• Title/Summary/Keyword: Magnetic transducer

Search Result 82, Processing Time 0.023 seconds

Under Water Sonar Transducer Using Terfenol-D Magnetostrictive Material

  • Son, Derac;Cho, Yuk
    • Journal of Magnetics
    • /
    • v.4 no.3
    • /
    • pp.98-101
    • /
    • 1999
  • In this work we htave constructed an under water sonar transducer using Terfenol-D rod employing open magnetic circuit. Normally Sonar transducer using Terfenol-D was designed under closed magnetic flux return path, and permanent magnet for dc bias marnetic field, but high magnetic field should be applied to the transducer coil for high sound power and it brings temperature increase inside of the transducer. To improve this heat dissipation problem, we have designed an open magnetic circuit type transducer and we can get 200 dB (re. 1 Pa @ 1m) sound power for the input power of 650 VA.

  • PDF

Study on the Magnetic Field Measurement Using the Ultrasonic Transducer (초음파진동자를 이용한 자계측정방법 연구)

  • 손은영;류주현;윤광희;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.350-355
    • /
    • 1997
  • A new magnetic field measuring system with induced coil is reported. This system consists of air-cared coil that is forced by the ultrasonic transducer. Induction voltage of coil is proportional to the DC magnetic field and the driving frequency of ultrasonic transducer by the principle of Faraday's law. The experimental measuring system is setup, and the possibility of a new magnetic field sensors is confirmed.

  • PDF

Program Development for the Underwater-Acoustic Characteristic Analysis of Magnetostrictive Tonpilz Transducer (자왜 Tonpilz 변환기의 음향특성 해석 프로그램 개발)

  • Jung, E.M.;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.705-710
    • /
    • 2002
  • Magnetostrictive materials are used low frequency sonar transmitter instead of piezoelectric materials. But it is difficult to analyze due to the nonlinearity and hysteresis of magnetostrictive materials. This paper deals with the program development for the finite element modeling of magnetostrictive tonpilz transducers and for analyzing their acoustic characteristics. To take into account the nonlinearity of magnetostrictive materials, the magnetic field calculation is separated form the displacement calculation, and a curve fitting is adopted for the nonlinear behavior of the magnetic and mechanical strain fields. At first, the magnetic field is obtained by using a commercial FEM software and the displacement of the transducer is calculated by plugging the obtained magnetic field into forcing term. To verity the accuracy of the developed program, a comparison is made with a commercial code, ATILA.

  • PDF

Magnetic Property Effects of the Strip on Transducer Sensitivity in a Magnetostrictive Strip Type Guided Wave Transducer (자왜 스트립 도파변환기에서 스트립의 자기적 특성이 변환기 감도에 미치는 영향)

  • Kim, Sung-Joon;Choi, Myoung-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.205-210
    • /
    • 2008
  • Magnetic hysteresis loops of a nickel strip and a Fe-Co alloy strip, which have been used in magnetostrictive strip type guided wave transducers for long range ultrasonic testing of pipelines, were measured and then magnetic property effects of a strip on transducer sensitivity were analyzed. The sensitivity of an optimized Fe-Co strip transducer was superior to that of the nickel strip transducer by a factor of about 30. It was shown that this was mainly attributed to the differences in remanence magnetization and coercivity of the two magnetostrictive materials.

A High-sensitivity Passive Magnetic Transducer Based on PZT Plates and a Fe-Ni Fork Substrate

  • Li, Ping;Wen, Yumei;Jia, Chaobo;Li, Xinshen
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.271-275
    • /
    • 2011
  • This paper proposes a magnetoelectric (ME) composite transducer structure consisting of a magnetostrictive H-type Fe-Ni fork substrate and piezoelectric PZT plates. The fork composite structure has a higher ME voltage coefficient compared to other ME composite structures due to the higher quality (Q) factor. The ME sensitivity of the fork structure reaches 12 V/Oe (i.e., 150 V/cm Oe). The fork composite with two PZT plates electrically connected in series exhibits over 5 times higher ME voltage coefficient than the output of the rectangle structure in the same size. The experiment shows the composite of a Fe-Ni fork substrate and PZT plates has a significantly enhanced ME voltage coefficient and a higher ME sensitivity relative to the prior sandwiched composite laminates. By the use of a lock-in amplifier with 10 nV resolution, this transducer can detect a weak magnetic field of less than $10^{-12}$ T. This transducer can also be designed for a magnetoelectric energy harvester due to its passive high-efficiency ME energy conversion.

Performance of Built-in Capacitance Type Transducer of a Magnetic Bearing System (캐패시턴스형 센서가 내장된 자기베어링 시스템의 작동성능에 관한 연구)

  • 장인배;한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2082-2088
    • /
    • 1995
  • In this paper, we designed and fabricated the magnetic bearings and built-in type cylindrical capacitive transducers for improving the vibration characteristics of rotating shaft. The eddy current and magnetic field from the electromagnet of the bearing don't affect the measuring signal of the capacitive type transducers so that it is possible to locate the capacitive sensor plates around the magnetic bearing poles and can improve the spillover problem which is induced by the noncollocation of the sensors and actuators. According to the sensitivity calibration schemes using a X-Y table, the cylindrical capacitive transducers have a good linearities in the .+-.70.mu.m range from the geometric center of the sensor plates. The measured results also show high displacement sensitivities of the sensors. According to the performance test of the magnetic bearing which is controlled by the analog PD controllers, we found that the built-in capacitive transducer system successfully measures the journal displacement in the magnetic field and therefore the magnetic bearing system supports the rotating shaft up to 12,000 rpm.

Development of a new concept magnetostrictive transducer for damage detection of plate structures (평판 상의 결함진단을 위한 신개념 자기변형 트랜스듀서의 개발)

  • Lee, Hyun-Su;Lee, Ho-Cheol;Lee, Ju-Seung;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.566-568
    • /
    • 2008
  • An E-OPMT(Electronically-controllable OPMT) was developed as an alternative of OPMT which could adjust the direction of the generated guided waves in a plate manually. The key idea of controlling the wave direction electronically is based on a few sets of axisymmetric figure-of-eight coils and the magnet which is located for making static omni-directionally biasing magnetic field over the patch. However, in order to explain wave phenomenon generated by this transducer, a new approach is required because there are various combinations between static biasing magnetic field and dynamic actuating magnetic field on the patch, not similar to OPMT. In this paper, the experiments were performed to understand characteristics of E-OPMT and the new theoretical analysis was set up for explaining the result.

  • PDF

Active Vibration Control Method Using Frequency Controllable Piezoelectric Transducer (주파수가변 압전 트랜스듀서를 이용한 능동제진법)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol;Kang, Sung-Hak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1E
    • /
    • pp.27-32
    • /
    • 2007
  • Hydraulic actuator and electro-magnetic liner actuator have been used as typical active vibration control methods. However these methods have many kinds of disadvantages such as causing space limit, difficult maintenance, complicate structures, etc. The purpose of this paper was to study on the possibility of active vibration control using piezoelectric transducer. Piezoelectric transducer generated a vibration and GIC (General Impedance Converter) amplifier was adopted to give adjustable vibration signal to transducer and high amplitude of vibration. Resonance frequency of piezoelectric transducer was controlled by GIC amplifier and higher amplitude of vibration was achieved. Finally active vibration control using piezoelectric transducer was performed.

Effect of Biasing Magnetic Fields on the Patch-type Magnetostrictive Transducers (패치형 자왜 초음파 변환기 성능에 대한 바이어스 자기장의 영향)

  • Lee, Ho-Cheol;Kim, Hee-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1177-1183
    • /
    • 2009
  • The effects of biasing magnetic fields on the performances of magnetostrictive ultrasonic transducers are investigated. The transducers are patch-type ones which are used for SHM of plate structures. Various kinds of configurations of biasing magnets are covered experimentally. It is experimentally verified that how the biasing magnetic field deploys is the most significant factors on maximizing the transducer output. From the magnetostriction curve of nickel, it is concluded qualitatively that it is not the absolute values of biasing magnetic field but the slope of magnetostriction curve to be taken account of.