• Title/Summary/Keyword: Magnetic field gradient

Search Result 217, Processing Time 0.023 seconds

A Fundamental Study on the Electron Behavior and Optimum Condition for the Formation of a Neutral Loop Discharge Plasma (Neutral Loop Discharge 플라즈마의 전자거동과 최적조건에 관한 기초적 연구)

  • Sung, Youl-Moon;Kim, Jong-Kyung;Park, Chung-Hoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.281-287
    • /
    • 2001
  • In order to obtain guidelines for design and operation of a new plasma source by a magnetic neutral loop discharge(NLD), the electron behavior was studied experimentally and numerically. Experimentally, the magnetic field gradient was changed over a wide range, and it was found that there existed an optimum value for efficient plasma production. Analyses of the electron behavior were performed using a model that included effects of a three dimensional electromagnetic field configuration considering the spatial decay of the electric field, and the limitation to the motion of electron caused by the existence of walls and thus electron loss at wall surfaces. These three dimensional factors were found to explain the existence of the optimum magnetic field gradient. It was shown that the L dependence of the plasma production efficiency was firstly decided by the finite decay length of the electric field strength, which was further modified by electron elastic collisions with neutral atoms which drove the electron to walls. The latter effect tends to reduce the optimum value of L.

  • PDF

Calculation of electric field gradient tensor for simple point charge distributions and its application to real systems

  • Choh, Sung-Ho;Shin, Hee-Won;Park, II-Woo;Ju, Heong-Kyu;Kim, Jong-Hyun;Kim, Hae-Jin
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.7 no.1
    • /
    • pp.16-24
    • /
    • 2003
  • Nuclei with the spin quantum number not smaller than unity have not only the nuclear magnetic moment but also the electric quadrupole moment. The quadrupole moment couples with the electric field gradient (EFG) to produce the nuclear quadrupole interaction. It is well known that two independent parameters, i.e. the quadrupole coupling constant (QCC) and the asymmetry parameter ($\eta$) together with the principal axis directions can fully describe the interaction and are very sensitive to the local symmetry and structure of the solid. In order to obtain quantitative estimates of the EFG tensor for various simple ionic configurations surrounding the nucleus under consideration, we employ the simple point charge approximation and apply the calculated results to some real crystals. General agreement is rather satisfactory.

  • PDF

Damping and vibration analysis of viscoelastic curved microbeam reinforced with FG-CNTs resting on viscoelastic medium using strain gradient theory and DQM

  • Allahkarami, Farshid;Nikkhah-Bahrami, Mansour;Saryazdi, Maryam Ghassabzadeh
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.141-155
    • /
    • 2017
  • This paper presents an investigation into the magneto-thermo-mechanical vibration and damping of a viscoelastic functionally graded-carbon nanotubes (FG-CNTs)-reinforced curved microbeam based on Timoshenko beam and strain gradient theories. The structure is surrounded by a viscoelastic medium which is simulated with spring, damper and shear elements. The effective temperature-dependent material properties of the CNTs-reinforced composite beam are obtained using the extended rule of mixture. The structure is assumed to be subjected to a longitudinal magnetic field. The governing equations of motion are derived using Hamilton's principle and solved by employing differential quadrature method (DQM). The effect of various parameter like volume percent and distribution type of CNTs, temperature change, magnetic field, boundary conditions, material length scale parameter, central angle, viscoelastic medium and structural damping on the vibration and damping behaviors of the nanocomposite curved microbeam is examined. The results show that with increasing volume percent of CNTs and considering magnetic field, material length scale parameter and viscoelastic medium, the frequency of the system increases and critically damped situation occurs at higher values of damper constant. In addition, the structure with FGX distribution type of CNTs has the highest stiffness. It is also observed that increasing temperature, structural damping and central angle of curved microbeam decreases the frequency of the system.

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

Magnetic dipole model in an eddy current flow detection for a Nondestructive evaluation

  • Han, S.G.;Kim, J.Y.;Kang, J.H.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 1999
  • A SQUID magnetometer or a SQUID gradiometer can be used to measure the field or gradient distribution respectively. We describe the magnetic dipole model of the eddy current for the nondestructive evaluation. Such a theoretical calculation of the magnetic dipole field produced by a deep flaw in matalic materials can be used for aerospace and transportation fields.

  • PDF

Two-Paralleled PWM Power Amplifiers to Generate Highly Precise Gradient Magnetic Fields in MRI Systems

  • Watanabe, Shuji;Boyagoda, Prasanna;Takano, Hiroshi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.569-574
    • /
    • 1998
  • This paper presents a two-paralleled 4 quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This power amplifier is connected in parallel with the conventional 4-quadrant DC chopper using IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective. DSP-based control systems realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

  • PDF

Expressions of Magnetic vector and Magnetic Gradient Tensor due to an Elliptical Cylinder (타원 기둥에 의한 자력 벡터 및 자력 변화율 텐서 반응식)

  • Hyoungrea Rim;Jooyoung Eom
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.77-83
    • /
    • 2023
  • In this study, the expressions of magnetic vector and magnetic gradient tensor due to an elliptical cylinder were derived. Igneous intrusions and kimberlite structures are often shaped like elliptical cylinders with axial symmetry and different radii in the strike and perpendicular directions. The expressions of magnetic fields due to this elliptical cylinder were derived from the Poisson relation, which includes the direction of magnetization in the gravity gradient tensor. The magnetic gradient tensor due to an elliptical cylinder is derived by differentiating the magnetic fields. This method involves obtaining a total of 10 triple derivative functions acquired by differentiating the gravitational potential of the elliptical cylinder three times in each axis direction. As the order of differentiation and integration can be exchanged, the magnetic gradient tensor was derived by differentiating the gravitational potential of the elliptical cylinder three times in each direction, followed by integration in the depth direction. The remaining double integration was converted to a complex line integral along the closed boundary curve of the elliptical cylinder in the complex plane. The expressions of the magnetic field and magnetic gradient tensor derived from the complex line integral in the complex plane were shown to be perfectly consistent with those of the circular cylinder derived by the Lipschitz-Hankel integral.

Surface Gradient/RF Coil Set for High-Resolution Skin MRI

  • 한재호;김용권;오정민;박상용;오칠환;최보영;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.74-74
    • /
    • 2003
  • 목적: 피부표면에 가까운 고분해능 MR 영상을 얻기 위하여는 Surface RF Coil과 강력한 경사자계를 갖는 Gradient Coil이 필수적으로 요구된다. 본 연구에서는 High-Resolution MR Imaging을 위해 surface RF Coil과 Surface Gradient Coil을 제안하였다. Target Field Method를 사용하여 Gradient Coil의 전력 소모를 최소화하였으며 MR Microscopy가 가능한 50 mm∼100 mm의 해상도가 가능하도록 Coil을 설계하였다.

  • PDF

Background Gradient Correction using Excitation Pulse Profile for Fat and $T_2{^*}$ Quantification in 2D Multi-Slice Liver Imaging (불균일 자장 보정 후처리 기법을 이용한 간 영상에서의 지방 및 $T_2{^*}$ 측정)

  • Nam, Yoon-Ho;Kim, Hahn-Sung;Zho, Sang-Young;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.6-15
    • /
    • 2012
  • Purpose : The objective of this study was to develop background gradient correction method using excitation pulse profile compensation for accurate fat and $T_2{^*}$ quantification in the liver. Materials and Methods: In liver imaging using gradient echo, signal decay induced by linear background gradient is weighted by an excitation pulse profile and therefore hinders accurate quantification of $T_2{^*}$and fat. To correct this, a linear background gradient in the slice-selection direction was estimated from a $B_0$ field map and signal decays were corrected using the excitation pulse profile. Improved estimation of fat fraction and $T_2{^*}$ from the corrected data were demonstrated by phantom and in vivo experiments at 3 Tesla magnetic field. Results: After correction, in the phantom experiments, the estimated $T_2{^*}$ and fat fractions were changed close to that of a well-shimmed condition while, for in vivo experiments, the background gradients were estimated to be up to approximately 120 ${\mu}T/m$ with increased homogeneity in $T_2{^*}$ and fat fractions obtained. Conclusion: The background gradient correction method using excitation pulse profile can reduce the effect of macroscopic field inhomogeneity in signal decay and can be applied for simultaneous fat and iron quantification in 2D gradient echo liver imaging.

Effect of temperature gradient on junction magnetoresistance of magnetic tunnel junction devices

  • No, Seong-Cheol;Park, Min-Gyu;Lee, Yeo-Reum
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.495-497
    • /
    • 2014
  • Combining the quantum transport theory with new field of Spin Caloritronics, we investigate on the influence of thermal gradient on the magneto tunnel junction structure under various circumstances. The results indicate enhancement in performance of spintronic device is possible using thermal energy.

  • PDF