• Title/Summary/Keyword: Magnetic field map

Search Result 78, Processing Time 0.022 seconds

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging (자기공명영상을 이용한 금속전극의 정확한 위치 결정)

  • Joe, Eun-Hae;Ghim, Min-Oh;Ha, Yoon;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2011
  • Purpose : Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. Materials and Methods : Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional ($90^{\circ}$ view) and $45^{\circ}$ oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. Results : There was least field inhomogeneity along the $45^{\circ}$ line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with $45^{\circ}$ oblique-view was coincided regardless of susceptibility. And with $45^{\circ}$ oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the $45^{\circ}$ oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. Conclusion : We suggested the method for accurate localization of electrode using $45^{\circ}$ oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery.

Application of 40-channel SQUID Gradiometer System for the Comparison of Magnetocardiograms from Healthy Subjects and Patients with WPW syndrome and DCM (40 채널 SQUID 미분계 시스템을 이용한 정상인과 WPW 증후군 및 확장성 심근증 환자의 심자도 비교)

  • 정용석;권혁찬;김기웅;이용호;강찬석;김진목;박용기;김기영;박기락
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • The aim of this study is to confirm clinical usefulness of magnetocardiogram (MCG) by analyzing MCG data of health subjects and patients with Wolff-Parkinson-White (WPW) syndrome and dilated cardiomyopathy (DCM). Measurement of MCG signals was done with a home-made 40-channel SQUID system. MCG signals of 30 healthy subjects were measured as the reference of MCG signals. Among the DCM patients, 7 patients showed abnormal the direction of T wave vector. For a WPW syndrome patient, we measured the MCG signals before and after the surgery. and compared the difference. From the measured magnetic field distribution, current vector map was obtained to show the myocardium current activity. By comparing the MCG signals and current maps, we showed the differences in the analysis results between the healthy subjects and patients with heart diseases.

  • PDF

R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease (관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구)

  • Lim, Hyun-Kyoon;Yu, Kwon-Kyu;Kim, Jin-Mok;Kim, In-Seon;Kang, Chan-Seok;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF

Brain Mapping: From Anatomics to Informatics

  • Sun, Woong
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.184-187
    • /
    • 2016
  • Neuronal connectivity determines brain function. Therefore, understanding the full map of brain connectivity with functional annotations is one of the most desirable but challenging tasks in science. Current methods to achieve this goal are limited by the resolution of imaging tools and the field of view. Macroscale imaging tools (e.g., magnetic resonance imaging, diffusion tensor images, and positron emission tomography) are suitable for large-volume analysis, and the resolution of these methodologies is being improved by developing hardware and software systems. Microscale tools (e.g., serial electron microscopy and array tomography), on the other hand, are evolving to efficiently stack small volumes to expand the dimension of analysis. The advent of mesoscale tools (e.g., tissue clearing and single plane ilumination microscopy super-resolution imaging) has greatly contributed to filling in the gaps between macroscale and microscale data. To achieve anatomical maps with gene expression and neural connection tags as multimodal information hubs, much work on information analysis and processing is yet required. Once images are obtained, digitized, and cumulated, these large amounts of information should be analyzed with information processing tools. With this in mind, post-imaging processing with the aid of many advanced information processing tools (e.g., artificial intelligence-based image processing) is set to explode in the near future, and with that, anatomic problems will be transformed into informatics problems.

INVESTIGATING PLASMA-PHYSICAL PROPERTIES OF JETS IN NEARBY RADIO-BRIGHT AGN WITH KVN AND KaVA

  • KIM, JAE-YOUNG;TRIPPE, SASCHA;SOHN, BONG WON;OH, JUNGHWAN;PARK, JONG-HO;LEE, SANG-SUNG;LEE, TAESEOK
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.453-455
    • /
    • 2015
  • In this paper we introduce the Plasma Physics of Active Galactic Nuclei project, which is an ongoing experiment with Korean VLBI Network (KVN) and KVN and VERA Array (KaVA) to study multi-frequency polarimetric properties on parsec scales of active galaxies. The goal of the project is to improve our understanding of fundamental jet physics, especially evolution of the relativistic outflow coupled with the large-scale magnetic field. We selected six radio-loud AGN as our targets. So far we (i) detected resolved emissions regions at 86 and 129 GHz on VLBI scales, (ii) constructed 2D spectral index maps of the outflows, and (iii) found polarizations at 22 and 43 GHz for a few targets. Here we present spectral index distributions of 3C 120 between 22 and 43 GHz and a linear polarization map of BL Lac at 43 GHz obtained with KVN.

Investigation of Subsurface Structure of Cheju Island by Gravity and Magnetic Methods (중력 및 자력 탐사에 의한 제주도 지질구조 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Jung, Gwi-Geum;Chung, Seung-Whan
    • Economic and Environmental Geology
    • /
    • v.28 no.4
    • /
    • pp.395-404
    • /
    • 1995
  • The geologic structure of the Cheju volcanic island has been investigated by analyzing the gravity and magnetic data. Bouguer gravity map shows apparent circular low anomalies at the central volacanic edifice, and the maximum difference of the anomaly values on the island appears to be 30 mgal. The subsurface structure of the island is modeled by three-dimensional depth inversion of gravity data by assuming the model consists of a stacked grid of rectangular prisms of volcanic rocks bounded below by basement rocks. The gravity modeling reveals that the interface between upper volvanic rocks and underlying basement warps downward under Mt. Halla with the maximum depth of 5 km. Magnetic data involve aeromagnetic and surface magnetic survey data. Both magnetic anomaly maps show characteristic features which resemble the typical pattern of total magnetic anomalies caused by a magnetic body magnetized in the direction of the geomagnetic field in the middle latitude region, though details of two maps are somewhat different. The reduced-to-pole magnetic anomaly maps reveal that main magnetic sources in the island are rift zones and the Halla volcanic edifice. The apparent magnetic boundaries inferred by the method of Cordell and Grauch (1985) are relatively well matched with known geologic boundaries such as that of Pyosunri basalt and Sihungri basalt which form the latest erupted masses. Inversion of aeromagnetic data was conducted with two variables: depth and susceptibility. The inversion results show high susceptibility bodies in rift zones along the long axis of the island, and at the central volcano. Depths to the basement are 1.5~3 km under the major axis, 1~1.5 km under the lava plateau and culminates at about 5 km under Mt. Halla. The prominent anomalies showing N-S trending appear in the eastern part of both gravity and magnetic maps. It is speculated that this trend may be associated with an undefined fault developed across the rift zones.

  • PDF

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

Optimal Disposition of Direction Finder using EM Wave Propagation Analysis (전파환경분석을 통한 방향탐지기 최적배치에 관한 연구)

  • Yang, Jong-Won;Choi, Jun-Ho;Kwon, Do-Baeg;Kang, Hee-Seog;Park, Cheol-Sun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.170-179
    • /
    • 2007
  • This paper introduces the optimal disposition of direction finder using EM(Electro-magnetic) wave propagation analysis which is based on LR(Longley-Rice) propagation model and the characteristics of direction finder, emitter and terrain. Initial model is simulated and modified to minimize propagation error as a result of the field trials. Proposed analysis used line-of-sight analysis and mountain-top extraction algorithm to optimize the disposition in the assigned area and the result can be displayed in the 3D map in order of the percentage coverage for direction finding possibility area.

Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator (발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석)

  • Seong, Minyoung;Kim, Doo-Hyun;Kim, Seungtae
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.