• Title/Summary/Keyword: Magnetic manipulation

Search Result 49, Processing Time 0.028 seconds

Management of Disc Displacement with Retrodiscitis after Macrotrauma: A Case Report

  • Tae-Seok Kim;Yeon-Hee Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • We present the case of a 60-year-old male with post-macrotrauma disc displacement and retrodiscitis, in which temporomandibular joint (TMJ) injection and manual therapy were used to alleviate his symptoms. He visited our clinic with complaints of pain and swelling in his right facial area and malocclusion of his right side teeth after being hit on the right side of his face five days earlier. During clinical and radiological examinations, the inflammatory state of the joint and disc displacement on the right side, which led to malocclusion, were noted. At the initial visit, we performed TMJ intracapsular injection and prescribed medications to control pain and inflammation. Simultaneously, manual manipulation was performed to relocate the disc. The same treatments were employed two days later. However, 10 days after the first visit, his symptoms did not mitigate substantially. We also performed magnetic resonance imaging (MRI), prescribed nortriptyline, and created a stabilization splint. MRI images depicted inflammatory disc displacement and joint effusion in the right TMJ. Based on the accurate diagnosis, we kept administering a stabilization splint, intra-articular injection, and medication. His signs and symptoms were alleviated 20 days after the initial visit and did not reoccur for the next 40 days.

Current Reference Adjustment Method Using Null Space Vector Injection in Magnetic Manipulation System (Null space 전류 벡터 주입을 통한 자기장 합성 시스템 전류 지령 수정방법)

  • Hong, Jin-Su;Lee, Jun;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.41-42
    • /
    • 2017
  • 기존의 다중 코일을 이용한 소형 자성체를 제어하는 시스템에서 전류 벡터 지령은 구동 매트릭스의 pseudo-inverse를 사용하여 계산되었다. 본 논문에서는 기존의 전류 지령에 null space 전류 벡터 지령을 더하는 방법을 이용하여 현재 전류 벡터값과 목표 전류 벡터 지령 사이의 전류 변화량이 최소화 되는 전류 지령 수정 방식을 제안한다. 제한된 전압 정격 내에서 제안된 방식을 적용할 경우 전류 지령 벡터값에 도달하는 시간이 짧아짐으로, 기존 방식에 비해 빠른 반응성을 얻을 수 있다. 제안된 방법은 Matlab(R) Simulink(R)를 통해 검증하였다.

  • PDF

DEVELOPMENT OF A POST-PROCESSING PROGRAM FOR VISUALIZATION OF MRI DATA (MRI Data 가시화용 후처리 프로그램 개발)

  • Myong, H.K.;Choi, H.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.67-72
    • /
    • 2007
  • A post-processing program based on the OOP(Object-Oriented Programming) concept has been developed for visualization of MRI. User-friendly GUl(Graphic User Interface) has been built on the base of MFC(Microsoft Foundation Class). The program is organized as modules by classes based on VTK-library, and these classes are made to function through inheritance and cooperation which are an important and valuable concept of object-oriented programming. The major functions of this post-processor program are introduced and demonstrated, which include contour plot, surface plots, cut plot and clip plot as well as view manipulation (translation, rotation, scaling etc).

  • PDF

Automatic Surface Matching for the Registration of LIDAR Data and MR Imagery

  • Habib, Ayman F.;Cheng, Rita W.T.;Kim, Eui-Myoung;Mitishita, Edson A.;Frayne, Richard;Ronsky, Janet L.
    • ETRI Journal
    • /
    • v.28 no.2
    • /
    • pp.162-174
    • /
    • 2006
  • Several photogrammetric and geographic information system applications such as surface matching, object recognition, city modeling, environmental monitoring, and change detection deal with multiple versions of the same surface that have been derived from different sources and/or at different times. Surface registration is a necessary procedure prior to the manipulation of these 3D datasets. This need is also applicable in the field of medical imaging, where imaging modalities such as magnetic resonance imaging (MRI) can provide temporal 3D imagery for monitoring disease progression. This paper will present a general automated surface registration procedure that can establish correspondences between conjugate surface elements. Experimental results using light detection and ranging (LIDAR) and MRI data will verify the feasibility, robustness, and accuracy of this approach.

  • PDF

RMS Current Limitation Method in Multi-Coil Magnetic Manipulation System (다중 코일 자기장 합성 시스템에서의 RMS 전류 제한방법)

  • Seo, Jeongjun;Hong, Jin-Su;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.117-118
    • /
    • 2018
  • 본 논문은 다중 코일 자기장 합성 시스템에서 RMS 전류를 제한하는 방법을 제안한다. 해당 방법은 기존의 전류 지령의 위상을 바꾸지 않으면서 전류 지령의 크기를 줄여 RMS 전류가 원하는 범위를 넘어가지 않도록 한다. 또한 해당 방법은 자기장 합성 시스템의 특성을 고려하여, 일부 전류 지령이 제한되는 경우에 다른 전류 지령들도 같은 비율로 줄여주는 방법을 포함한다. 제안된 방식을 적용하게 되면 RMS 전류 지령이 정격을 넘을 때에만 전류를 제한하여 일반적인 상황에서 과도하게 전류를 제한하는 것을 개선할 수 있다.

  • PDF

Detection and Manipulation of Spin state of Single Molecule Magnet: Kondo resonance and ESR-STM

  • Komeda, T.;Isshiki, H.;Zhang, Y.F.;Katoh, K.;Yoshida, Y.;Yamashita, M.;Miyasaka, H.;Breedlove, B.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.16-17
    • /
    • 2010
  • Molecular spintronics has attracted attentions, which combines molecular electronics with the spin degree of freedom in electron transport. Among various molecules as candidates of the molecular spintronics, single molecule magnet (SMM) is one of the most promising material. SMM molecules show a ferromagnetic behavior even as a single molecule and hold the spin information even after the magnetic field is turned off. Here in this report, we show the spin behavior of SMM molecules adsorbed on the Au surface by combining the observation of Kondo peak in the STS and ESR-STM measurement. Kondo resonance state is formed near the Fermi level when degenerated spin state interacts with conduction electrons. ESR-STM detects the Larmor frequency of the spin in the presence of a magnet field. The sample include $MPc_2$ and $M_2Pc_3$ molecules ($M\;=\;Tb^{3+}$, $Dy^{3+}$, and $Y^{3+}$ Pc=phthalocyanine) whose critical temperature as a ferromagnet reaches 40 K. A clear Kondo peak was observed which is originated from an unpaired electron in the ligand of the molecule, which is the first demonstration of the Kondo peak originated from electron observed in the STS measurement. We also observed corresponding peaks in ESR-STM spectra. [1] In addition we found that the Kondo peak intensity shows a clear variation with the conformational change of the molecule; namely the azimuthal rotational angle of the Pc planes. This indicates that the Kondo resonance is correlated with the molecule electronic state. We examined this phenomena by using STM manipulation technique, where pulse bias application can rotate the relative azimuthal angle of the Pc planes. The result indicates that an application of ~1V pulse to the bias voltage can rotate the Pc plane and the Kondo peaks shows a clear variation in intensity by the molecule's conformational change.

  • PDF

Persistent Trigeminal Artery Variant Detected by Conventional Angiography and Magnetic Resonance Angiography -Incidence and Clinical Significance-

  • Rhee, Sun-Joo;Kim, Myoung-Soo;Lee, Chae-Heuck;Lee, Ghi-Jai
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.6
    • /
    • pp.446-449
    • /
    • 2007
  • Objective : Persistent trigeminal artery variant (PTAV) is an anastomosis between the internal carotid artery (ICA) and the cerebellar artery without any interposing basilar artery segment. We discuss its probable embryological origin and emphasize clinical implications. Methods : Retrospectively 1250 conventional cerebral angiograms and 2947 cranial magnetic resonance angiographies (MRAs) were evaluated for the patients with PTAV. Results : Five patients (four men and one woman, 23 to 76 years of age, median age 65 years) had a PTAV. Three patients who underwent MRA had a PTAV (3/2947=0.1%). Four of the patients who underwent cerebral angiography had a PTAV (4/1250=0.32%). Two of 143 patients who underwent both conventional angiography and cranial MRA showed PTAV. The PTAV was an incidental finding in all five patients. The PTAV originated from the cavernous segment of the left ICA in four patients and from the cavernous segment of the right ICA in one patient. The terminal branch of the PTAV was the anterior inferior cerebellar artery (AICA) and superior cerebellar artery (SCA) in two patients and the AICA only in the other three patients. Conclusion : Neurosurgeons should be aware of possible presence of PTAV. Manipulation of this vessel during a surgical approach to the parasellar region and percutaneous gasserian ganglion procedure may result in hemorrhage or ischemia.

Acupuncture Stimulation for Motor Cortex Activities: Evidence from 3T Functional MRI Study

  • Choe, Bo-Young;Jeun, Sin-Soo;Kang, Sei-Kown;Park, Gi-Soon;Chung, Sung-Taek;Yoo, Seung-Schik;Chu, Myung-Ja;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.352-355
    • /
    • 2002
  • The purpose of this study was to investigate whether or not acupuncture of GB34 produces a significant response of the modulation of somatomotor areas by functional magnetic resonance imaging (fMRI) study. The acupoint, GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MRI scanner, functional MR imaging of the whole brain was performed in 12 normal healthy subjects during two stimulation paradigms; acupuncture manipulation on GB 34 and sham points. This study investigates the activation of the mortor cortex elicited by a soft and an intensified stimulation of GB 34. Three different paradigms were carried out to detect any possible modulation of the Blood Oxygenation Level Dependent (BOLD) response in the somatomortor area to motor stimulation through acupuncture. Group analysis from seven individuals showed that bilateral sensorimotor areas (BA 3,4,6 and 7) showed stimulation related BOLD signal contrast of approximately 6% whereas very few areas were activated when sham stimulation is given. The present study shows that acupuncture fMRI study can be safely conducted in 3T MRI environment, and acupuncture stimulation in GB34 modulates the cortical activities of the somatomotor area in human. The present findings may shed light on the CNS mechanism of motor function by acupuncture and form a basis for future investigations of motor modulation circuits in the stroke patients.

  • PDF

Magnetofection is an efficient tool for ectopic gene expression into oral cells

  • Ji, Jae-Hoon;Ko, Seon-Yle;Jang, Young-Joo
    • International Journal of Oral Biology
    • /
    • v.32 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • It is difficult to introduce DNA in non-invasive manner into oral cancer cells as well as primary cells for gene manipulation and expression in vivo. So far, several methods for a gene delivery have been performed to solve this problem. Magnetofection is one of the recent methods for gene transfer, and nanoparticles are applied under a magnetic field for DNA delivery. We investigated whether the magnetofection increases the efficiency of a gene delivery into several oral cell lines. By using a plasmid coding the green fluorescent protein (GFP), the efficiency of gene transfer by magnetofection was compared with those by using the calcium phosphate and the commercial transfection agent. Indeed, the magnetofection increased the green fluorescent signal in cells, suggested that this method apparently enhance the efficiency of gene delivery without any defects in various oral cancer cell lines. Finally, we have shown that magnetofection can be a useful technique for gene delivery to difficult-to-transfect cells to perform a functional study of genes in vivo.

Spontaneous Regression of a Radiculopathic Cervical Herniated Disc following Non-surgical Treatment -3 case reports- (비수술적 치료 후 자연소실된 경추추간판탈출증 -증례보고-)

  • Kim, Hyeun Sung;Jo, Dae Hyun;Park, In Ho;Rhu, Jae Kwang;Sun, Kwang Jin;Lim, Kyung Joon
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.84-88
    • /
    • 2008
  • The spontaneous regression of herniated cervical discs is not a well established phenomenon. However, we encountered the 3 cases of spontaneous regression of severe radiculopathic herniated cervical discs that were treated using a non-surgical method. Each of the patients were treated with a combination of manipulation, dry needling and analgesics. In each case, the symptoms improved within 12 months of treatment and magnetic resonance imaging (MRI) conducted at that time revealed marked regression of the herniated disc in all cases. These cases provide additional examples of spontaneous regression of herniated cervical discs documented by MRI following non-surgical treatment.