• 제목/요약/키워드: Magnetic system

검색결과 4,624건 처리시간 0.036초

Robust Electric Compass to Dynamic Magnetic Field Interference

  • Ko, Jae-Pyung;Kim, Yang-Hwan;Kang, Woong-Ki;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1814-1819
    • /
    • 2004
  • The purpose of this research is to improve the reliability of automobile navigation system that utilizes the magnetic compass for localization. On account of its sensitiveness against the dynamic external interference of the magnetic field, the electronic compass itself is not accurate enough to be used for the localization compared to the gyro-compass. To overcome this shortcoming, in this research, a robust electronic compass is designed by using two magnetic compasses to cancel out the dynamic interferences efficiently. That is, a dual compass predictive calibration algorithm against irregular external interference of magnetic field is newly proposed and implemented in this paper. When the dynamic interference can be eliminated from the electronic compass, it becomes much accurate than the gyro-based system that suffers from the accumulative drift error. The reliability and performance of the designed system have been verified through the real driving experiments.

  • PDF

동적간섭자기장에 강인한 전자컴파스 (Robust Electric Compass to Dynamic Magnetic Field Interference)

  • 고재평;강웅기;김양환;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제11권1호
    • /
    • pp.27-33
    • /
    • 2005
  • The purpose of this research is to improve the reliability of automobile navigation system that utilizes the magnetic compass for localization. On account of its sensitiveness against the dynamic external interference of the magnetic field, the electronic compass itself is not accurate enough to be used for the localization compared to the gyro-compass. To overcome this shortcoming, in this research, a robust electronic compass is designed by using two magnetic compasses to cancel out the dynamic interences efficiently. That is, a dual compass predictive calibration algorithm against irregular external interference of magnetic field is newly proposed and implemented in this paper. When the dynamic interference can be eliminated from the electronic compass, it becomes much accurate than the gyro-based system that suffers from the accumulative drift error. The reliability and performance of the designed system have been verified through the real driving experiments.

HIGH QUALITY $^1$H SPECTROSCOPY ON 3.0T MRI

  • Kim, Tae-Yong;Kim, S. Choi;Lee, Heung-Kyu;Park, Jeong-Il;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo;Shinn, Kyung-Sub
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.172-173
    • /
    • 1999
  • PDF

HIGH RESOLUTION IMAGING IN 37 MRI SYSTEM

  • Park, Jeong-Il;Choi, Kim-S.;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo;Shin, Kyung-Sub;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.423-424
    • /
    • 1999
  • PDF

외란을 받는 자기베어링 주축계의 강건제어 (Robust Control of Disturbed Magnetic Bearing Rotor Systems)

  • 강호식;송오섭
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.40-46
    • /
    • 2004
  • Magnetic bearing has been adopted to support a rotor by electromagnetic force without mechanical contact and lubrication process. The recent growth of magnetic bearing applications in many industrial fields requires more accurate design of bearing-rotor system. Due to external forces and uncertainties of magnetic bearing system the actual performance and stability my be worse than it is designed. This paper describes the governing equations of rotor magnetic bearing systems and/or the designing of robust controller via standard $H_{\infty}$ control problem. The system stability and response characteristics are studied by simulations and verified with experimental results.

자기 부상 방식 구동원리를 이용한 다자유도 정밀 위치 시스템의 최적 설계, 모델링 및 제어에 관한 연구 (A Study on the Optimal Design, Modeling and Control of the Multi d.o.f Precision Positioning System Using Magnetic Levitation Actuating Principle)

  • 정광석;백윤수
    • 대한기계학회논문집A
    • /
    • 제25권5호
    • /
    • pp.779-787
    • /
    • 2001
  • The multi degree of freedom system using magnetic levitation has been implemented successfully. Differently from another noncontact systems, the developed system was focused on the maximization of the system stiffness under the constraint of a limited input. The variation of a relative adopting point between the magnetic pair, its location on the fixed base, and the selection of optimal specifications for the main active magnetic elements give us another chance to realize the increased robustness against external disturbances with the less control inputs. In this paper, the overall development procedures are given including the optimal design, the dynamic modeling, the various control tests, and the main issues to be solved.

낙뢰에 의하여 발생되는 자계파형측정 시스템의 구성 (Construction of the Measuring System for Magnetic Field Waveform Associated with Lightning Return Strokes.)

  • 이복희;하봉철;길경석;백용현;이영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1658-1660
    • /
    • 1994
  • This paper describes the measurement system of the magnetic field waveforms generated by lightning return strokes. The frequency bandwidth of magnetic field measurement system is from 270[Hz] to about 2.3 [MHz]. As the application experiment, the magnetic field generated by simple impulse and oscillating impulse currents, which are measured by a current transformer (Tek. AM503), is observed by the trial magnetic field measurement system. The obtained results are agreement with each other. A typical magnetic field waveform associated with lightning return strokes was recorded and presented.

  • PDF

전자기력을 이용한 3 자유도 정밀 위치결정기구에 관한 연구 (A Study on Three Degree-of-Freedom Fine Positioning Device Based on Electromagnetic Force)

  • 이기하;최기봉;박기환;김수현;곽윤근
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.199-207
    • /
    • 1998
  • This paper presents the design and the control of three degree-of-freedom(DOF) fine positioning device based on an electro-magnetic force. The device is designed by use of a magnetic circuit theory and it is capable of fine motion due to the electro-magnetic force. The device consists of permanent magnets, yokes and coils. The magnetic fluxes generated from the permanent magnets constitute magnetic paths through steel, whereas the coils are arranged into the gap between two surfaces of the yokes. Therefore, by supplying current to the coils, the coils are capable of some motions due to Lorentz forces. For the optimal design of the actuating system, the system parameters are defined and investigated under the given constraints. From the system modeling in small displacement, three decoupled equations of motion are obtained. To get better performance of the system, a PID controller is implemented. Experimental results are presented in terms of time response and accuracy.

  • PDF

자성유체 내에서 비자성체의 수동적 부양 조건 (The requirements of passive levitation for nonmagnetic body in magnetic fluid)

  • 전상현;남윤주;박명관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.974-978
    • /
    • 2007
  • In this paper, the requirements of passive levitation for nonmagnetic body in magnetic fluid are investigated. The passive levitation system includes the electromagnetic system composed of two hollow solenoids, the magnetic fluid and the nonmagnetic body made of aluminum. The hollow solenoids generate nonuniform magnetic fields, leading to the gradient of the magnetic field in magnetic fluid. Hence, the resultant magnetic body force in magnetic fluid is used to levitate the nonmagnetic body in the opposite direction of the gravitation. The levitation conditions according to applied current and the mass of the nonmagnetic body are obtained analytically.

  • PDF

실온 자기냉동의 최근 연구개발 동향 (Recent R&D Trend in Magnetic Refrigeration at Room Temperature)

  • 이종석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.613-618
    • /
    • 2006
  • The 1st International Conference on Magnetic Refrigeration at Room Temperature was held at Montreux, Switzerland during September 27-30, 2005. The conference was the first of its kind to bring together about 140 scientists and engineers interested in magnetic refrigeration in one place. The magnetocaloric effect was discovered in 1881, however, magnetic refrigeration at room temperature was demonstrated to be viable in 1997 Since then, R&D efforts toward magnetic refrigeration have been on the rise around the world, in both areas of systems and materials. The conference reflected the recent R&D trend in magnetic refrigeration at room temperature, which includes the use of permanent magnet instead of superconductor magnet, switch from reciprocating to rotary magnetic refrigeration system, development of magnetic materials based on transition metal elements besides rare earth materials such as gadolinium(Gd).

  • PDF