• 제목/요약/키워드: Magnetizing inductance

검색결과 83건 처리시간 0.021초

태양광 발전 시스템을 위한 LLC 직렬공진컨버터 적용 무접점 전원장치 (A Contact-less Power Supply using LLC resonant converter for Photovoltaic Power Generation System)

  • 이현관;이기식;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.347-350
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer. Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without any auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transfonner are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

  • PDF

Design Considerations of Resonant Network and Transformer Magnetics for High Frequency LLC Resonant Converter

  • Park, Hwa-Pyeong;Ryu, Younggon;Han, Ki Jin;Jung, Jee-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.383-392
    • /
    • 2016
  • This paper proposes the design considerations of resonant network and transformer magnetics for 500 kHz high switching frequency LLC resonant converter. The high power density can be effectively achieved by adopting high switching frequency which allows small size passive components in the converter. The design methodology of magnetizing inductance is derived for zero voltage switching (ZVS) condition, and the design methodology of the transformer and output capacitance is derived to achieve high power density at high operating frequency. Moreover, the structure of transformer is analyzed to obtain the proper inductance value for high switching operation. To verify the proposed design methodology, simulation and experimental results will be presented including temperature of passive and active components, and power conversion efficiency to evaluate dominant power loss. In addition, the validity of magnetics design will be evaluated with operating waveforms of the prototype converter.

확장영역 전기자동차 응용을 위한 유도전동기의 고효율 운전 특성 (The High Efficiency Operating Characteristics of the Induction Motor for Extended Range Electric Vehicle Applications)

  • 유두영;손진근;전희종;최욱돈
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.273-279
    • /
    • 2016
  • In this paper, a high-performance control of the induction motor for electric car was implemented to escape dependence of the rare earth magnet. Proposed high-efficiency control algorithm is a Direct Rotor Field-Oriented Control method that is insensitive to the fluctuation of motor parameters. In the DRFOC method, we need to compensate fluctuation of stator transient inductance and magnetizing inductance caused by the magnetic saturation of induction motor in high-speed area. This paper proposes Back-EMF Observer based on stator current estimator of Luenberger style. Motor control system applied the Voltage Feedback Flux Weakening Control method for high-speed operation. The proposed algorithm was verified through tests by the power train of Extended Range Electric Vehicle consists of induction motor and differential gear.

Adaptive Link Voltage Variation (ALVV) Control for High Efficiency in High Power Density Adapter

  • Kim, Bong-Chul;Lee, Byoung-Hee;Park, Ki-Bum;Kim, Chong-Eun;Ryu, Byoung-Woo;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.508-510
    • /
    • 2008
  • In designing a LLC resonant converter, the ratio of magnetizing inductance ($L_M$) to resonant inductance ($L_R$), the inductor ratio (K) is usually considered. In high power density adapter, both adapter size and efficiency are important factors. Considering the size of adapter, high K design can be more attractive. But, wide frequency variation of high K design results in design difficulty of magnetic elements and decrease in efficiency. To solve these drawbacks, an adaptive link voltage variation (ALVV) control is proposed. With the proposed control method, the LLC resonant converter can be operated at the resonant frequency despite the output voltage variation. The control strategy and schematics are presented, and verified experimentally.

  • PDF

상태방정식에 의한 자기여자 유도발전기의 과도전압특성 (Transient Voltage Characteristic of Self-excited Induction Generator by State Equation)

  • 김도진;좌종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.882-884
    • /
    • 2002
  • The transient voltage characteristics of capacitor self-exited induction generator are analyzed by the state equation which is obtained from the d-q axis equivalent circuit of stationary reference frame and torque equation. The d-q equivalent circuit is composed using the condition of stationary reference frame. The mutual inductance is only considered as a function of magnetizing current in the equivalent circuit. The characteristics are analyzed and discussed by the backward Euler method for various load conditions under specified initial conditions and input.

  • PDF

블록 적응알고리즘을 이용한 유도전동기 적응벡터제어 (Adaptive Vector Control for Induction Motor Using Block Adaptive Algorithm)

  • 박영산;조성훈;배철오;이성근;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.324-329
    • /
    • 1999
  • This paper proposes new torque control of an induction motor, which is robust against time verying parameters. The control is based on adaptive vector control with serial block adaptive algorithm. Motor parameters used to estimates slip frequency and torque. Frequency mismatch in the control system detrimentally affects slip frequency estimation and torque response. In order to compensate for degradation of the responses an adaptive identifier for the magnetizing inductance and the secondary time constand is introduced. adaptive vector control system consisted of two subsystems, a vector control system realized on synchronous frame and a parameter identification system on stationary frame. the effectiveness of the proposed method was verified by some digital simulations.

  • PDF

고출력 응용을 위한 영구자석 매입형 동기 릴럭턴스 전동기의 특성해석 (Characteristic Analysis of Permanent Magnet Assisted Synchronous Reluctance Motor for High Power Application)

  • 장영진;김기복;이중호;김상길;신흥교
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권10호
    • /
    • pp.585-596
    • /
    • 2004
  • In this paper, finite element analysis for a PMASynRM is presented and the characteristic analysis of inductance and torque is performed under the effect of saturation. The focus of this paper is characteristic analysis of d and q-axis inductances and torque according to magnetizing quantity of interior permanent magnet for PMASynRM. The d and q-axis current component ratios, load angles of a PMASynRM are investigated quantitatively on the basis of the proposed analysis method and the experimental test. Comparisons are given with output characteristic curves of normal SynRM and those according to the load in PMASynRM, respectively And it is confirmed that the proposed model results in high output power performance.

변류기 2차전류의 포화 여부 판단 알고리즘 (An Algorithm for Detecting CT Saturation)

  • 강용철;옥승훈;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.275-278
    • /
    • 2001
  • This paper presents an algorithm for detecting current transformer (CT) saturation. At the instants of beginning (or end) of saturation, as a magnetizing inductance of the core is changed significantly, the shapes of the secondary current are also changed significantly though secondary currents are continuous the instants. At the instants, the second-order of third-order difference of the secondary current has big values. Thus, the third difference of the current is used to detect the beginning/end of CT saturation in this paper. If the magnitude of third-order difference of the secondary current is larger than a threshold value, the CT begins of ends saturation at the instants. The proposed detection method is unaffected by the amount of residual flux. The results of various tests with residual flux from -80% to +80% indicate satisfactory performance of the method.

  • PDF

변압기 영향을 포함한 고정주파수 LCL형 DC-DC 컨버터 해석 (Analysis of A Fixed Frequency LCL-type DC-DC Converter Including the Effect of High-Frequency Transformer)

  • 박상은;차한주
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.81-87
    • /
    • 2016
  • An LCL-type Isolated dc-dc converter operating for constant output voltage is analyzed, including the effect of a high frequency transformer using ac complex circuit approximation. Its solution is derived and is used to obtain the characteristics of the proposed converter. The analyses show through converter modeling, phasor diagram and gain comparison that inclusion of a high frequency transformer results in introduction of magnetizing inductance and leakage inductances at conventional LCL dc-dc converter with ideal transformer. The theoretical and simulation results are presented in case of the wide variations in input voltage and load current in detail. Analysis and simulation results observed that introduction of a transformer in the dc-dc converter had considerable effect on the performance, especially in the case of low output voltage and large load.

파라미터 적응동정에 의한 유도전동기의 중.저속운정 과도특성개선 (Improvement of Transient Characteristics at middle and low Speed Region of induction Motor using Adaptive identification)

  • 이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권6호
    • /
    • pp.738-747
    • /
    • 1999
  • Vector controlled induction motor have been widely used in high performance applications. How-ever the performance is sensitive to the variations of motor parameters especially the rotor time constant which varies with the temperature and the saturation of the magnetizing inductance. In this paper the authors propose new identifying method for time-varying parameters of an induction motor which is based on adaptive vector control with serial block algorithm. Vector con-trol system realized on synchronous frame and parameter identification system realized on sta-tionary frame are not easily affected by the vector control frame. Parameter mismatch in the control system results in heavy transient variation in speed and torque response. In order to compensate degradation of the responses at the middle and low speed region adaptive identifier is introduced. To verify the feasibility of this technique compute simu-lations carried out.

  • PDF