• 제목/요약/키워드: Magnetic array

검색결과 285건 처리시간 0.07초

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

자율주행차량과 로봇의 안내를 위한 자계위치인식시스템 (Magnetic Position Sensing System for Autonomous Vehicle and Robot Guidance)

  • 정영윤;김근모;유영재
    • 한국지능시스템학회논문지
    • /
    • 제17권2호
    • /
    • pp.214-219
    • /
    • 2007
  • 본 논문은 자율주행차량과 로봇의 안내를 위한 새로운 자계위치인식방법을 제안한다. 차량 및 로봇이 자율주행을 하기 위해서는 이동경로상의 현재 위치를 인식하는 것이 기본적으로 요구된다. 자계기반 자율주행차량과 로봇은 자성체로부허 발생되는 자계를 계측하여 위치정보를 검출한다. 이러한 자계위치인식시스템에서 지구자계는 기본적인 왜란으로 작용한다. 본 논문에서는 지구자계의 영향을 제거하기 위해 다수의 1축 자계센서 열을 구성하였으며, 자계센서 출력의 선형동작영역을 이용하여 정밀한 위치인식시스템을 개발하였다. 제안하는 방법이 자율주행차랑과 로봇의 안내를 위해 사용 가능함을 실험을 통하여 검증하였다.

고정밀 회전 및 축방향 이송을 위한 신개념 원통형 자기부상 스테이지 (Novel Cylindrical Magnetic Levitation Stage for Rotation as well as Translation along Axles with High Precisions)

  • 전정우;;이창린;정연호;김종문;오현석;김성신
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1828-1835
    • /
    • 2012
  • In this paper, a conceptual design and a detailed design of novel cylindrical magnetic levitation stage is introduced. This is came from planar-typed magnetic levitation stage. The proposed stage is composed of cylinder-typed permanent magnet array and semi-cylinder-typed 3 phase winding module. When a proper current is induced at winding module, a magnetic levitation force between the permanent magnet array and winding module is generated. The proposed stage can precisely move the cylinder to rotations and translations as well as levitations with the magnetic levitation force. This advantage is useful to make a nano patterning on the surface of cylindrical specimen by using electron beam lithography under vacuum. Two methods are used to calculate required magnetic levitation forces. The one is 2D FEM analysis, the other is mathematical modeling. This paper shown that results of two methods are similar. An assistant plate is introduced to reduce required currents of winding module for levitations in vacuum. The mathematical model of cylindrical magnetic levitation stage is used for dynamic simulation of magnetic levitations. A lead-lag compensator is used for control of the model. Simulation results shown that the detail designed model of the cylindrical magnetic levitation stage with the assistant plate can be controlled very well.

체적 지향형 호흡정지 자기공명 조영술의 가속화에 대한 32채널 코일 어레이의 효용성 (Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA)

  • 이현열;서진석;박재석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.137-145
    • /
    • 2009
  • 목적: 각각 12개와 32개 요소 표면 코일 어레이를 사용한 가속율이 매우 큰 관상동맥 자기 공명 혈관조영술을 병렬 영상 기법에 적용하고 결과를 비교한다. 방법: 5명의 건강한 지원자에 대하여 1.5T 전신 자기공명영상장치에서 각각 12개와 32개 요소 표면 코일 어레이를 사용한 steady state free precession 자기공명 혈관조영술이 수행되었다. 각 지원자의 좌전하방관상동맥과 우관상동맥을 영상하여 데이터를 얻었다. 데이터는 병렬 영상을 위하여 1에서 6에 이르는 감소율로 부분 추출되었다. 양 코일 어레이 각각에 대하여 지형 인자의 평균, 극대, 그리고 인공물정도가 계산되었다. 결과: 모든 감소율에 있어서, 32개 요소 어레이가 12개 요소 어레이에 비하여 지형인자의 평균과 극대, 그리고 인공물정도가 상당히 줄어들었다 (P << 0.1). 지형인자의 평균은 관상동맥의 영상 방향에 민감한 반면, 지형인자 극대치와 인공물정도는 영상 방향에 독립적이었다. 결론: 가속율이 매우 큰 관상동맥 자기공명 혈관조영술의 병렬 영상 적용에 있어 32개 요소 표면 코일 어레이를 사용함은 인공물과 잡음을 상당히 억제시킨다. 32개 요소 표면 코일 어레이를 사용하여 가속율을 증가시키는 것은 공간 해상도를 향상시키거나 3D관상동맥 자기공명 혈관조영술에 있어서 체적 범위를 증가시킬 수 있는 가능성을 제공한다.

  • PDF

자기장 지도를 이용한 위치 추정 (Position Estimation Using Magnetic Field Map)

  • 김한솔;문우성;서우진;백광렬
    • 제어로봇시스템학회논문지
    • /
    • 제19권4호
    • /
    • pp.290-298
    • /
    • 2013
  • Geomagnetic is refracted by building's wall and pillar. Therefore refracted geomagnetic is able to be used as feature point. In a specific space, a mobile device that is equipped with magnetic sensor array measures 3-axis magnetic field for each point. Magnetic field map is acquired by collecting the every sample point in the magnetic field. The measured magnetic field must be calibrated, because each magnetic sensor has a distortion. For this reason, sensor distortion model and sensor calibration method are proposed in this paper. Magnetic field that is measured by mobile device matches magnetic field map. Result of the matching is used for position estimation. This paper implements hardware system for position estimation method using magnetic field map.

곡면 자기연마에서의 자기력 형성과 가공특성에 관한 연구 (Evaluations of Magnetic Abrasive Polishing and Distribution of Magnetic Flux Density on the Curvature of Non-Ferrous Material)

  • 김상오;곽재섭
    • 대한기계학회논문집A
    • /
    • 제36권3호
    • /
    • pp.259-264
    • /
    • 2012
  • 비자성체의 자유곡면 자기연마 공정에서 자기력 세기의 향상은 매우 중요하다. 비자성체 자유곡면의 표면에 발생하는 자기력의 세기에 따라 자기연마 입자가 가지는 수직 절삭력이 변화하기 때문이다. 이러한 자기력 향상을 위하여 전자석 배열 테이블이 적용된 제 2세대 자기연마공정이 비자성체의 자유곡면 자기연마에 적용된다. 본 연구에서는 이러한 제 2세대 자기연마공정에서 전자석 배열 테이블에 발생하는 자기력 세기 향상을 위한 극성배열 방법을 제시하고 이를 알루미늄합금의 곡률 자기연마에 적용하였다. 그 결과 볼록 및 오목 형상에서 각각 S-N-S와 S-N-N-N-S 극성 배열에서 가장 높은 표면거칠기의 향상을 확인하였다. 또한 상승 가공경로에서 상대적으로 높은 표면거칠기 향상을 나타내었다.

초고자장 병렬송신 MRI에서의 머리위치에 따른 RF 필드의 불균일도 비교 (RF Field Inhomogeneity Changes Depending on the Head Position in Parallel-Transmission Ultra-High-Field MRI)

  • 오종석;현정호;서증훈;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.486-488
    • /
    • 2008
  • 300 MHz가 넘는 초고자장 MRI에서는 송신 또는 수신 RF Magnetic Field 의 불균일도가 심해져서 이를 개선하기 위한 많은 방법들이 제안되고 있다. 그 중 가장 대표적인 방법은 $4{\sim}32$ 채널의 Transmit Array의 각 채널에 인가되는 전압과 위상을 변화시켜 RF Magnetic Field의 불균일도를 개선하는 방법이다. 본 논문에서는 Transmit Array 내부에서 머리위치의 변화에 따라 RF Magnetic Field ($B_1$ Field) 의 불균일도가 많이 변화하며 이에 따라 RF 송신용 전압과 위상의 Pattern을 새로 최적화 해야 함을 확인하였다. 또한 RF field Mapping을 하기 위해서 Composite RF Sequence를 사용한 Rapid Sequence의 사용과 채널 전압과 위상을 최적화하기 위해서 일반적인 Iterative 방식보다 간편하고 빠른 Target Method를 제안하였다. Driving 패턴의 최적화는 Complex 행렬식을 사용했으며 RF Magnetic Field ($B_1$ Field) 분포는 FDTD 방식으로 계산하였다.

  • PDF