• Title/Summary/Keyword: Magnetic material

Search Result 1,943, Processing Time 0.033 seconds

Making Process for Magnetite Powder (Magnetite 분말의 제조)

  • Ho-Sang Lee;Kyu-Jin Kim
    • Resources Recycling
    • /
    • v.9 no.5
    • /
    • pp.28-32
    • /
    • 2000
  • In this study, the new processing method to produce magnetite for mono-component black toner was studied using spray roaster. The produced magnetite is compared with TMB 125 made by Magnox, USA. When the weight ratio of the ferrous chloride and the ferric chloride is varied from 3:7~7:3 under $N_2$ atmosphere, the 100% major phase of magnetite is obtained. However, when the content of he ferrous chloride is higher than 70wt%, the content of FeO is increased. The phase of $\Gamma-Fe_2O_3$ is shown in th range of over 70wt% of the ferric chloride. The magnetite produced by spray roasting has a saturation magnetization of 80~85 emu/g and a coercivity of 110~130 Oe. The shape of the particle is irregular sphere and hte size of the magnetite is the range of $0.3~0.5\mu\textrm{m}$. It is shown that the magnetite made by spary roasting is enough to apply to the magnetic material of toner.

  • PDF

Preparation and Properties of Poly(organosiloxane) Rubber Nanocomposite Containing Ultrafine Nickel Ferrite Powder (Nickel Ferrite 함유 Poly(organosiloxane) Rubber Nanocomposite의 제조와 특성)

  • Kang Doo Whan;Lee Kweon Soo
    • Polymer(Korea)
    • /
    • v.29 no.2
    • /
    • pp.156-160
    • /
    • 2005
  • $\alpha,\omega-Vinyl$ poly (dimethyl-methylphenyl) siloxane prepolymer (VPMPS ) was prepared by the equilibrium polymerization of octamethylcyclotetrasiloxane $(D_4)$, 1,3,5-trimethyl-1,3,5-triphenylcyclotrisiloxane $(D_3^{Me,Ph)$, and 1,1,3,3-tetramethyl-1,3-divinyldisiloxane (MVS). And also, of $\alpha,\omega-hydrogen$ poly(dimethyl-methyl)siloxane prepolymer (HPDMS) as end blocker was prepared from octamethylcyclotetrasiloxane $(D_4)$, 1,3,5-trimethylcyclotrisiloxane $(D_3^:Me,H})$, and 1,1,3,3-tetramethyldisiloxane (MS). Nickel ferrite nanoparticles having spinel magnetic material was prepared by the sol-gel method using PAA as a chelating agent. Poly(organosiloxane) rubber nanocomposite containing silica and nickel ferrite ultrafine powder modified with 1,3-divinyltetramethyldisilazane (VMS) was prepared by compounding VPMPS, HPDMS, and catalyst in high speed dissolver. The mechanical properties, heat dissipating away characteristics, and volume resistivities for POX-30 and POX-50 were measured.

A Case Study on the MRI Profitability of a General Hospital (한 종합병원의 MRI 채산성 사례 연구)

  • Kang, Chang-Yeol;Song, Sung-Ho;Lim, Kyeong-Tae
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

Cerebral Hemodynamic Analysis in Pediatric Moyamoya Patients using Perfusion Weighted MRI (관류 강조 자기공명 영상을 이용한 소아 모야모야 환아의 뇌 혈역학 분석)

  • Chang, Won-Seok;Kim, Tae-Gon;Lee, Seung-Koo;Choi, Jung-Uhn;Kim, Dong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.207-212
    • /
    • 2005
  • Objective: Classically, single photon emission tomography is known to be the reference standard for evaluating the hemodynamic status of patients with moyamoya disease. Recently, T2-weighted perfusion magnetic resonance(MR) imaging has been found to be effective in estimating cerebral hemodynamics in moyamoya disease. We aim to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic status of moyamoya disease. Methods: The subjects were fourteen moyamoya patients(mean age: 7.21 yrs) who were admitted at our hospital between Sep. 2001 to Sep 2003. Four normal children were used for control group. Perfusion MR imaging was performed before any treatment by using a T2-weighted contrast material-enhanced technique. Relative cerebral blood volume(rCBV) and time to peak enhancement(TTP) maps were calculated. Relative ratios of rCBV and TTP in the anterior cerebral artery(ACA), middle cerebral artery(MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery(PCA) in each cerebral hemispheres. Using this data, we analysed the hemodynamic aspect of pediatric moyamoya disease patients in regarding to the age, Suzuki stage, signal change in FLAIR MR imaging, and hemispheres inducing symptoms. Results: The mean rCBV ratio of ACA, MCA did not differ between normal children and moyamoya patients. However the significant TTP delay was observed at ACA, MCA territories (mean = 2.3071 sec, 1.2089 see, respectively, p < 0.0001). As the Suzuki stage of patients is advanced, rCBV ratio is decreased and TTP differences increased. Conclusion: Perfusion MR can be applied for evaluating preoperative cerebral hemodynamic status of moyamoya patients. Furthermore, perfusion MR imaging can be used for determine which hemisphere should be treated, first.

Repeated Transsphenoidal Surgery for Pituitary Tumors (경접형골동접근법에 의한 뇌하수체종양의 재수술)

  • Koh, Young-Cho;Yoo, Heon;Kim, Chang-Hyun;Whang, Do-Yun;Jang, Jin-Soon;Park, Hyo-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.929-934
    • /
    • 2000
  • Objective : The results of secondary transsphenoidal surgery(TSS) for either residual or recurring pituitary adenomas have been reported to be unfavorable. To evaluate the effectiveness of secondary TSS, we analyzed the surgical results of residual or recurred pituitary adenomas in patients who underwent secondary TSS from 1992 to 1998. Material and Methods : Among the 95 patients who underwent TSS during this period, 14(15%) received repeated TSS. Two of the 14 patients underwent three TSS. Among the 11 patients with pituitary adenomas, three had nonfunctioning tumors ; six prolachnomas ; two GH-secreting adenomas. The remaining three patieats had craniopharyngioma, pituitary abscess and hemangioendothelioma respectively. The interval between the two surgical procedures ranged from one week to 33 months(mean ; 12 months). Causes of the secondary TSS were tumor recurrence in 11 patients, intentional staged operation in three, persistent disease despite medical therapy and CSF leak after initial operation in one respectively. Treatments prior to secondary TSS were medical treatment only in eight patients. Results : During the repeated operationtss some adhesion was noted in septal mucous membrane. The sphenoid cavity was filled with fibrous tissue which correlated with the methods of reconstruction of the sellar floor at the previous operation. There was no statistically significant difference in success rate of surgery between the initial and the second TSS(86% vs 81%). The complication rate was similar between the two procedures. There was no statistically significant factors affecting the results of second TSS. Conclusion : Transsphenoidal reoperation was regarded as a suitable approach for treating recurrent pituitary adenomas in spite of some degree of operative difficulties. In patients with transsphenoidally resectable tumor residuals or recurrences confirmed by magnetic resonance imaging, remissions can be obtained with high probability, especially in secondary surgery after an staged decompression.

  • PDF

Buckling behavior of smart MEE-FG porous plate with various boundary conditions based on refined theory

  • Ebrahimi, Farzad;Jafari, Ali
    • Advances in materials Research
    • /
    • v.5 no.4
    • /
    • pp.279-298
    • /
    • 2016
  • Present disquisition proposes an analytical solution method for exploring the buckling characteristics of porous magneto-electro-elastic functionally graded (MEE-FG) plates with various boundary conditions for the first time. Magneto electro mechanical properties of FGM plate are supposed to change through the thickness direction of plate. The rule of power-law is modified to consider influence of porosity according to two types of distribution namely even and uneven. Pores possibly occur inside FGMs due the result of technical problems that lead to creation of micro-voids in these materials. The variation of pores along the thickness direction influences the mechanical and physical properties. Four-variable tangential-exponential refined theory is employed to derive the governing equations and boundary conditions of porous FGM plate under magneto-electrical field via Hamilton's principle. An analytical solution procedure is exploited to achieve the non-dimensional buckling load of porous FG plate exposed to magneto-electrical field with various boundary condition. A parametric study is led to assess the efficacy of material graduation exponent, coefficient of porosity, porosity distribution, magnetic potential, electric voltage, boundary conditions, aspect ratio and side-to-thickness ratio on the non-dimensional buckling load of the plate made of magneto electro elastic FG materials with porosities. It is concluded that these parameters play remarkable roles on the dynamic behavior of porous MEE-FG plates. The results for simpler states are confirmed with known data in the literature. Presented numerical results can serve as benchmarks for future analyses of MEE-FG plates with porosity phases.

Thermal Analysis of TRIO-CINEMA Mission

  • Yoo, Jae-Gun;Jin, Ho;Seon, Jong-Ho;Jeong, Yun-Hwang;Glaser, David;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • Thermal analysis and control design are prerequisite essential to design the satellite. In the space environment, it makes satellite survive from extreme hot and cold conditions. In recent years CubeSat mission is developed for many kinds of purpose. Triplet Ionospheric Observatory (TRIO)-CubeSat for Ion, Neutral, Electron, MAgnetic fields (CINEMA) is required to weigh less than 3 kg and operate on minimal 3 W power. In this paper we describe the thermal analysis and control design for TRIO-CINEMA mission. For this thermal analysis, we made a thermal model of the CubeSat with finite element method and NX6.0 TMG software is used to simulate this analysis model. Based on this result, passive thermal control method has been applied to thermal design of CINEMA. In order to get the better conduction between solar panel and chassis, we choose aluminum 6061-T6 for the material property of standoff. We can increase the average temperature of top and bottom solar panels from $-70^{\circ}C$ to $-40^{\circ}C $ and decrease the average temperature of the magnetometer from $+93^{\circ}C$ to $-4^{\circ}C$ using black paint on the surface of the chassis, inside of top & bottom solar panels, and magnetometer.

Remote Epidural Hematoma Following the Removal of Brain Tumors : Report of Three Cases (뇌종양 제거 후 원격부위에 발생한 뇌경막외혈종 - 증례보고 -)

  • Bae, Kwang-Ju;Kim, Ill-Man;Yim, Man-Bin
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.366-370
    • /
    • 2001
  • Objective : The authors present three cases of brain tumors in which epidural hematomas(EDHs) were developed postoperatively in the remote areas from craniotomy sites. The preventive tactics as well as possible mechanisms of development of remote EDH are discussed. Material and Methods : The magnetic resonance imagings of three patients revealed a left lateral ventricular mass located just aside of foramen Monro in a 27-year-old male, a large cystic mass in the temporal lobe in a 35-year-old male, and a partially calcified pineal mass in a 27-year-old male patient. The surgical removals of these tumors were performed without any noticeable events during surgery via left frontal transcortical transventricular approach for lateral ventricular tumor, left temporal craniotomy for cystic temporal tumor, and right occipital transtentorial approach for pineal tumor. Results : Postoperative EDHs remote from the sites of craniotomy were detected by the immediate postoperative computerized tomographic scans. We obtained good outcomes without any morbidity in all three patients with emergent evacuation of the hematoma. The pathologic diagnoses were lateral ventricular ependymoastrocytoma, temporal craniopharyngioma and mixed germinoma of the pineal region. Conclusion : It is postulated that a sudden reduction of intracranial pressure(ICP) at the time of tumor removal may strip the dura from the inner table of the skull to cause EDH from the remote site of craniotomy. Gradual reduction of ICP with slow drainage of cerebrospinal fluid before tumor removal as well as lowering the head position of patient during surgery might be helpful for preventing this unusual complication.

  • PDF

Low Temperature Sintering Mg-Zn Ferrites (Mg-Zn Ferrites의 저온소결화)

  • Kwon Oh-Heung
    • Resources Recycling
    • /
    • v.12 no.6
    • /
    • pp.8-12
    • /
    • 2003
  • According to the recent trend to raise the horizontal scan frequency to increase the image refinement of the High Definition TV and High Resolution Display, material with low core loss is required for the ferrite core for deflection yoke, which is secured even in the high frequency range. liking notice of the influence on the fine structure of Mg-Zn ferrite by the chemical com position and process, low temperature sintering was proceeded. Cu was added to the low loss Mg-Zn system ferrite. After select-ing MgO, ZnO, $Fe_2$$O_3$, CuO, MgO was substituted for CuO while varying the composition ratio. Then the sample was sintered for 3 hours between $980~1350^{\circ}C$ Magnetic permeability, power consumption, shrinkage rate, core loss were measured. The start-ing temperature to test the shrinkage of the sample was nearby $900^{\circ}C$, it increased according to the substitution process of Cu, and the firing temperature was lowered about $-50~-75^{\circ}C$ alongside of the process.

Development and Synthesis of La Doped CuO-ZnO-Al2O3 Mixed Oxide (La이 도핑된 CuO-ZnO-Al2O3 복합 산화물의 합성공정개발)

  • Jung, Mie-Won;Lim, Saet-Byeol;Moon, Bo-Ram;Hong, Tae-Whan
    • Korean Journal of Materials Research
    • /
    • v.21 no.1
    • /
    • pp.67-71
    • /
    • 2011
  • La doped CuO-ZnO-$Al_2O_3$ powders are prepared by sol-gel method with aluminum isopropoxide and primary distilled water as precursor and solvent. In this synthesized process, the obtained metal oxides caused the precursor such as copper (II) nitrate hydrate and zinc (II) nitrate hexahydrate were added. To improve the surface areas of La doped CuO-ZnO-$Al_2O_3$ powder, sorbitan (z)-mono-9-octadecenoate (Span 80) was added. The synthesized powder was calcined at various temperatures. The dopant was found to affect the surface area and particle size of the mixed oxide, in conjunction with the calcined temperature. The structural analysis and textual properties of the synthesized powder were measured with an X-ray Diffractometer (XRD), a Field-Emission Scanning Electron Microscope (FE-SEM), Bruner-Emmett-Teller surface analysis (BET), Thermogravimetry-Differential Thermal analysis (TG/DTA), $^{27}Al$ solid state Nuclear Magnetic Resonance (NMR) and transform infrared microspectroscopy (FT-IR). An increase of surface area with Span 80 was observed on La doped CuO-ZnO-$Al_2O_3$ powders from $25m^2$/g to $41m^2$/g.