• Title/Summary/Keyword: Magnetic-less

Search Result 760, Processing Time 0.025 seconds

Evaluation of DC Brush-less Motors Using Powder Magnetic Cores

  • Mori, Katsuhiko;Nakayama, Ryoji;Kanagawa, Kinji
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1169-1170
    • /
    • 2006
  • We made a high-speed motor and a DC brush-less motor for factory automation (FA) to investigate applicability of powder magnetic core to motor application, and compared those performances with the similar motors having conventional electro magnetic steel core. Permeability and saturated magnetization of powder magnetic core are less than those of elect romagnetic steel core, however output performances of each core motor are almost the same. The FA motor with powder magnetic core using three-dimensional magnetic circuit showed higher torque than the same volume motor with electromag netic steel core.

  • PDF

The characteristic analysis of contact-less Power supply by 3D finite element method

  • Park, Han-Seok;Cho, Yun-Hyun;Jung, Hong-Sub;Woo, Kyung-il;Kim, Kyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.145-151
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of contact-less power supply by the 3D finite element method with a variation of the secondary core position. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. The magnetic coupling coefficients are obtained also. The power factors are obtained by simulation for the magnetic coupling coefficients and compared.

The influence of magnetic field on the alignment of steel fiber in fresh cementitious composites

  • Li, Hui;Li, Lu;Li, Lin;Zhou, Jian;Mu, Ru;Xu, Mingfeng
    • Computers and Concrete
    • /
    • v.30 no.5
    • /
    • pp.323-337
    • /
    • 2022
  • This paper proposes a numerical model to simulate the rotational behavior of steel fiber in fresh cement-based materials in the presence of a magnetic field. The results indicate that as the aspect ratio of fiber increases, the required minimum magnetic field intensity to make fiber rotate in viscous fluid increases. The optimal magnetic field intensity is 0.03 T for aligning steel fiber in fresh cement-based materials to ensure that the applying time of the magnetic field can be conducted concurrently with the vibrating process to increase the aligning efficiency. The orientation factor of steel fiber in cement mortar can exceed 0.85 after aligning by 0.03 T of the uniform magnetic field. When the initial angle of the fiber to the magnetic field direction is less than 10°, the magnetic field less than 0.03 T cannot make the fiber overcome the yield stress of fluid to rotate. The coarse aggregate in steel fiber-reinforced concrete is detrimental to the rotation and alignment of the steel fiber. But the orientation factor of ASFRC under the 0.03T of the magnetic field can also exceed 0.8, while the orientation factor of SFRC without magnetic field application is around 0.6.

A Simple a.c. Magnetic Susceptometer Using self-inductance Measurement of a Single Coil Mounted on a Cryostat Cold Head

  • Dho, Joong-Hoe
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.177-181
    • /
    • 2008
  • A very simple a.c. magnetic susceptometer for use in a helium closed cycle cryostat is reported in this paper. This simple setup has only a single bobbin-less copper coil, instead of the primary coil and two secondary coils typically used in mutual-inductance types. The single bobbin-less copper coil is directly mounted on the cryostat cold head. A sample is attached on the inside wall of the copper coil using a thermal contact material and its a.c. magnetic susceptibility is obtained from the measurement of the self-inductance of the sample coil using an LCR meter or an impedance analyzer. Experimental details are described and illustrative measurements on magnetic and superconducting materials as a function of temperature are included. The performances and limitations of this simple a.c. magnetic suceptometer are also discussed.

Paratesticular Liposarcoma with Atypical Image Findings: a Case Report

  • An, Jihae;Kim, Keum Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.66-70
    • /
    • 2022
  • Paratesticular liposarcoma is a very rare tumor that is typically reported as isolated cases of or as components of larger studies of liposarcomas. Image findings are similar to those of other anatomic sites, but in less-common sites, their appearance may be less familiar, and they may be mistaken for other pathologies. In addition, atypical image findings of liposarcoma make diagnosis more difficult. Herein, we report on the case of a 45-year-old male patient who presented with a painless, palpable mass in the right scrotum. The patient was diagnosed with paratesticular liposarcoma by excisional biopsy.

Fabrication and Characteristics of Superconducting Magnetometer

  • Lee, Sang-Heon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.70-72
    • /
    • 2005
  • The relation between electrical properties of YBaCuO ceramic superconductor and externally applied magnetic field was studied. Electrical characteristics of the superconductor with trapped magnetic fluxes are extremely sensitive to the external magnetic field and show the different responses which depend on the direction of the magnetic field. Considering these properties of the superconductor with trapped magnetic fluxes, a magnetic sensor is fabricated. This sensor is able to detect simultaneously both the intensity and the direction of the magnetic field. The sensitivity of the sensor is less than 10$^{-4} T.

HOW MUCH DOES A MAGNETIC FLUX TUBE EMERGE INTO THE SOLAR ATMOSPHERE?

  • Magara, Tetsuya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.84.2-84.2
    • /
    • 2012
  • We studied the controlling parameters of flux emergence with a focus on the relation between the configuration of coronal magnetic field and the pre-emeged state of subsurface magnetic field. We performed a series of magnetohydrodynamic simulations (dynamic model) and find an interesting result on the twist of coronal magnetic field, that is, the coronal magnetic field formed via flux emergence actually contains less amount of twist (relative magnetic helicity normalized by magnetic flux) than what is expected in kinematic models for global-scale solar eruptions. Based on this result, we propose another possible mechanism for producing these global-scale solar eruptions.

  • PDF

Dynamic Magnetic Field Measurement in the Air Gap of Magnetic Bearings Based on FBG-GMM Sensor

  • Jiayi, Liu;Zude, Zhou;Guoping, Ding;Huaqiang, Wang
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.575-585
    • /
    • 2015
  • Magnetic field in magnetic bearings is the physical medium to realize magnetic levitation, the distribution of the magnetic field determines the operating performance of magnetic bearings. In this paper, a thin-slice Fiber Bragg Grating-Giant Magnetostrictive Material magnetic sensor used for the air gap of magnetic bearings was proposed and tested in the condition of dynamic magnetic field. The static property of the sensor was calibrated and a polynomial curve was fitted to describe the performance of the sensor. Measurement of dynamic magnetic field with different frequencies in magnetic bearings was implemented. Comparing with the finite element simulations, the results showed the DC component of the magnetic field was detected by the sensor and error was less than 5.87%.

The magnetic properties of the systems of the ultra-fine particles

  • Perov, N.S;Sudarikova, N.Yu.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.17-17
    • /
    • 2002
  • The magnetic effects connected to finite-size of the particles become dominant at transition of particles in region several nanometers and less [1]. At reduction of atom numbers in magnetic cluster (tens or hundreds atoms), along the classical features, essential appear the quantum phenomena resulting in spin transformation of magnetic structure, both with reduction of the size and at applying of an external magnetic field. (omitted)

  • PDF

3-D Magnetostatic Field Analysis Using Boundary Element Method (경계요소법을 이용한 3차원 정자장 해석)

  • 전기억;고창섭;정현교;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1211-1217
    • /
    • 1991
  • A three dimensional magnetostatic probodm is analyzed using the boundary element method and the magnetic scalar potential are employed in order to reduce the size of system matrix. Although the total magnetic scalar potential gives very accurate solutions at inner and outer regions of magnetic materal, the method has limitation on application because the magnetic scalar potential due to applied magnetic field sources is hard to be obtained. The reduced magnetic scalar potential gives more or less inaccurate solutions inside the magnetic material but very accurate solutions outside. Hence it can be concluded that the reduced magnetic scalar potential is very useful when the magnetic fields of outside of magnetic fields of outside of magnetic material are interested. It is also shown, from the numerical example, that the linear shape function gives more efficient solutions than the constant shape functions.

  • PDF