
    • 제29권4호
    • /
    • pp.381-390
    • /
    • 2008
  • This paper proposed a conceptual design of bascule bridge, which is a new kind of movable bridge with an aim of reducing the weight of superstructure. Compared with the traditional bascule bridge, the light bascule bridge chooses cable-stayed bridge with inclined pylon as its superstructure; therefore, the functions of balance-weight and structure will fuse into one. Otherwise, it adopts moving counterweight to adjust its center of gravity (CG) to open or close the bridge. In order to lighten the superstructure, it uses contact springs to auxiliary retract, and intelligent prestressing system (IPS) to control the main girder's deformation. Simultaneously the vibration control scheme of structure is discussed. Starting from establishing the mechanical model of bridge, this article tries to analyze the conditions that the design parameters of structure and attachments should satisfy to. After the design procedure was presented, an example was also adopted to explain the primary design process of this kind bridge.

Flutter analysis of Stonecutters Bridge

  • Hui, Michael C.H.;Ding, Q.S.;Xu, Y.L.
    • Wind and Structures
    • /
    • 제9권2호
    • /
    • pp.125-146
    • /
    • 2006
  • Stonecutters Bridge of Hong Kong is a cable-stayed bridge with two single-column pylons each 298 m high and an aerodynamic twin deck. The total length of the bridge is 1596 m with a main span of 1018 m. The top 118 m of the tower will comprise structural steel and concrete composite while the bottom part will be of reinforced concrete. The bridge deck at the central span will be of steel whilst the side spans will be of concrete. Stonecutters Bridge has adopted a twin-girder deck design with a wide clear separation of 14.3 m between the two longitudinal girders. Although a number of studies have been conducted to investigate the aerodynamic performance of twin-girder deck, the actual real life application of this type of deck is extremely limited. This therefore triggered the need for conducting the present studies, the main objective of which is to investigate the performance of Stonecutters Bridge against flutter at its in-service stage as well as during construction. Based on the flutter derivatives obtained from the 1:80 scale rigid section model experiment, flutter analysis was carried out using 3-D finite element based single parameter searching method developed by the second author of this paper. A total of 6 finite element models of the bridge covering the in-service stage as well as 5 construction stages were established. The dynamic characteristics of the bridge associated with these stages were computed and applied in the analyses. Apart from the critical wind speeds for the onset of flutter, the dominant modes of vibration participating in the flutter vibration were also identified. The results indicate that the bridge will be stable against flutter at its in-service stage as well as during construction at wind speeds much higher than the verification wind speed of 95 m/s (1-minute mean).

다경간 현수교 주탑 설계를 위한 등가 현수교 모델 (Equivalent Suspension Bridge Model for Tower Design of Multi-span Suspension Bridges)

  • 최동호;나호성;이지엽;권순길
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.669-677
    • /
    • 2011
  • 다경간 현수교란 3개 이상의 주탑을 가지는 현수교로 중앙부에 주 경간을 2개 이상 가지는 현수교이다. 다경간 현수교 설계시 중앙주탑과 측주탑의 적절한 강성비를 가지도록 설계하는 것이 경제성이나 구조적인 효율성 측면에서 중요하다. 본 연구는 다경간 현수교의 중앙주탑과 측주탑의 적절한 강성비를 찾기 위해 다경간 현수교의 거동을 용이하게 파악할 수 있는 간편한 방법을 제안하는 것을 목적으로 하고 있다. 그 방법으로 다경간 현수교의 주케이블을 등가의 케이블 스프링으로 이상화하고, 주케이블에 작용하는 장력을 주탑상단에 수평력과 수직력의 외력으로 치환시키는 방법으로 다경간 현수교를 등가 다경간 현수교 모델로 치환하였다. 등가 다경간 현수교 모델에 대한 평형방정식을 유도하고 비선형해석을 통해 방정식의 해를 구하였다. 중앙지간장 3,000m의 4경간 현수교의 FEM 해석을 통해 각 주탑에서 발생하는 변위와 모멘트 반력을 계산하고, 이 결과를 등가 4경간 현수교 모델의 해석결과와 비교하여 본 연구의 연구결과를 검증하였다. 검증 결과, 본 연구의 제안방법은 FEM 해석결과와 비슷한 경향을 나타내었다.

사장교의 내풍해석을 통한 인명보호 구조물의 내하능력평가 (Load-carrying Capacities of Safety Structures on Wind-resistant Analyses of Cable-stayed Bridge)

  • 허택녕
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.587-594
    • /
    • 2022
  • In the 2000s, a lot of cable-type grand bridges are being built in consideration of economic aspects such as the reduction of logistics costs and the distribution of traffic volume due to rapid economic development. In addition, because the recently installed grand bridges are designed in an aesthetic form that matches the surrounding environment as well as the original function of the road bridge, and serves as a milestone in an area and is used as an excellent tourism resource, attracting many vehicles and people, there is an urgent need for a safety structure that can ensure the safety of not only vehicles but also people. In order to make cable-stayed bridge safe on wind for additional five safety structures, main girder models with and without safety structures for wind-tunnel experiments was made, and wind tunnel experiments was carried out to measure aerodynamic force coefficients. Also, wind-resistant analyses of 3D cable-stayed bridge were performed on the basis of wind-tunnel experiment results. From the wind tunnel experiments for the aerodynamic force coefficients of main girder with five safety structures and the wind resistant analyses of cable-stayed bridge without safety structure and with safety structure, it was concluded that the best form of wind-resistant safety was shown in the order of mesh, standard, bracing, hollow, and closed type. And wind-resistant safety of cable-stayed bridge with hollow and closed type on design wind speed 68.0m/sec was not secured. Finally, as five safety structures are installed, maximum rate of stress increments was shown in the order of steel main beam, steel floor beam, concrete floor beam and cables.