• Title/Summary/Keyword: Magnetorheological Fluid(MR Fluid)

Search Result 108, Processing Time 0.029 seconds

An Optimal Design of Valve-Mode Magnetorheological fluid dampers for Structural Control (구조물 진동제어용 밸브 모드형 자기유변댐퍼의 최적설계 방법)

  • Moon, Seok-Jun;Huh, Young-Chul;Jung, Hyung-Jo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.393-400
    • /
    • 2006
  • One of the most promising semi-active devices proposed for structural control is magnetorheological fluid (MR) dampers. While many researches are making too much of application to structural control, few of papers are considering how to design the MR dampers having good performance. In this paper, the sub-optimal design procedure for MR dampers is presented. This paper shows that an MR damper having the capacity of about 5,000 N is designed according to proposed procedure, as an exmple.

  • PDF

Optimal Design of MR Damper : Analytical Method and Finite Element Method (MR 댐퍼의 최적설계 : 이론적 방법 및 유한요소 방법)

  • Ha, Sung-Hoon;Seong, Min-Sang;Heung, Quoc-Nguyen;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.581-586
    • /
    • 2009
  • This paper presents an optimal design of magnetorheological(MR) damper based on analytical methodology and finite element analysis. The proposed MR damper consists of MR valve and gas chamber. The MR valve is constrained in a specific volume and the optimization problem identifies geometric dimensions of the valve structure that maximize the pressure drop of the MR valve or damping force of the MR damper. In this work, the single-coil annular MR valve structure is considered. After describing the schematic configuration and operating principle of MR valve and damper, a quasi-static model is derived based on Bingham model of MR fluid. The magnetic circuit of the valve and damper is then analyzed by applying the Kirchoff’s law and magnetic flux conservation rule. Based on the quasi-static modeling and the magnetic circuit analysis, the optimization problem of the MR valve and damper is built. The optimal solution of the optimization problem of the MR valve structure constrained in a specific volume is then obtained and compared with the solution obtained from finite element method.

  • PDF

Optimal Design of MR Damper : Analytical Method and Finite Element Method (MR 댐퍼의 최적설계 : 이론적 방법 및 유한요소 방법)

  • Ha, Sung-Hoon;Seong, Min-Sang;Heung, Quoc-Nguyen;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1110-1118
    • /
    • 2009
  • This paper presents an optimal design of magnetorheological(MR) damper based on analytical methodology and finite element analysis. The proposed MR damper consists of MR valve and gas chamber. The MR valve is constrained in a specific volume and the optimization problem identifies geometric dimensions of the valve structure that maximize the pressure drop of the MR valve or damping force of the MR damper. In this work, the single-coil annular MR valve structure is considered. After describing the schematic configuration and operating principle of MR valve and damper, a quasi-static model is derived based on Bingham model of MR fluid. The magnetic circuit of the valve and damper is then analyzed by applying the Kirchoff' s law and magnetic flux conservation rule. Based on the quasi-static modeling and the magnetic circuit analysis, the optimization problem of the MR valve and damper is built. The optimal solution of the optimization problem of the MR valve structure constrained in a specific volume is then obtained and compared with the solution obtained from finite element method.

Experimental Study on Physical Characteristics of MR Fluid along Temperature Conditions (온도조건에 따른 MR 유체의 물리 특성에 대한 실험 연구)

  • Lee, Seok-Hyun;Son, June;Baek, Dae-Sung;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1247-1252
    • /
    • 2014
  • In the present study, sedimentation and shear stress of MR fluid are investigated to physical characteristics of MR fluid along temperature conditions. MR fluid is a suspension of micrometer-sized magnetic particles in a base liquid. Therefore, dispersion of MR fluid is important in the case of the design and optimization of the system using MR fluid. Due to sedimentation characteristics of MR fluid by magnetic particles, the sedimentation and shear stress of commercial MR fluid are investigated at $25^{\circ}C$ and $80^{\circ}C$ temperatures by using a forced convection oven and a viscometer. From experimental results, the sedimentation and shear stress are more affected by the temperatures of $80^{\circ}C$ than $25^{\circ}C$ and the mixing time of 5min than 10min. Shear stress by the applied current increases the shape of a quadratic equation and are lower 6-18% at $80^{\circ}C$ than $25^{\circ}C$.

A Study on the Fabrication of Magnetorheometer (마그네토리오메타 제작에 관한 연구)

  • 김영민;신영재;이응숙;김동우;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.496-500
    • /
    • 2004
  • A new, commercially available polishing process called magnetorheological finishing is used to polish and figure precision optics. To understand and model this process correctly it is important to determine the mechanical properties of the fluid under the influence of the magnetic field. Magnetorheological (MR) fluids are commonly modeled as Bingham fluids, so one of the essential properties to measure is the yield stress. Since MR fluids are inherently anisotropic, the yield stress will depend on the mutual orientation of the magnetic field and the direction of deformation. The relative orientation of the field and deformation in polishing does not coincide with common rheological setups, so a new rheometer has been designed and tested. This new magnetorheometer design has been shown to give correct stresses during calibration experiments using Newtonian fluids with a known viscosity. The measured stress has also been shown to have a magnitude consistent with published finite element approximations for magnetic fluids. The design of the instrument was complicated because of the requirements imposed upon the magnetic field, and the difficulty in satisfying the no slip boundary condition. Our results show the importance of having a homogeneous field in the test region during measurements. The solutions to these problems and discussion of the measurements on nonmagnetic and magnetic fluids are given.

  • PDF

Vibration Control of an Engine Mount Featuring MR Fluid (MR 유체를 이용한 엔진마운트의 진동제어)

  • 이현희;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.213-218
    • /
    • 2001
  • A magnetorheological(MR) engine mount for a passenger vehicle and its vibration control performance is experimentally evaluated. A mixed-mode model for the MR engine is derived by incorporating Herschel-Bulkely model of the MR fluid. After analyzing the field-dependent damping force, a appropriate size of the MR engine mount is manufactured. The field-dependent is displacement transmissibility of the engine mount is evaluated in the frequency domain at various excitation levels. In addition, time-dependant damping force is experimentally investigated by changing the excitation amplitude.

  • PDF

Optimal Design of a Magnetorheological Haptic Gripper Reflecting Grasping Force and Rolling Moment from Telemanipulator (원격조작기의 악력과 회전모멘트를 고려한 MR 햅틱 그리퍼의 최적설계)

  • Nguyen, Quoc-Hung;Oh, Jong-Seok;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.459-467
    • /
    • 2012
  • In this work, the configuration of a haptic gripper featuring magnetorheological(MR) brakes is proposed and an optimal design of the MR brakes for the haptic griper is performed considering the required braking torque, the uncontrollable torque(zero-field friction torque) and mass of the brakes. Several configurations of MR brake is proposed such as disc-type, serpentine-type and hybrid-type. After the configurations of the MR brakes are proposed, braking torque of the brakes is analyzed based on Bingham rheological model of the MR fluid. The zero-field friction torque of the MR brakes is also analyzed. An optimization procedure based on finite element analysis integrated with an optimization toolbox is developed for the MR brakes. The purpose of the optimal design is to find optimal geometric dimensions of the MR brake structure that can produce the required braking torque and minimize the mass of the MR brakes. In addition, the uncontrollable torque of the MR brakes is constrained to be much smaller than the required braking torque. Based on the developed optimization procedure, optimal solution of the proposed MR brakes are achieved and the best MR brake is determined. The working performance of the optimized MR brake is then investigated.

Dynamic Characteristics of Magneto-rheological Fluid Actuator for Micro-motion Control (미세동작제어를 위한 자기유변유체 구동기의 동적 특성)

  • Kim, Pyunghwa;Han, Chulhee;Suresh, Kaluvan;Park, Choon-Yong;Shin, Cheol-Soo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.511-517
    • /
    • 2016
  • This paper presents dynamic characteristics of a new actuator using magneto-rheological(MR) fluid between two electrode type coils. The concept of the actuator is to strengthen the force due to the magnetic field produced by the electrode-coil for MR fluid. The amount and direction of current input to the electrode-coils decide the characteristics of contraction-mode and extension-mode. For achieving the required actuating displacement and actuating force, the yield stress of the MR fluid between two electrode-coils is precisely changed by the input current. In this work, the MR fluid is operated in squeeze mode. The experimental results shown in this paper depict that it can be applied in the micro-level displacement and vibration control system.

Semiactive Neuro-control for Seismically Excited Structure Considering Dynamics of MR Damper (지진하중을 받는 구조물의 MR 유체 감쇠기를 이용한 반능동 신경망제어)

  • 이헌재;정형조;오주원;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.403-410
    • /
    • 2003
  • A new semiactive control strategy for seismic response reduction using a neuro-controller and a magnetorheological (MR) fluid damper is proposed. The proposed control system adopts a clipped algorithm which induces the MR damper to generate approximately the desired force. The improved neuro - controller, which was developed by employing the training algorithm based on a cost function and the sensitivity evaluation algorithm replacing an emulator neural network, produces the desired active control force, and then by using the clipped algorithm the appropriate command voltage is selected in order to cause the MR damper to generate the desired control force. The simulation results show that the proposed semiactive neuro-control algorithm is quite effective to reduce seismic responses. In addition, the semi-active control system using MR fluid dampers has many attractive features, such as the bounded-input, bounded-output stability and small energy requirements. The results of this investigation, therefore, indicate that the proposed semi-active neuro-control strategy using MR fluid dampers could be effectively used for control of seismically excited structures.

  • PDF