Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

Analysis of Eddy Current Loss on Permanent Magnets of Interior Permanent Magnet Synchronous Motor for Railway Transit (철도차량용 매입형 영구자석 동기전동기의 영구자석 와전류 손실 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Kim, Nam-Po
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2310-2316
    • /
    • 2011
  • In order to apply Interior Permanet Magnet Synchronous Motor(IPMSM) to the propulsion system of the railway transit, 110 (kW) class IPMSMs with high-power density are designed as a concentrated winding model and a distributed winding model in this study. The concentrated winding model designed in this study is 6 poles/9 slots and the distributed winding model is 6 poles/36 slots. In general, the eddy current losses in the permanent magnets of IPMSM are caused by the slot harmonics. The thermal demagnetization of the magnet by the eddy current losses at high rotational speed often becomes one of the major problems in the IPMSM with a concentrated windings especially. A design to reduce eddy current losses in permanent magnets design is important in IPMSM for the railway vehicle propulsion system which requires high-speed operation. Therefore, a method to devide the permanent magnet is proposed to reduce the eddy current losses in permanent magnet in this study. Authors analyze the variation characteristics of the eddy current losses generated in permanent magnet of the concentrated winding model by changing the number of the division of the permanent magnets.

  • PDF

Application of Acoustic Emission Technique for On-Line Monitoring of Quench in Racetrack Superconducting Coil at Cryogenic Environment (음향방출기법을 이용한 극저온 환경하에서 초전도 계자코일의 퀀칭탐지 적용에 관한 연구)

  • Lee, Min-Rae;Gwon, Yeong-Gil;Lee, Jun-Hyeon;Son, Myeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.858-865
    • /
    • 2000
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE)echnique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. In addition, the source location of quench in superconducting magnet was also discussed on the basis of correlation between magnet voltage and AE energy.

A Case of Gastroduodenal Fistula Caused by Ingested Magnetic Foreign Bodies (자석 이물에 의한 위-십이지장 누공 1예)

  • Lee, Won-Hee;Min, Young-Don;Moon, Kyung-Rye
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.84-88
    • /
    • 2008
  • If multiple magnets are ingested, the potential exists for the magnets attracting one another across the gastrointestinal tract and inducing pressure necrosis, perforation, fistula formation, or intestinal obstruction. We report the case of a 12-year-old boy who suffered from a fistulous communication between the lesser curvature of the mid-body of the stomach and the duodenal bulb, caused by 4 ingested magnets (Singing Magnets, China). The patient presented with moderate mental retardation, a one-year history of cyclic vomiting, and abdominal discomfort. We present the findings of simple abdominal radiography, esophagogastroduodenoscopy, computed tomography, and upper gastrointestinal series. An emergency exploratory laparotomy was performed, which revealed a gastroduodenal fistula. Fistula repair and the removal of 4 magnetic toys were subsequently performed. We emphasize that clinicians who care for children should be aware of the hazards of magnetic toy ingestion.

  • PDF

The Coercivity Enhancement of (Nd,Dy)-Fe-B Sintered Magnet by Microstructure Control (미세구조 제어를 통한 (Nd,Dy)-Fe-B 소결자석의 보자력 증가)

  • Kim, Jin-Woo;Kim, Se-Hoon;Kim, Young-Do
    • Journal of Powder Materials
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Sintered Nd-Fe-B magnets are widely used in many fields such as motors, generators, actuators, microwaves and so on due to their excellent magnetic properties. Many researchers have shown that the Nd-rich phase was essentially important for high magnet properties. In this study, we focused on controlling of the Nd-rich phase to enhance magnetic properties by the cyclic sintering process. Nd-Fe-B based sintered magnets were prepared by isothermal sintering and cyclic sintering processes. Magnetic properties and microstructure of the magnets were investigated. The coercivity was enhanced from 21.2 kOe to 23.27 kOe after 10 cycles of the sintering. The Nd-rich phase was effectively penetrated into the grain boundary between the $Nd_2Fe_{14}B$ grains by the cyclic sintering.

Inward Diffusion of Tb Ions and the Magnetic Properties of the Nd-Fe-B Magnets (열처리 조건에 따른 Tb이온의 확산 및 Nd-Fe-B 자석의 자기적 특성)

  • Oh, Seong-Uk;Kim, Dong-Whan;Gong, Gun-Seung;Heo, Young-Woo;Kim, Jeong-Joo;Lee, Joon-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • In this study, the effect of Tb inward diffusion on the magnetic properties of the Nd-Fe-B sintered magnets was studied. After sintering of the magnets, $TbF_3$ slurries were dip-coated on the surface of the samples, then heat-treatment was followed for $TbF_3$ diffusion. The element distribution in the magnets and the diffusion profiles of Tb ions were analyzed by an EPMA (electron probe micro-analyzer). Prolonged heat treatment resulted in a deeper diffusion length of Tb ions. Coercivity of the $1^{st}$ heat-treated sample showed 21.86 kOe, while that of the $1^{st}$, $2^{nd}$ heat-treated and annealed sample revealed 34 kOe.

Development of Localization and Pose Compensation for Mobile Robot using Magnetic Landmarks (마그네틱 랜드마크를 이용한 모바일 로봇의 위치 인식 및 위치 보정 기술의 개발)

  • Kim, Bum-Soo;Choi, Byung-June;You, Won-Suk;Moon, Hyung-Pil;Koo, Ja-Choon;Choi, Hyouk-Ryeol
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.186-196
    • /
    • 2010
  • In this paper, we present a global localization and position error compensation method in a known indoor environment using magnet hall sensors. In previous our researches, it was possible to compensate the pose errors of $x_e$, $y_e$, ${\theta}_e$ correctly on the surface of indoor environment with magnets sets by regularly arrange the magnets sets of identical pattern. To improve the proposed method, new strategy that can realize the global localization by changing arrangement of magnet pole is presented in this paper. Total six patterns of the magnets set form the unique landmarks. Therefore, the virtual map can be built by using the six landmarks randomly. The robots search a pattern of magnets set by rotating, and obtain the current global pose information by comparing the measured neighboring patterns with the map information that is saved in advance. We provide experimental results to show the effectiveness of the proposed method for a differential drive wheeled mobile robot.

Study on the Interaction of Compound Bonded Magnets

  • Chang, Ying;Ma, Nuo;Yu, Xiaojun;Lian, Fazeng;Li, Wei
    • Journal of Magnetics
    • /
    • v.9 no.4
    • /
    • pp.105-108
    • /
    • 2004
  • The attempt for the addition of double-phase nanocomposite $Nd_2Fe_{14}BFe_3B$ powders, respectively, into several $RE_2Fe_{14}B$(RE=Pr, Nd) powders with high magnetic properties was carried out. The powders were compounded and compressed to take shape bonded magnets. By means of investigating the variation of compound magnet $B_r$, the interaction between magnetic powders was revealed. The result shows that not chemical just but physical interaction exists between elements. The compound effect of $Nd_2Fe_{14}BFe_3B$-ferrite bonded magnets was detailed studied. The functional relation was revealed between magnetic properties and ferrite content. That is $Y = 5.42 x^2 -11.34x + 6.62$. The variation of $_iH_c$ temperature coefficient ${\beta}_{iHc}$ with ferrite content was investigated. Following the ferrite content increased, ${\beta}_{iHc}$ and $h_{irr}$ were obviously decreased, compression-resistant strength was enhanced.

Novel Design and Research for a High-retaining-force, Bi-directional, Electromagnetic Valve Actuator with Double-layer Permanent Magnets

  • You, Jiaxin;Zhang, Kun;Zhu, Zhengwei;Liang, Huimin
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • To increase the retaining force, a novel design for a concentric, bi-directional, electromagnetic valve actuator that contains double-layer permanent magnets is presented in this paper. To analyze the retaining-force change caused by the magnets, an equivalent magnetic circuit (EMC) model is established, while the EMC circuit of a double-layer permanent-magnet valve actuator (DLMVA) is also designed. Based on a 3D finite element method (FEM), the calculation model is built for the optimization of the key DLMVA parameters, and the valve-actuator optimization results are adopted for the improvement of the DLMVA design. A prototype actuator is manufactured, and the corresponding test results show that the actuator satisfies the requirements of a high retaining force under a volume limitation; furthermore, the design of the permanent magnets in the DLMVA allow for the attainment of both a high initial output force and a retaining force of more than 100 N.

Effect of Ba Stearate Addition on Magnetic Properties of Ba-system W-type Ferrite Magnets

  • Yamamoto, Hiroshi;Nishio, Hiroaki;Sawayama, Yoshihito
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1165-1166
    • /
    • 2006
  • An experiment was carried out to investigate the effect of Ba Stearate as a reducing agent on the magnetic and physical properties of anisotropic $BaFe_2-W$ type ferrite magnets. It was found that the magnetic properties of $BaO{\cdot}8.5Fe_2O_3$ were improved by adding 0.3 wt% of Ba Stearate, 0.5 wt% of $SiO_2$, and 0.5 wt% of CaO together. The optimum conditions for making magnets were as follows; semisintering condition: $1350^{\circ}C{\times}4.0$ h in nitrogen gas atmosphere, drying condition: $180^{\circ}C{\times}2.0$ h in air, sintering condition: $1160^{\circ}C{\times}1.5$ h in nitrogen gas atmosphere. Magnetic and physical properties of a typical sample were $J_m$ = 0.46 T, $J_r$ = 0.43 T, $H_{cJ}$ = 182.3 kA/m, $H_{cB}$ = 177.2 kA/m, $(BH)_{max}$ = 33.8 kJ/$m^3$, $T_C$ = $495^{\circ}C$ and $K_A$ = $2.65{\times}10^5\;J/m^3$ and $H_A$ = 1332 kA/m.

  • PDF