• 제목/요약/키워드: Magnetic resonance(MR), contrast enhancement

검색결과 71건 처리시간 0.02초

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

The Characteristics of Liver Enhancement Pattern using a New Macromolecular MR Contrast Agent in VX2 Tumor Model of Rabbits

  • 박현정;황문정;이영주;장용민
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.130-130
    • /
    • 2002
  • Purpose: To evaluate the liver enhancement pattern of MR images obtained after administration of manganese phthalocyanine (MnPC), which is a newly developed macromolecular MR contrast agent, In experimentally implanted VX2 tumor of rabbits and compare with G4-DTPA and Mn-DPDP.

  • PDF

MR조영제와 분자영상 (MR Contrast Agents and Molecular Imaging)

  • 문우경
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

  • Jongmin J. Lee;Phillip J. Tirman;Yongmin Chang;Hun-Kyu Ryeom;Sang-Kwon Lee;Yong-Sun Kim;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.142-151
    • /
    • 2000
  • Objective: To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods: Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results: Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion: The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method.

  • PDF

Magnetic Resonance Enhancement Pattern as a Predictor of Cement Volume in Vertebroplasty Procedures for Osteoporotic Fractures

  • Lee, Kye Ho;Yoo, Dong Soo;Kim, Yoon Ha
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권3호
    • /
    • pp.148-153
    • /
    • 2017
  • Purpose: To identify the differences between injected cement volumes during vertebroplasty procedures according to the enhancement pattern of pre-procedure magnetic resonance imaging (MRI) findings. Materials and Methods: Thirty-two patients who underwent 52 vertebroplasty procedures as well as pre-procedure contrast-enhanced spine MRI in the authors' institution were reviewed retrospectively. The 52 procedures were divided into two groups according to different enhancement patterns shown by pre-procedure MR imaging [E(+) and E(-)]. The volumes of the enhancing/non-enhancing portions of the fractured vertebral body shown by pre-procedural MR imaging were calculated and compared to the volumes of the injected cement during the vertebroplasty procedures. Results: The 52 injections included 28 (56%) in Group E(+) and 24 (44%) in Group E(-). The actual volume ratio of the injected cement to the volume of the non-enhanced or enhanced region calculated based on the contrast-enhanced MRI was $0.22{\pm}0.11(cc/cm^3)$ in the E(+) group and $0.93{\pm}0.62(cc/cm^3)$ in the E(-) group. The average amount of injected cement was significantly different between Group E(+) and Group E(-) (P < 0.001). In addition, the ratio of the injected cement amount to the volume of the enhanced or non-enhanced portion based on the contrast-enhanced MRI in Group E(-) was significantly higher than that of Group E(+) (P < 0.001). Conclusion: Different enhancement patterns shown by pre-procedure MRI can predictors of the injected cement volume during vertebroplasty procedures for osteoporotic fractures.

Dynamic Contrast-Enhanced MR Imaging of Tietze's Syndrome: a Case Report

  • Kim, Dong Chan;Kim, Sang Yoon;Kim, Bong Man
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.55-60
    • /
    • 2020
  • Tietze's syndrome is an inflammatory condition associated with painful swelling of the costochondral, costosternal, and sternoclavicular joints. Tietze's syndrome has been mostly attributed to microtrauma until now; however, this etiology is currently disputed. The diagnosis is based on clinical findings, although a few studies suggest the advantages of imaging. We report a case of Tietze's syndrome with a review of radiological findings, especially magnetic resonance imaging (MRI) with dynamic contrast enhancement.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Magnetic Resonance Imaging Evaluation of the Prostate in Normal Dogs

  • Cho, Yu-Gyeong;Choi, Ho-jung;Lee, Ki-ja;Lee, Youngwon
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.317-323
    • /
    • 2020
  • The aims of this study were to describe the appearance and size of the normal canine prostate using magnetic resonance (MR) imaging and to calculate the apparent diffusion coefficient (ADC) values. MR images were obtained from seven intact male beagle dogs using a 1.5 T MR unit. The sequences included pre- and post-contrast T1- and T2-weighted imaging with and without fat saturation. The signal intensity of the prostate was compared with the adjacent musculature, fat, and urine in the urinary bladder. We recorded the mean prostatic length, width, and height and the length of the sixth lumbar vertebral body (L6). In addition, the prostatic length (rL), width (rW), and height (rH) ratios to L6 were calculated. Diffusion-weighted images of the prostate were obtained and ADC values were calculated. The prostate was bilobed and oval-shaped, homogenous on T1-weighted images, and heterogeneous with radiating lines on T2-weighted images. Post-contrast T1-weighted sequences showed contrast enhancement of the central and radiating striations. The prostatic capsule was clearly identified on post-contrast T1-weighted images with fat saturation. The ADC values were 1.72-2.04 × 10-3mm2/sec (mean, 1.88 × 10-3mm2/sec). Knowledge of the normal appearance of the prostate on MR images is essential to assess prostatic diseases in dogs.

Experimental Cats Model for Research of the Blood Ocular Barrier

  • Park Byung-Rae
    • 대한의생명과학회지
    • /
    • 제11권4호
    • /
    • pp.555-559
    • /
    • 2005
  • Evaluate the triolein emulsion could disrupt the barriers and to suggest as an experimental model in blood-ocular barrier studies. Triolein emulsion was infused into the carotid artery in the experimental group ten cats. Normal saline was used in another the control group ten cats. Pre contrast and postcontrast T1-weighted MR images were obtained at 30 minutes and 3 hours after embolization. Signal intensities were evaluated in the anterior, posterior chamber and in the vitreus qualitatively and quantitatively. Postembolization 30 minutes MR images were not different from those of the control group. Postembolization 3 hour MR images demonstrated delayed contrast enhancement in the anterior chamber of the ipsilateral and contralateral eyeballs and in the posterior chamber of the ipsilateral eyeball. Delayed contrast enhancement of the posterior chamber of the ipsilateral eyeball was statistically significant (P<0.05). The present study demonstrated significant contrast enhancement in the posterior chamber with infusion of triolein emulsion and can be a model in blood-aqueous barrier studies.

  • PDF

이하선에 발생된 양측성 Warthin 종양의 증례 (Bilateral Warthin tumor of the parotid gland: A case report)

  • 이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.57-62
    • /
    • 2008
  • The Warthin tumor is a benign neoplasm that occurs mostly in the parotid gland. The tumor frequently occurs in the tail of the parotid gland. A 75-year-old man was referred to Wonkwang dental hospital with a chief complaint of swelling on the right submandibular area. Numerous salivary stones were observed in the right submandibular gland on computed tomography (CT). And the two tumorous lesions were incidentally found in the parotid gland bilaterally. The tumorous lesions showed homogeneous enhancement on the CT and intermediate signal intensity on both T1- and T2-weighted magnetic resonance (MR) images. This tumorous lesions also showed contrast enhancement on fat suppressed T1 weighted MR images. We report common CT and MR features of this case of Warthin tumor in the parotid gland with literature review.

  • PDF