• Title/Summary/Keyword: Magnetic assembly

Search Result 139, Processing Time 0.027 seconds

Three-Dimensional Self-Assembled Micro-Array Using Magnetic Force Interaction

  • Park, Yong-Sung;Kwon, Young-Soo;Eiichi Tamiya;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권5호
    • /
    • pp.182-188
    • /
    • 2003
  • We have demonstrated a fluidic technique for self-assembly of microfabricated parts onto substrate using patterned shapes of magnetic force self-assembled monolayers (SAMs). The metal particles and the array were fabricated using the micromachining technique. The metal particles were in a multilayer structure (Au, Ti, and Ni). Sidewalls of patterned Ni dots on the array were covered by thick negative photoresist (SU-8), and the array was magnetized. The array and the particles were mixed in buffer solution, and were arranged by magnetic force interaction. Binding direction of the metal particle onto Ni dots was controlled by multilayer structure and direction of magnetization. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost even with the Au surface on top. The particles were successfully arranged on the array.

Fabrication and Manipulation of Gold 1D Chain Assemblies Using Magnetically Controllable Gold Nanoparticles

  • Kim, Lily Nari;Kim, Eun-Geun;Kim, Junhoi;Choi, Sung-Eun;Park, Wook;Kwon, Sunghoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3735-3739
    • /
    • 2012
  • We have developed magnetically controllable gold nanoparticles by synthesizing superparamagnetic $Fe_3O_4$ core/gold shell nanoparticles. The core/shell particles have the capability of forming gold 1D chains in the presence of an external magnetic field. Here we demonstrate dynamic and reversible self-assembly of the gold 1D chain structures in an aqueous solution without any templates or physical or chemical attachment. The spatial configuration of gold chains can be arbitrarily manipulated by controlling the direction of a magnetic field. This technique can provide arbitrary manipulation of gold 1D chains for fabrication purpose. To demonstrate this capability, we present a technique for immobilization of the gold particle chains on a glass substrate.

Characteristics of Magnetic Resonance-Based Attenuation Correction Map on Phantom Study in Positron Emission Tomography/Magnetic Resonance Imaging System

  • Hong, Cheolpyo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.189-193
    • /
    • 2020
  • An MR-based attenuation correction (MRAC) map plays an important role in quantitative positron emission tomography (PET) image evaluation in PET/magnetic resonance imaging (MRI) systems. However, the MRAC map is affected by the magnetic field inhomogeneity of MRIs. This study aims to evaluate the characteristics of MRAC maps of physical phantoms on PET/MRI images. Phantom measurements were performed using the Siemens Biograph mMR. The modular type physical phantoms that provide assembly versatility for phantom construction were scanned in a four-channel Body Matrix coil. The MRAC map was generated using the two-point Dixon-based segmentation method for whole-body imaging. The modular phantoms were scanned in compact and non-compact assembly configurations. In addition, the phantoms were scanned repeatedly to generate MRAC maps. The acquired MRAC maps show differently assigned values for void areas. An incorrect assignment of a void area was shown on a locally compact space between phantoms. The assigned MRAC values were distorted using a wide field-of-view (FOV). The MRAC values also differed after repeated scans. However, the erroneous MRAC values appeared outside of phantom, except for a large FOV. The MRAC map of the phantom was affected by phantom configuration and the number of scans. A quantitative study using a phantom in a PET/MRI system should be performed after evaluation of the MRAC map characteristics.

The Creation of a Strong Magnetic Field by Means of Large Magnetic Blocks from NdFeB Magnets in Opposing Linear Halbach Arrays

  • Zezulka, Vaclav;Straka, Pavel
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.364-373
    • /
    • 2016
  • The article presents the results and findings obtained through the assembly of opposing linear Halbach arrays from two magnet layers using large magnetic blocks from permanent NdFeB magnets, especially concerning the distribution of magnetic induction in an air gap. The use of these large blocks has led to a significant expansion of the area of magnetic field with a substantially higher value of magnetic induction in comparison with similar linear Halbach arrays composed of small magnets. The paper also discusses the determined dependences of magnetic induction on the parameters of the x, y, z coordinate system and indicates the possibilities of achieving an even stronger magnetic field in a larger volume of an air gap for application for instance in equipment for magnetic separation of raw materials, in instrument technologies and in other areas.

고속회전용 자기베어링 시스템의 Eddy Current 효과에 관한 연구

  • 경진호;노승국;박종권
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 1997
  • Eddy current effect in a high speed rotor suspended by a mangnetic bearing is invstigated using electromagnetic field analysis technique. The non-zero conductivity model of a laminated rotor sleeve is proposed to concern electrical shorting of laminates due to rub, handling or press fit assembly,et al. As the rotating speed increase, the distibution of magnetic flux line is changed and the magnetic forces decrease remarkably. ANSYS Magnetics (version 5.3) is used for the magnetic field analysis.

자성유체 댐퍼를 이용한 광픽업 액츄에이터의 동특성 개선 (Improvement of dynamic characteristics of optical pick-up actuator using ferrofluidic damper)

  • 송병륜;신경식;김진기;남도선;성평용;이주형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.496-503
    • /
    • 2001
  • The suspension of the optical pickup actuator is damped by the presence of silicone rubber damper bond at its termination. In spite of the presence of it, the actuator still exhibits a strong mechanical resonance which affects its settling time and vibrational characteristics. This resonance can cause errors in reading information from the disk, particularly in high speed CD-ROM and DVD-ROM drives. Ferrofluids are stable colloidal suspensions of sub-micron sized magnetic particles in a carrier liquid. In the actuator design, ferrofluid is applied to the surface of the magnets until the quantity is sufficient to maintain intimate contact with the bobbin/carrier assembly. The fluid is retained in the magnetic field and its viscosity provides the desired mechanical damping to the moving assembly, improving the actuators settling time and vibrational characteristics. Access time is also improved, particularly on warped or eccentric discs.

  • PDF

자기력에 의한 신규 바이오칩의 개발 (Development of New Biochip Using Magnetic Force)

  • 최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.105-108
    • /
    • 2006
  • This paper describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and random fluidic self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

자기력에 의한 단백질칩 (Protein Chip Using Magnetic Force)

  • 최용성;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.386-387
    • /
    • 2006
  • This research describes a new constructing method of multifunctional biosensor using many kinds of biomaterials. A metal particle and an array was fabricated by photolithographic. Biomaterials were immobilized on the metal particle. The array and the particles were mixed in a buffer solution, and were arranged by magnetic force interaction and self-assembly. A quarter of total Ni dots were covered by the particles. The binding direction of the particles was controllable, and condition of particles was almost with Au surface on top. The particles were successfully arranged on the array. The biomaterial activities were detected by chemiluminescence and electrochemical methods.

  • PDF

조립오차의 광학식 측정에 의한 VCR HEAD 조정 SYSTEM (Adjustment System by Optical Measurements of Assembly Tolerancies of VCR HEAD)

  • 윤병한;윤종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.849-851
    • /
    • 1995
  • Magnetic heads on vcr drum are adjusted for protrusion, rotational angle, setting angle between two symmetrically positioned heads and height difference. Developed adjustment system covered assembly spec., namely ${\pm}2{\mu}m$ and ${\pm}30{\mu}m$ in rotational angle by using the image processing to determine head positions and S/W algorithm to compensate mechanical errors.

  • PDF