• Title/Summary/Keyword: Magnification Ratio

Search Result 100, Processing Time 0.029 seconds

Dynamic Interaction Analysis of Low, Medium and Super-high Speed Maglev and Guideways (열차-교량의 동적 상호작용을 고려한 중·저속 및 초고속 자기부상열차와 가이드웨이의 동특성 해석)

  • Min, Dong-Ju;Jung, Myung-Rag;Lee, Jun-Seok;Kim, Lee-Hyeon;Kim, Moon-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • The purpose of this study is to examine the dynamic characteristics of low, medium and high speed Maglev trains and guideways through dynamic interaction analysis. The coupled dynamic equations of motion for a vehicle of 10-dof and the associated guideway girders are developed by superposing vibration modes of the girder itself. The controller used in the UTM-01 Maglev vehicle is adopted to control the air gap between the bogie and guideway in this study. The effect of roughness, the guideway deflection-ratio and vehicle speed on the dynamic response of the maglev vehicle and guideway are then investigated using the 4th Runge-Kutta method. From the numerical simulation, it is found that the air gap increases with an increase of vehicle speed and the roughness condition. In particular, the dynamic magnification factor of the guideway girder is small at low and medium speeds, but the factor is noticeable at super-high speeds.

The excimer laser ablation of PET for micro-mold insert - The control of cross sectional shape using Fourier optics - (마이크로 금형 제작을 위한 PET의 엑시머 레이저 어블레이션 - 퓨리에 광학을 이용한 가공 단면 형상의 제어 -)

  • Shin, Dong-Sik;Lee, Je-Hoon;Seo, Jung;Kim, Do-Hoon
    • Laser Solutions
    • /
    • v.6 no.3
    • /
    • pp.19-28
    • /
    • 2003
  • The manufacturing process for the microfluidic device can include sequential steps such as master fabrication, electroforming, and injection molding. The laser ablation, using masks, has been applied to the fabrication of channels in microfluidic devices. In this research, an excimer laser was used to engrave microscopic channels on the surface of PET (polyethylene terephthalate), which shows a high absorption ratio for an excimer laser beam with a wavelength of 248 m. When 50-${\mu}{\textrm}{m}$-wide rectangular microscopic channels are ablated with a 500 ${\times}$ 500 ${\mu}{\textrm}{m}$ square mask at a magnification ratio of 1/10, ditch-shaped defects were found in both corners. The measurement of laser beam intensity showed that a coherent image in the PET target caused such defects. Analysis based on the Fourier diffraction theory enabled the prediction of the coherent shape at the image surface as well as the diffraction beam shape between the mask and the image surface. It also showed that the diameter of the aperture had a dominant effect. The application of aperture with a diameter of less than 3 mm helped to eliminate such defects in the ablated rectangular microscopic channels on PET without such ditch-shaped defects.

  • PDF

COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES (근관충전방법에 따른 폐쇄효과의 비교)

  • Lee, Dong-Kyoung;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF

Static and Dynamic Analysis of Reinforced Concrete Axisymmetric Shell on the Elastic Foundation -Effect of Steel on the Dynamic Response- (탄성지반상에 놓인 철근 콘크리트 축대칭 쉘의 정적 및 동적 해석(IV) -축대칭 쉘의 동적 응답에 대한 철근의 영향을 중심으로-)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.106-113
    • /
    • 1997
  • Dynamic loading of structures often causes excursions of stresses well into the inelastic range, and the influence of the geometric changes on the dynamic response is also significant in many cases. Therefore, both material and geometric nonlinearity effects should be considered in case that a dynamic load acts on the structure. A structure in a nuclear power plant is a structure of importance which puts emphasis on safety. A nuclear container is a pressure vessel subject to internal pressure and this structure is constructed by a reinforced concrete or a pre-stressed concrete. In this study, the material nonlinearity effect on the dynamic response is formulated by the elasto-viscoplastic model highly corresponding to the real behavior of the material. Also, the geometrically nonlinear behavior is taken into account using a total Lagrangian coordinate system, and the equilibrium equation of motion is numerically solved by a central difference scheme. The constitutive relation of concrete is modeled according to a Drucker-Prager yield criterion in compression. The reinforcing bars are modeled by a smeared layer at the location of reinforcements, and the steel layer model under Von Mises yield criteria is adopted to represent an elastic-plastic behavior. To investigate the dynamic response of a nuclear reinforced concrete containment structure, the steel-ratios of 0, 3, 5 and 10 percent, are considered. The results obtained from the analysis of an example were summarized as follows 1. As the steel-ratio increases, the amplitude and the period of the vertical displacements in apex of dome decreased. The Dynamic Magnification Factor(DMF) was some larger than that of the structure without steel. However, the regular trend was not found in the values of DMF. 2. The dynamic response of the vertical displacement and the radial displacement in the dome-wall junction were shown that the period of displacement in initial step decreased with the steel-ratio increases. Especially, the effect of the steel on the dynamic response of radial displacement disapeared almost. The values of DMF were 1.94, 2.5, 2.62 and 2.66, and the values increased with the steel-ratio. 3. The characteristics of the dynamic response of radial displacement in the mid-wall were similar to that of dome-wall junction. The values of DMF were 1.91, 2.11, 2.13 and 2.18, and the values increased with the steel-ratio. 4. The amplitude and the period of the hoop-stresses in the dome, the dome-wall junction, and the mid-wall were shown the decreased trend with the steel-ratio. The values of DMF were some larger than those of the structure without steel. However, the regular trend was not found in the values of DMF.

  • PDF

EFFECTIVENESS OF CUSTOMIZED MASTER CONE ON APICAL SEALING IN VARIOUS APICAL SIZE OF PREPARED ROOT CANALS (근단부 크기에 따른 customized master cone의 치근단 밀폐효과에 관한 연구)

  • Hong, Hye-Young;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.66-76
    • /
    • 2002
  • The purpose of this study is to evaluate the effectiveness of customized master cone on apical sealing in various apical size of prepared root canals, that is MAF(Master Apical File) and to know at which apical size the apical leakage is to be significantly reduced using customized master cone. 120 extracted single rooted premolars were divided into four groups according to their apical size(MAF), #30, 40, 50 and 60. And then, each group was subdivided into three in accordance with three obturation methods, lateral condensation with standardized master cone, lateral condensation with chloroform-dipped customized master cone, and continuous wave of obturation technique. Resorcinol-formaldehyde resin was used for the microleakage test of this study. Teeth were sectioned horizontally at 1.5mm(Level 1), 2.5mm(Level 2), and 3.5mm(Level 3) from the anatomical root apex using low speed microtome. All sections were examined under $\times$40 magnification with a stereomicroscope, photographed, and then scanned. With the scanned images, resin-infiltrated area presenting the microleakage was calculated using SigmaScan/Image, and the ratio of leakage to the total root canal area of each group was analyzed statistically(one way ANOVA). The results were as follows ; 1. In groups of MAF #30, there was no significant difference of mean leakage ratio among three obturation methods at all three levels. 2. In groups of MAF #40, the group using lateral condensation with customized master cone had the low-est mean leakage ratio at all three levels, but there was no significant difference among three obturation techniques. 3. In groups of MAF #50, the mean leakage ratio of the group using lateral condensation with standard master cone was the highest among those of three obturation techniques at level 1, and this difference was statistically significant(p<0.05). 4 In groups of MAF #60, the groups using lateral condensation with standard master cone had also the highest mean leakage ratio at all levels, but there was no significant difference at level 1 and 2. At level 3, the leakage of the group using lateral condensation with standard master cone was significantly higher than that of the group using continuous wave of obturation(p<0.05). The results of this study suggested that the obturation method using customized master cone or the continuous wave of obturation is more effective for apical sealing than that using standardized master cone when MAF is larger than #50.

INFLUENCE OF HEATED SPREADER ON THE SEALING ABILITY OF LATERAL CONDENSATION (측방가압충전시 Heated Spreader 사용유무가 근관밀폐에 미치는 영향)

  • Chung, Won-Gyun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.222-232
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of heated spreader on the sealing ability of lateral condensation, compared with regular cold spreader. Forty two extracted human teeth with single canal were randomly placed into 3 experimental groups, and four additional teeth were used as positive and negative controls. Each group was prepared with Ni-Ti Profile #40 using step-down technique and obturated with standardized colored gutta-percha cone by standard(cold) lateral condensation technique, warm lateral condensation technique with Endotec and hot spreader soaked in glass bead sterilizer, each with Sealapex sealer. Control groups were not obturated, but prepared. After 2 days in 2% methylene blue, the teeth were invested and made into transparent resin blocks. And then, each block was sectioned horizontally with microtome at 1, 2, 3, 4, 5 mm levels from the apex. The linear extent of dye penetration was examined with stereomicroscope at ${\times}$20 magnification. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using an analysis of variance(ANOVA) and Scheffe test. The results were as follows ; 1. All experimental groups produced the apical microleakage. 2. The mean leakage was 1.57${\pm}$0.76mm for cold spreader group, 0.86${\pm}$0.95mm for Endotec spreader group, and 0.64${\pm}$0.93mm for hot spreader group. The difference between hot spreader group and cold spreader group was statistically significant(p<0.05). 1. At the 1 mm level, the mean ratio of area of gutta-percha was 74.58${\pm}$13.15(%) for cold spreader group, 65.42${\pm}$14.62(%) for Endotec spreader group, and 80.72${\pm}$14.63(%) for hot spreader group. There was statistically significant difference between hot spreader group and Endotec spreader group(p<0.05). 2. At the 2mm level, the mean ratio of area of gutta-percha was 87.86${\pm}$11.22(%) for cold spreader group, 66.55${\pm}$14.02(%) for Endotec spreader group, and 92.93${\pm}$7.24(%) for hot spreader group. There was statistically significant difference between Endotec spreader group and other two spreader groups(p<0.05). 3. At the level 3, 4, 5 mm, there was no statistically significant difference between each group. Within the limits of the results of this experiment, warm lateral condensation technique with hot spreader soaked in a glass bead sterilizer demonstrated favorable apical sealing effect and improved density of gutta-percha mass. Thus, it is thought that this obturation technique is effective for clinical use and beneficial to reduce condensation forces, also economical and easy. Lateral condensation, Heated spreader, canal sealing, Microleakage.

  • PDF

The Optimization of NDT Method for Real Time X-ray Imaging (X선 실시간 영상장치를 이용한 비파괴시험 조건 최적화 연구)

  • Na, Sung-Youb;Choi, Yong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • This study has investigated the optimization of NDT method and the minimum detectable defect size for complex structures such as the solid propellant rocket motor using real time X-ray imaging system. Test specimens were made of steel plates with various defect size, and installed with proper thickness for which solid propellant, rubber, and case converted to the steel equivalent thickness according to the radiographic equivalent theory. As the results, this examination obtained optimum magnification and X-ray energy, dose rate according to steel equivalent thickness, also, obtained the relationship between minimum detectable defect size and the ratio(defect depot/object thickness). Thus, this simulated test is the preliminary procedure before performing NDT for real objects, and is possibly applied for NDT of other complex structures.

  • PDF

Chondrogenic Effect of Transplanted Type I Collagen Scaffold within Subperichondrial Cartilage Defect (연골막하 연골 결손부에 삽입한 제 1형 아교질 지지체의 연골 재생 효과)

  • Lee, Hyuk Gu;Son, Dae Gu;Han, Ki Hwan;Kim, Jun Hyung;Lee, So Young
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.521-528
    • /
    • 2005
  • The purpose of this research is to find out the degree of cartilage regeneration by inserting the atelo-collagen scaffold obtained from dermis of a calf on cartilage defect site. Dissection underneath the perichondrium by the periosteal elevator on both side of ears of six New Zealand white rabbits were made to expose the cartilage, leaving pairs of circular holes 3, 6, 9 mm width with punches. One hole was left for a control, and on the other hole atelo-collagen scaffold of the same size was transplanted. In postoperative 1, 2, 4 weeks, the tissues were dyed. The length of long axis of neocartilage was measured through an optical microscope with a 0.1 mm graduation at original magnification, ${\times}40$. In the first and second week, both group showed no sign of cartilage regeneration. In the fourth week, regeneration on marginal portions was observed on all groups and the average values of length of long axis of neocartilage according to defect size were as follows: In the cases with 3mm defect, it was $0.85{\pm}0.30mm$ in the control group, and $1.85{\pm}0.38mm$ in the graft group; in the cases with 6 mm defect, $1.33{\pm}0.58mm$ in the control group, and $2.25{\pm}0.46mm$ in the graft group; and in the cases with 9 mm defect, $2.33{\pm}0.77mm$ in the control group, and $4.47{\pm}1.39mm$ in the graft group. This means that the collagen scaffold has an influence on the regeneration of neocartilage. But the relative ratio of the length of neocartilage to cartilage defect size was not significant in the statistics.

An effective quality improvement scheme of magnified image using the surface characteristics in image (영상의 곡면 특성을 활용한 효과적인 확대영상의 화질 향상 기법)

  • Jung, Soo-Mok;On, Byung-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.45-54
    • /
    • 2014
  • In this paper, we proposed an effective quality improvement scheme of magnified image using the surface characteristics in image. If the surface in image is estimated as simple convex surface or simple concave surface, the interpolated value can be calculated to have the surface characteristics by using the other method in the proposed scheme. The calculated value becomes the interpolated pixel value inmagnified image. So, themagnified image reflects the surface characteristics of the real image. If the surface is not estimated as simple convex surface or simple concave surface, the interpolated value is calculated more accurately than bilinear interpolation by using the method of the proposed scheme. The PSNR values of the magnified images using the proposed schemes are greater than those of the magnified images using the previous interpolation schemes.

Measurement of Ballooning Gap Size of Irradiated Fuels Using Neutron Radiography Transfer Method and HV Image Filter

  • Sim, Cheul-Muu;Kim, TaeJoo;Oh, Hwa Suk;Kim, Joon Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.212-218
    • /
    • 2013
  • A transfer method of neutron radiography was developed to measure the size of the end plug and a gap of an intact K102L-2, the irradiated fuel of a ballooned K174L-3, a ballooned and ruptured K98L-3. A typical irradiation time of 25 min. was determined to obtain a film density of between 2 and 3 of SR X-ray film with neutrons of $1.5{\times}10^{11}n{\cdot}cm^{-2}$. To validate and calibrate the results, a RISO fuel standard sample, Cd plate and ASTM-BPI/SI were used. An activated latent image formed in the $100{\mu}m$ Dy foil was subsequently transferred in a dark room for more than 8 hours to the SR film which is a maximum of three half-lives. Due to the L/D ratio an unsharpness of $9.82-14{\mu}m$ and a magnification of 1.0003 were given. After digitizing an image of SR film, the ballooning gap of the plug was discernible by an H/V filter of image processing. The gap size of the ballooned element, K174L-3, is equal to or greater than 1.2 mm. The development of a transfer method played a pivotal role in developing high burn-up of Wolsung and PWR nuclear fuel type.