• Title/Summary/Keyword: Magnetic domain wall

Search Result 113, Processing Time 0.027 seconds

Evaluation of 1Cr-1Mo-0.25V Steel Degradation Using Magnetic Barkhausen Noise (Barkhausen noise를 이용한 1Cr-1Mo-0.25V강의 열화도 평가)

  • Lee, Jong-Min;Ahn, Bong-Young;Nahm, Seung-Hoon;Lee, Seung-Seok;Lee, Ouk-Sub;Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1262-1269
    • /
    • 2002
  • It is inevitable to evaluate the life of turbine rotor because the operating periods of power plants need to be extended. For the test, seven kinds of specimens with different degradation levels were prepared by the isothermal heat treatment at $630^{\circ}C$. Magnetic methods utilizing Barkhausen noise coercive force($BN_c$) were applied to detect the degradation caused by thermal aging. Magnetic property of material is related with domain dynamics and that is affected by the microstructure of material. Therefore $BN_c$ is very sensitive to the microstructure change of the material. With the increase of degradation, $BN_c$ was decreased and this phenomenon is considered due to precipitations and grain size. The result was compared with Vickers hardness($H_v$) and coercive force($H_c$) to detect the relative variation, and was related with $H_v$ and YS to estimate the change of the mechanical properties with the degradation.

Effects of Sintering Condition and composition on the Magnetic Properties of Sintered Fe-Si-P (소결조건 및 조성이 Fe-Si-P 소결제의 자기특성에 미치는 영향)

  • 송재성;김기욱
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.684-689
    • /
    • 1991
  • Magnetic properties of sintered Fe-Si-P alloys have been investigated as a function of sintering condition and composition. Sintering was carried in the temperature range from 1100ø C to 1400ø C in vacuum. As the sintering temperature increases, the magnetic properties of specimens were improved mainly due to the easy movement of domain wall because large pores and large grains were formed during the sintering process at high temperature. When sintered at 1400ø C, Fe-2w/o Si-0.5w/o P compact had the best mgnetic properties, but more phosphorus addition degraded magnetic properties. It appears that the degradation was caused by the formation of non-magnetic compounds such as Si P, Fe3P in the compacts with high phosphorus contents.

Recent Developments in Magnetic Measurements: from Technical Method to Physical Knowledge

  • Basso, V.;Fiorillo, F.;Beatrice, C.;Caprile, A.;Kuepferling, M.;Magni, A.;Sasso, C.P.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • We present a few significant advances in methods and concepts of magnetic measurements, aimed both at providing novel routes in the characterization of hard and soft magnetic materials and at improving our basic knowledge of the magnetization process. We discuss, in particular, investigation methods and experimental arrangements that have been developed in recent times for: 1) Hysteresis loop determination in extra-hard magnets by means of Pulsed Field Magnetometry; 2) Broadband observation of domain wall dynamics by highspeed stroboscopical Kerr techniques; 3) Entropy measurements in magnetocaloric materials by calorimetry in magnetic field. While pertaining to somewhat independent fields of investigation, all these measuring techniques have in common a solid approach to the underlying physical phenomenology and have a potential for further developments.

Development of a Magnetic Bead-Based Method for Specific Detection of Enterococcus faecalis Using C-Terminal Domain of ECP3 Phage Endolysin

  • Yoon-Jung Choi;Shukho Kim;Jungmin Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.7
    • /
    • pp.964-972
    • /
    • 2023
  • Bacteriophage endolysins are peptidoglycan hydrolases composed of cell binding domain (CBD) and an enzymatically active domain. A phage endolysin CBD can be used for detecting bacteria owing to its high specificity and sensitivity toward the bacterial cell wall. We aimed to develop a method for detection of Enterococcus faecalis using an endolysin CBD. The gene encoding the CBD of ECP3 phage endolysin was cloned into the Escherichia coli expression vector pET21a. A recombinant protein with a C-terminal 6-His-tag (CBD) was expressed and purified using a His-trap column. CBD was adsorbed onto epoxy magnetic beads (eMBs). The bacterial species specificity and sensitivity of bacterial binding to CBD-eMB complexes were determined using the bacterial colony counting from the magnetic separations after the binding reaction between bacteria and CBD-eMB complexes. E. faecalis could bind to CBD-eMB complexes, but other bacteria (such as Enterococcus faecium, Staphylococcus aureus, Escherichia coli, Acinetobacter baumannii, Streptococcus mutans, and Porphyromonas gingivalis) could not. E. faecalis cells were fixed onto CBD-eMB complexes within 1 h, and >78% of viable E. faecalis cells were recovered. The E. faecalis recovery ratio was not affected by the other bacterial species. The detection limit of the CBD-eMB complex for E. faecalis was >17 CFU/ml. We developed a simple method for the specific detection of E. faecalis using bacteriophage endolysin CBD and MBs. This is the first study to determine that the C-terminal region of ECP3 phage endolysin is a highly specific binding site for E. faecalis among other bacterial species.

Effects of Ag Seed Layer on the Magnetic Properties and the Microstructural Evolution of SmCo/Cr Thin Films (Ag 씨앗층이 SmCo/Cr 박막의 자기적 특성과 미세구조에 미치는 영향)

  • 이성래;고광식;김영근
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.2
    • /
    • pp.63-71
    • /
    • 2001
  • The effects of an Ag seed layer on the magnetic properties and the microstructural evolution of SmCo/Cr thin films deposited on glass substrates were investigated. Coercivity of the films is 2.0 kOe when the thickness of Ag seed layer was 1nm thick, but it increased to 2.7 kOe when the Ag seed layer thickness is 3 nm. The increase of coercivity for film with 3 nm-thick Ag is due to roughness of Cr and grain size of Cr by the Ag microbumps. Ar partial pressure influenced on the formation of Ag microbumps, for example, they were formed at 5 mTorr when Ag thickness was 1 nm. The mechanism of magnetization reversal of the SmCo films changed from domain wall motion to domain rotation as the Ag inserted. This was thought to be due to inhibition of domain wall motion by the reduction of Cr grain size and the increase of roughness.

  • PDF

Effects of Deposition Conditions on Magnetic Properties of SmCo/Cr (스퍼터 제조조건에 따르는 SmCo/Cr 박막의 자기적 특성에 관한 연구)

  • 나태준;고광식;이성래
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.312-320
    • /
    • 1999
  • Effect of deposition conditions on the magnetic properties of SmCo/Cr prepared by a RF magnetron sputtering method was studied. We obtained the maximum coercivity of 3.2 kOe in the sample of Cr(50 nm)/SmCo(40 nm, 50W, 20 mT)/Cr(150 nm, 100 W, 30 mT). The coercivity of the SmCo/Cr depends largely on the roughness of the Cr underlayer and the composition of SmCo. The roughness of the Cr underlayer increased with increasing the Ar pressure and thickness, and promoted the isolation of SmCo grains which resulted in an enhanced coercivity. The composition of the SmCo was changed with RF power and Ar pressure due to the mass difference between Sm and Co and the resputtering phenomena. The maximum coercivity was obtained in the composition of about 20 at.% Sm. The mechanism of magnetization reversal of the present SmCo films changed from domain wall motion to domain rotation as the RF power and the Ar pressure increase. This was though to be due to the defects, such as the roughness of Cr surface, porous column boundaries etc., which inhibit domain wall movement.

  • PDF

Application of a New NDI Method using Magneto-Optical Film for Inspection of Micro-Cracks (미소균열 탐상을 위한 자기광학소자를 이용한 비파괴탐상법의 제안과 적용)

  • Lee, Hyoung-No;Park, Han-Ju;Shoji, Tetsuo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.197-203
    • /
    • 2001
  • Micro-defects induced by design and production failure or working environments are known as the cause of SCC(Stress Corrosion Cracking) in aged structures. Therefore, the evaluation of structural integrity based on micro-cracks is required not only a manufacturing step but also in-service term. So we introduce a new nondestructive inspection method using the magneto-optical film to detect micro-cracks. The method has some advantage such as high testing speed, real time data acquistion and the possibility of remote sensing by using of a magneto-optical film that takes advantage of the change of magnetic domains and domain walls. This paper introduces the concept of the new nondestructive inspection method using the magneto-optical film, also proves the possibility of this method as a remote testing system under oscillating load considering application on real fields by applying the method to four types of specimens.

  • PDF

Growth and Magnetic Characteristics of MnSb Epilayer by Hot-Wall Epitaxy (Hot-Wall Epitaxy에 의한 MnSb 박막의 성장과 자기적 특성)

  • Lee, Man-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.22 no.2
    • /
    • pp.151-162
    • /
    • 2004
  • MnSb layers were grown on GaAs(100), (111)A and (111)B substrates by hot wall epitaxy under various growth conditions. Growth condition dependence of structural properties of the layers was examined. The growth direction and structural properties of MnSb/GaAs(100) depend on Sb source and substrate temperatures. The smooth MnSb(10.1)/GaAs(100) interface was obtained under the appropriate growth condition. On the other hand, MnSb(00.1) layers were grown on GaAs(111) substrates. The quality of the layers on (111)B was superior to that on GaAs(111)A, but degraded as in increasing Sb source temperature during the growth. The $Mn_2Sb$ domain was generated in the layers grown under conditions of low Sb source temperature and high substrate temperature on GaAs(111) substrates.

  • PDF