• Title/Summary/Keyword: Magnetic recording

Search Result 367, Processing Time 0.019 seconds

A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare (스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구)

  • Lee, Seong-Su;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Byoung-Hun;Kim, Kyeoung-Seop;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.917-927
    • /
    • 2018
  • High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.

Performance Evaluation of LDPC-LDPC Product Code for next Magnetic Recording Channel (차세대 자기기록 채널을 위한 LDPC-LDPC 곱 부호의 성능 평가)

  • Park, Donghyuk;Lee, Jaejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.3-8
    • /
    • 2012
  • Two-dimensional product code has been studied for correcting burst errors on the storage systems. An RS-LDPC product code consists of an RS code in horizontal direction and an LDPC code in vertical direction. First, we detect the position of burst errors by using RS code, then LDPC code corrects the errors by using the burst error positions. In storage system, long burst errors are occurred by various reason. So, we need a strong code for correcting the long burst errors. RS-LDPC product code is good for long burst errors. However, as the storage density grows the length of the burst errors will be longer. Thus, we propose an LDPC-LDPC product code, it is strong for correcting the very long burst errors. Also, the proposed LDPC-LDPC product code performs better than RS-LDPC product code when the random errors are occurred, because a row direction LDPC code performs better than row direction RS code.

Efficient In Vitro Labeling Rabbit Bone Marrow-Derived Mesenchymal Stem Cells with SPIO and Differentiating into Neural-Like Cells

  • Zhang, Ruiping;Li, Jing;Li, Jianding;Xie, Jun
    • Molecules and Cells
    • /
    • v.37 no.9
    • /
    • pp.650-655
    • /
    • 2014
  • Mesenchymal stem cells (MSCs) can differentiate into neural cells to treat nervous system diseases. Magnetic resonance is an ideal means for cell tracking through labeling cells with superparamagnetic iron oxide (SPIO). However, no studies have described the neural differentiation ability of SPIO-labeled MSCs, which is the foundation for cell therapy and cell tracking in vivo. Our results showed that bone marrow-derived mesenchymal stem cells (BM-MSCs) labeled in vitro with SPIO can be induced into neural-like cells without affecting the viability and labeling efficiency. The cellular uptake of SPIO was maintained after labeled BM-MSCs differentiated into neural-like cells, which were the basis for transplanted cells that can be dynamically and non-invasively tracked in vivo by MRI. Moreover, the SPIO-labeled induced neural-like cells showed neural cell morphology and expressed related markers such as NSE, MAP-2. Furthermore, whole-cell patch clamp recording demonstrated that these neural-like cells exhibited electrophysiological properties of neurons. More importantly, there was no significant difference in the cellular viability and $[Ca^{2+}]_i$ between the induced labeled and unlabeled neural-like cells. In this study, we show for the first time that SPIO-labeled MSCs retained their differentiation capacity and could differentiate into neural-like cells with high cell viability and a good cellular state in vitro.

Amorphous Cr-Ti Texture-inducing Layer Underlying (002) Textured bcc-Cr alloy Seed Layer for FePt-C Based Heat-assisted Magnetic Recording Media

  • Jeon, Seong-Jae;Hinata, Shintaro;Saito, Shin
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.35-39
    • /
    • 2016
  • $Cr_{100-x}Ti_x$ amorphous texture-inducing layers (TIL) were investigated to realize highly (002) oriented $L1_0$ FePt-C granular films through hetero-epitaxial growth on the (002) textured bcc-$Cr_{80}Mn_{20}$ seed layer (bcc-SL). As-deposited TILs showed the amorphous phase in Ti content of $30{\leq}x(at%){\leq}75$. Particularly, films with $40{\leq}x{\leq}60$ kept the amorphous phase against the heat treatment over $600^{\circ}C$. It was found that preference of the crystallographic texture for bcc-SLs is directly affected by the structural phase of TILs. (002) crystallographic texture was realized in bcc-SLs deposited on the amorphous TILs ($40{\leq}x{\leq}70$), whereas (110) texture was formed in bcc-SLs overlying on crystalline TILs (x < 30 and x > 70). Correlation between the angular distribution of (002) crystal orientation of bcc-SL evaluated by full width at half maximum of (002) diffraction (FWHM) and a grain diameter of bcc-SL indicated that while the development of the lateral growth for bcc-SL grain reduces FWHM, crystallization of amorphous TILs hinders FWHM. $L1_0$ FePt-C granular films were fabricated under the substrate heating process over $600^{\circ}C$ with having different FWHM of bcc-SL. Hysteresis loops showed that squareness ($M_r/M_s$) of the films increased from 0.87 to 0.95 when FWHM of bcc-SL decreased from $13.7^{\circ}$ to $3.8^{\circ}$. It is suggested that the reduction of (002) FWHM affects to the overlying MgO film as well as FePt-C granular film by means of the hetero-epitaxial growth.

Fabrication of Electrostatic Track-Following Microactuator for Hard Disk Drive Using SOI (SOI를 이용한 하드 디스크 드라이브용 정전형 트랙 추적 마이크로 액추에이터의 제작)

  • Kim, Bong-Hwan;Chun, Kuk-Jin;Seong, Woo-Kyeong;Lee, Hyo-Jung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.1-8
    • /
    • 2000
  • We have achieved a high aspect ratio track-following microactuator (TFMA) which is capable of driving 0.3 ${\mu}m$ magnetic head for hard disk drive (HDD). it was fabricated on silicon on insulator (SOI) wafer with 20 ${\mu}m$ trick active silicon and 2 ${\mu}m$ thick thermally grown oxide and piggyback electrostatic principle was used for driving TFMA. The first vibration mode frequency of TFMA was 18.5 kHz which is enough for a recording density of higher than 10 Gb/in$^2$. Its displacement was 1.4 ${\mu}m$ when 15 V dc bias plus 15 V ac sinusoidal driving input was applied and its electrostatic force was 50 N. The fabricated actuator shows 7.51 dB of gain margin and 50.98$^{\circ}$ of phase margin for 2.21 kHz servo-bandwidth.

  • PDF

Relationship between Forward Head Posture and Craniomandibular Disorders (두개하악장애와 두부전방자세와의 관계)

  • Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.137-149
    • /
    • 1994
  • This study was performed to investigate the relationship between Forward Head Posture(FHP) and Craniomandlbular Disorders(CMDs). Many studies reported that there was some relationship between them, however, there is still controversy. So It Is necessary to observe and compare many more patients with CMDs wirh normal controls. For the study 85 patients with CMDs and 37 dental students were selected as experimentals and controls, respectively. And the experimentals were classified Into two groups, that is, TMJ internal derangement group and muscle disorders group according to clinical diagnosis. For measuring the FHP, CROM(Cervical-Range-of-Notion)was used. This goniometer is composed of three part. First, gravity goniometer for flexion and extension. Second, magnetic compass and yoke for rotational movement. And last, forward head arm and vertebra locator for forward head posture. Next T-Scan, electronic occlusal analyzer, was used for recording of occlusal contact state. Other items such as maximum opening, lateral excursion, Helkimo's anamnestic index, and muscle palpation point from Friction's craniomandibular index were checked clinically by one examiner. The result of this study were as follows : 1. In male, control group showed much more measurement in resting forward head posture than did experimental group. But there were not significant differences between groups in female subject. From this results, the author contended that CROM is new measuring system and differ from other goniometers in some aspect, so that results should be re-evaluated 2. Mean value of maximum mouth opening in nearly all groups were greater than 40mm. and mouth opening had a significant correlation with occlusal force and with anamnestic index both sex. 3. Mean value of palpation point had not any correlationship with forward head posture in both sex, but there was significant difference between upper and lower group by rounded shouldes. 4. In summary, there was no significant relationship between forward head posture and sign and symptom of Craniomandibular Disorders.

  • PDF

Magneto-Optical Properties of MnSbPt Thin Films Prepared by RF Magnetron Sputtering (RF Magnetron Sputtering으로 제작된 MnSbPt 합금박막의 자기광학적 성질)

  • 송영민;이경재;김종오
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.93-97
    • /
    • 1996
  • The effects of annealing after deposition on the magnetic and magneto-optical properties of MnSbPt thin films prepared by rf sputtering were investigated. The MnSbPt alloy thin films were annealed in a vacuum with $10^{-5}$ Torr and the air, respectively, as a function of temperature and time. The films annealed at $300^{\circ}C$ for 4 hours was found to have the highest value of the saturation magnetization. The films annealed in the air did not show any thermal degradations, which indicates their chemical stability for the magneto-optical recording process. It was revealed that the $Mn_{43}Sb_{46}Pt_{11}$ films annealed at $300^{\circ}C$ for 4hours in a vacuum with $10^{-5}$ Torr exhibit high Kerr rotation angle of $0.8^{\circ}$ for the incident wavelength of 550nm, which is ascribed to the increase of the volume ratio of Clb phase. However, similar to the PtMnSb alloy thin films, these films are still horizontally magnetized and have the coercive field less than 400 Oe.

  • PDF

Statistics on Radiation Field Waveforms Associated with Multiple Intracloud Lightning Discharges

  • Lee, Bok-Hee;Lee, Dong-Moon;Ahn, Chang-Hwan;Kim, Young-Bong
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 2001
  • This paper presents the detailed statistics on radiation field signatures associated with multiple-intracloud lightning discharges. A transient signal recording system was used to measure the electric and magnetic fields produced by lightning flashes. The measurements were made in th summers of 1995 through 1999, and the location of the observation station was in Inchon on the coast of the Yellow Sea in Korea(37$^{\circ}$25'N, 126$^{\circ}$ 39'E). Most of lightning flashes typically contains between two and five strokes. The individual intracloud stork radiation fields were the bipolar pulse. On the average, the ratio of the peak of the second stroke to the first stroke peak was 75.1$\pm$40.1% for the negative, and a fraction of the subsequent stroke peaks were higher than the first stroke peak. The greater the number of the subsequent stroke order, less time separations between strokes were produced. The mean of the depth of the dip was 81.2$\pm$27.9% for the positive polarity and 75.9$\pm$24.4% for the negative. The depth of the dip increased for the positive bipolar pulses and decreased for the negative as the number of the stroke order increased.

  • PDF

Characteristics of the Electric Fields Produced by Multiple Lightning Return Strokes (다중 낙뢰에 의해서 발생한 전장 파형의 특성)

  • 이복희;정동철;이동문
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.330-336
    • /
    • 2004
  • In this work, in order to obtain the detailed information about lightning electromagnetic pulses, the electric fields radiated from multiple lightning return strokes were measured and analyzed statistically. The electric field measuring system consists of a hemisphere antenna of 30cm in diameter, integrator and data acquisition device, and its frequency bandwidth ranges from 200Hz to 1.56MHz, and the sensitivity is 0.96㎷/V/m. The electric field signals are digitized every 200ns with the transient signal analyzer having the resolution of 12-bit and the recording length of 5 kilowords and are registered at personal computer. As a result, the electric fields produced by the first return stroke begin with a slow initial part or front, which starts just after or during the last stepped leader. On the average the rise times of the electric fields for the positive first, second and third strokes are 4.21${\mu}\textrm{s}$, 3.94${\mu}\textrm{s}$ and 2.75${\mu}\textrm{s}$, respectively, and those for the negative first, second and third strokes are 3.46${\mu}\textrm{s}$, 3.15${\mu}\textrm{s}$ and 2.79${\mu}\textrm{s}$, respectively. The zero-crossing times of the electric fields for first return strokes range from about 10 to 80${\mu}\textrm{s}$. The mean zero-crossing times for subsequent return strokes are shorter than those for first lightning return strokes.

Visual Evoked Potentials in Retrochiasmal Lesion; Correlation with Neuroimaging Study (시각유발전위 검사상 후-시신경교차부위병변을 보인 환자들의 뇌 영상 결과와의 연관성)

  • Kim, Sung Hun;Cho, Yong-Jin;Kim, Ho-Jin;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • Background and Objective : Visual evoked potentials(VEPs) is considered to be a reliable diagnostic procedure for examining patients with anterior visual pathways. Some abnormalities in the recordings on monocular stimulation have been said to indicate retrochiasmal lesion, but less consistent results have been reported. This study is to evaluate the positive predictability of VEP for the detection of retrochiasmal lesion. Methods : We reviewed VEPs that could be interpreted as indicative of a retrochiasmal lesions, based on amplitude or latency asymmetry recorded on the left(O1) and right(O2) occipital regions. Bilateral absent VEPs on both recording(O1 and O2) without evidence of prechiasmal lesion were included. During 5 years, we identified 31 patients who met the above criteria and who had undergone magnetic resonance imaging(MRI) of brain(one patient underwent computerized tomography). Twenty three patients underwent pattern reversal VEPs and others underwent flash goggle VEPs. Results : Brain imagings were abnormal in 29 and were normal in 2. Of the 29 abnormal scans, lesions in posterior visual pathway were detected in 21 scans(predictive value=68%). The predictive value was not significantly different between flash goggle VEP(75%) and pattern reversal VEP(68%). The predictive value was higher in patient with visual field defect(100%) than those without visual field defect(25%). The pathologic nature of lesion also showed close relations to the predictive value. VEPs is usually paradoxically lateralized(78%), but not in all patients. Conclusion : VEPs abnormalities suggesting retrochiasmal lesion were usually corresponded with brain MRI findings. Diagnostic reliability could be increased when considering the visual field defect and nature of lesion. Therefore, the authors suggest that VEPs studies could be useful in evaluating the patients with the retrochismal lesion.

  • PDF