• 제목/요약/키워드: Main Breaker

검색결과 62건 처리시간 0.162초

화재 예방을 위한 태양광 접속반의 지능형 진단 시스템 (Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention)

  • 안재현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향 (Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines)

  • 이종범;정채균;임광식;강지원
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

단상유도전동기의 돌입전류저감을 위한 제어기 설계 (Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor)

  • 박수강;백형래;이상일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Petri Net 형식론을 이용한 철도차량 주차단기 제어회로 모델링 (MCB ladder diagram modeling for Rolling stock using Petri Net formalism)

  • 최권희;안홍관;김재기;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1897-1902
    • /
    • 2008
  • The computer system is used in many application domains and any system error in these domains may either cause critical loss or threaten environment or human life. Though examples of these domains can be found in many areas, the system, which is used in domains for carrying passengers including rolling stocks in particular, is expected to show satisfactory operation all the time. The relay control logic, which is used in rolling stocks, is complex in hardware and occupies considerably large volume. Nevertheless, it has been used for a long time, to let the system safely operate even in the occurrence of an error in the computer system. However, the relay control logic circuit is so complex that the analysis of proper circuit operation and interlocking tends to be dependent only on the designer's experiences instead of being systematically performed. Especially, the analysis following a change, addition and deletion of a previous circuit according to the requirements from a source of demand is significantly limited. In this paper, the accuracy of relay control logic is verified by the use of properties of Petri Net model. In addition, how main circuit breaker (MCB) control circuit is modeled and analyzed by the design methodology is shown.

  • PDF

가정용 전기기구의 효과적인 뇌서지 보호기법 (Effective Protection Methods of Household Electric Appliances. from Lightning Surges)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구 (A study on the cause Analysis and solution of an overheated NGR of the Main Transformer)

  • 박길수;박수홍
    • 한국전자통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.262-267
    • /
    • 2011
  • 본 연구에서 동부산S/S #3M.Tr 및 부민S/S #1,2M.Tr의 중성선에 설치 사용 중인 NGR 과열원인을 분석하고 해소방안을 제시하여 안정적 전력공급에 이바지하고자한다. 전력계통에 사용 중인 변압기 중성점 접지리액터는 1선지락 고장시 변압기에 유입되는 지락고장전류의 크기를 제한하여 변압기 고장을 감소시키는 역할을 하며 가공절연전선의 용융단선고장방지 일단접지변압기 폭발가능성방지 차단기 차단용량감소 등에 기여하는 설비로 고장발생시 전력계통운용에 막대한 지장을 초래할 수 있다. 따라서 전력계통에 설치 운전 중인 동부산S/S #3M.Tr 중성점 접지리액터 TOP&BOTTOM BRACE부의 온도 상승원인분석과 부민S/S 중성점 접지리액터에 흐르는 과전류로 인한 과열원인 분석을 하였다.

A 3-D Steady-State Analysis of Thermal Behavior in EHV GIS Busbar

  • Lei, Jin;Zhong, Jian-ying;Wu, Shi-jin;Wang, Zhen;Guo, Yu-jing;Qin, Xin-yan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.781-789
    • /
    • 2016
  • Busbar has been used as electric conductor within extra high voltage (EHV) gas insulated switchgear (GIS), which makes EHV GIS higher security, smaller size and lower cost. However, the main fault of GIS is overheating of busbar connection parts, circuit breaker and isolating switch contact parts, which has been already restricting development of GIS to a large extent. In this study, a coupled magneto-flow-thermal analysis is used to investigate the thermal properties of GIS busbar in steady-state. A three-dimensional (3-D) finite element model (FEM) is built to calculate multiphysics fields including electromagnetic field, flow field and thermal field in steady-state. The influences of current on the magnetic flux density, flow velocity and heat distribution has been investigated. Temperature differences of inner wall and outer wall are investigated for busbar tank and conducting rod. Considering the end effect in the busbar, temperature rise difference is compared between end sections and the middle section. In order to obtain better heat dissipation effect, diameters of conductor and tank are optimized based on temperature rise simulation results. Temperature rise tests have been done to validate the 3-D simulation model, which is observed a good correlation with the simulation results. This study provides technical support for optimized structure of the EHV GIS busbar.

소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구 (A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP))

  • 이원강;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.29-34
    • /
    • 2012
  • 본 논문에서는 소방전원 및 소방전원 부족시 용량 보완을 위한 인터록 시스템의 한계점 등을 분석하고 소방전원 보존형 발전기(RFP)의 작동방법 등을 제시하여 화재와 같은 상황에 효율적으로 대응할 수 있는 방법을 제시하는데 있다. 소방전원보존형 발전기에서 일괄제어방식은 발전기에 과부하가 걸리면 소방전원보존용 제어기에서 신호를 발신하여 소방부하는 남겨두고 비상부하용 주차단기를 일괄 차단하고, 발전기가 마지막까지 소방부하에 전원이 공급되도록 한 시스템이다. 순차제어방식은 과부하가 걸리면 소방전원보존용 제어기에서 1차 신호를 발신하여 설정된 비상부하의 1단계 부하를 차단한다. 그리고 지속적인 감시 상태에서 소방부하가 증가하여 발전기가 다시 과부하가 걸리면 제어기에서 2차 신호가 발신하여 비상부하의 2단계 부하를 차단하는 시스템이며 각각의 작동 상태를 표시하는 표시장치를 가진다.

전력설비에서의 SF6 저감기술 동향 및 특성 분석 (Trends and Characteristics in SF6 Emission Reduction Technology of Electrical Equipment)

  • 김예원;김정만;박상혁;이문구
    • 한국기후변화학회지
    • /
    • 제4권3호
    • /
    • pp.269-278
    • /
    • 2013
  • $SF_6$ 가스는 $CO_2$에 비해 배출량은 적지만 GWP는 $CO_2$ 가스의 22,800배1)로 높으며, 최근 $non-CO_2$에 의한 온실가스 규제가 강화됨으로에 따라 온실가스 감축을 고려한 친환경 $SF_6$ 처리 기술 개발이 대두되고 있다. 본 연구에서는 전력설비 내에서 절연체로 사용되는 $SF_6$ 가스의 배출양상에 따른 배출 특성을 분석하고, 그에 따른 $SF_6$ 가스 저감기술을 살펴보았다. 주요 기술로는 사용 중의 유지보수와 폐기단계에 적용될 수 있는 가스의 회수율($85{\rightarrow}99%$)을 재고시키는 기술과 $SF_6$ 가스 제거를 위한 촉매 제조에 관한 기술 및 차단기 내부 점검 시 별도 $SF_6$ 가스 회수 없이 충전된 상태에서 내시경으로 차단기 내부를 점검하여 $SF_6$ 가스를 저감하는 기술이 있으며, 이러한 기술을 통해 대기 중 $SF_6$ 가스 저감이 이루어질 것으로 판단된다.

HIL 기반 LNGC PMS 시뮬레이터의 성능 검증 (HIL based LNGC PMS Simulator's Performance Verification)

  • 이광국;박재문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.219-220
    • /
    • 2016
  • 전력 관리 시스템인 PMS는 선박 통합 제어 시스템에서 중요한 역할을 한다. 본 연구에서는 액화 천연가스선의 PMS를 검증하기 위해서 실시간 HIL 시뮬레이션을 구현한다. 시뮬레이터는 터빈 발전기 디젤발전기, 차단기, 주요 3상 부하로 구성되고, 이들 모델은 MATLAB/Simulink로 구현한다. 더불어 FPGA 기반 제어 콘솔과 메인 스위치보드를 구축하여 선박에 탑재 되어 있는 LNGC PMS 제어 환경을 모사 한다. PMS 기능 검증을 위해 LNGC 내 주요 전력소모원 대비 두 가지 전력 분배 모드를 테스트 케이스로 수행한다. 그 결과 본 연구에서 제안한 시스템은 PMS 시뮬레이터로써 시운전 테스트뿐만 아니라 오류 주입 검증용으로 사용될 것이다.

  • PDF