• 제목/요약/키워드: Magnetostrictive Vibration

검색결과 79건 처리시간 0.025초

Sol-gel 압전체 박막을 이용한 각속도 센서에 대한 연구 (Study on Angular Rate Sensor using Sol-Gel PZT thin film)

  • Lee, S. H.;R. Meada;M. Esashi
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 춘계학술발표강연 및 논문개요집
    • /
    • pp.34-34
    • /
    • 2003
  • Piezoelectric or magnetostrictive materials, known as smart materials, have been researched widely for sensors or actuators in micro system technology. In our research, thick sol-gel lead zirconate titanate(Pb(Zr$\sub$1-x/Ti$\sub$x/)O$_3$) films were fabricated and their characteristics were investigated f3r angular rate sensor applications. The thickness of the PZT films is 1.5${\mu}$m, which is required by a vibration angular rate sensor for a good actuation and sensing. The remnant polarization of the PZT flms is 12.0 ${\mu}$C/$\textrm{cm}^2$. The electromechanical constants of PZT thin film showed the value of susceptance(B) of 4800${\mu}$ s at capacitance of 790pF. The PZT films were applied to the vibration angular rate sensor structure and the vibration of 1.78 ${\mu}$m in amplitude at the resonant frequency of 35.8㎑ was obtained by driving voltage of 5V$\sub$p-p/ of bulk piezoelectric materials with out of phase signal through voltage and inverting amplifier.

  • PDF

축을 따라 전파되는 초음파 모드의 선택적 측정이 가능한 센서 개발 (Development of sensors with mode-selective measuring capability of ultrasonic waves traveling on a cylindrical shaft)

  • 이호철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.336-339
    • /
    • 2007
  • A sensor having capability to measure two different kinds of ultrasonic waves selectively is described. Under the same bias field configuration, this magnetostrictive type sensor can selectively measure longitudinal waves and flexural ones. Since the switching operation of mode selection is made only by changing the polarity of the permanent magnets used to configure the bias field, it will be very useful after the permanent magnet are interchanged with electromagnets. In order to find the optimal operating bias field, finite elements analysis is used and the condition for flexural wave measurements to meet is found. The linearity of the sensor is verified by experiments and the requirements for linearity also are proposed.

  • PDF

SH파 분산특성 변화를 이용한 배관 점진감육 진단 기법 (Gradual pipe wall thinning diagnosis through the variation of dispersion characteristics of SH waves)

  • 조승현;권휴상;안봉영;이승석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.258-259
    • /
    • 2009
  • Pipe wall thinning is one of severe problems on structural safety in nuclear power plants. A guided wave can be a proper tool for the fast evaluation or monitoring. As for gradual wall thinnings, however, low sensitivity caused by the low reflection coefficient limits the use of the guided wave. In this work, instead of the guided wave reflection at the wall thinning, the variation of dispersion characteristics is concerned. SH waves were employed due to several advantages and the magnetostrictive patch transducers were used for the excitation and sensing of the SH waves. The proposed method were verified with some experiments and showed the feasibility as an effective tool for the inspection of gradual wall thinning.

  • PDF

비틀림 유도파를 이용한 배관 축방향 결함 특성 규명 (Characterization of Axial Defects in Pipeline Using Torsional Guided Wave)

  • 김영완;박경조
    • 한국소음진동공학회논문집
    • /
    • 제25권6호
    • /
    • pp.399-405
    • /
    • 2015
  • In this work we use the mode decomposition technique employing chirplet transform, which is able to separate the individual modes from dispersive and multimodal waveform measured with the magnetostrictive sensor. The mode decomposition technique is also used to estimate the time-frequency centers and individual energies of the reflection, which would be used to locate and characterize axial defects. The arrival times of the separated modes are calculated and the axial defect lengths can be evaluated by using the estimated arrival time. Results from an experiment on a carbon steel pipe are presented and it is shown that the accurate and quantitative defect characterization could become enabled using the proposed technique.

탄성 초음파 회절한계 극복을 위한 하이퍼볼릭 탄성 메타물질의 설계와 구현 (Design and realization of hyperbolic elastic metamaterial for ultrasonic sub-wavelength resolution)

  • 오주환;안영관;승홍민;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.743-744
    • /
    • 2014
  • Hyperbolic metamaterials in which waves can only propagate through the radial direction have achieved much attention these days due to their capability of sub-wavelength resolution. In this work, the realization and optimization of hyperbolic elastic metamaterials are mainly studied. To obtain a new hyperbolic elastic metamaterial, a specially-engineered mass-spring system is introduced. Based on the mass-spring system, the hyperbolic elastic metamaterials are proposed and realized. In addition, the sub-wavelength resolution of the proposed hyperbolic elastic metamaterial is verified by ultrasonic elastic wave experiments. For the experiments, specially-designed magnetostrictive patch transducers are developed to realize two sub-wavelength elastic wave sources. Furthermore, the proposed hyperbolic elastic metamaterial is optimized to maximize its operating frequency ranges by the topology optimization method.

  • PDF

대변위-고정밀 위치제어를 위한 자기변형 self-moving cell 선형모터 (Magentostrictive self-moving cell linear motor for displacement control with large force and high resolution)

  • 두재균;김재환;최승복;박홍근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.249-255
    • /
    • 2000
  • The design and test of an magnetostrictive linear motor(MLM) that operates based on self-moving cell concept is presented. The moving cell is composed of Terfenol-D linear actuator and a ring structure, and a cell train is constructed by connecting two cells in series. Since this motor uses the stroke of Terfenol-D actuators and friction force of the cells, it can essentially produce long stroke and large force. The overall performance of the MLM was measured in terms of speed and force. The pushing force is directly related with the friction force. This work is a proof-of-concept stage and investigation is necessary for realistic application.

  • PDF

초음파 가진을 이용한 2-유체 노즐의 효율 향상 (Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • 제27권4호
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

초음파적용 상온연무기의 분무특성에 관한 연구 (A Study on the Spray Characteristics of the Cold-Fog Spray with Ultrasonic Forcing)

  • 송민근;이경렬;손승우;나우정;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.299-302
    • /
    • 2002
  • Characteristics of the twin fluid spray with ultrasonic forcing are examined in order to obtain the high efficiency of cold fog spray of the automatic pest control machine which has been widely used for the equipment cultivation recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive vibrator of ${\pi}type$ with 28 kHz are applied as the ultrasonic transducer. All experiments are made and observed in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving duality method by ultrasonic forced within liquid, and a combined use method with both of the indirect vibration method and the improving quality method. In results, It was clarified that the ultrasonic effects the atomization of spray droplets and its efficiency is about $10{\%}$ and especially much more in the case of the combined use method.

  • PDF

몰드변압기의 소음 원인 분석 (Analysis of Noise Source for Mold Transformer)

  • 최원호;김원철
    • 동력기계공학회지
    • /
    • 제4권4호
    • /
    • pp.59-64
    • /
    • 2000
  • Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

  • PDF