• Title/Summary/Keyword: Magnetic air-gap

Search Result 321, Processing Time 0.029 seconds

Acceleration Feedforward Control in Active Magnetic Bearing System Subject to Base Motion by Filtered-x LMS Algorithm (베이스 가진을 받는 능동자기베어링 시스템에서 Filtered-x LMS 알고리듬을 이용한 가속도 앞먹임 제어)

  • Kang, Min-Sig
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1712-1719
    • /
    • 2003
  • This paper concerns on application of active magnetic bearing(AMB) system to levitate the elevation axis of an electro-optical sight mounted on moving vehicles. In such a system, it is desirable to retain the elevation axis within the predetermined air-gap while the vehicle is moving. An optimal base acceleration feedforward control is proposed to reduce the base motion response. In the consideration of the uncertainty of the system model, a filtered-x least-mean-square(FXLMS) algorithm is used to estimate the frequency response function of the feedforward control which cancels base motions. The frequency response function is fitted to an optimal feedforward control. Experimental results demonstrate that the proposed control reduces the air-gap deviation to 27.7% that by feedback control alone.

The Design of a Device for the Generation of a Strong Magnetic Field in an Air Gap using Permanent Magnets

  • Zezulka, Vaclav;Straka, Pavel
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.250-256
    • /
    • 2017
  • The article presents the principle of a relatively small device that makes it possible to generate a strong magnetic field in an air gap without electrical energy consumption. It describes the implemented design of this device, the method of the assembly of opposing linear arrays from two NdFeB magnet layers, its advantages, the possible ways of increasing the parameters further and its application in various areas.

Control of Conductive Plate Through Varying the Open Area Size of the Partially, Magnetically Isolated Electrodyamic Wheel (부분 차폐된 동전기 휠의 개방 영역 크기 조절을 통한 전도성 평판의 제어)

  • Jung, Kwang-Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.230-236
    • /
    • 2012
  • Shielding the air-gap magnetic field of the electrodynamic wheel below a conductive plate and opening the shielding plate partially, a thrust force and a normal force generate on the conductive plate at the open area. But, as only the variable controlling both forces is a rotating speed of the electrodynamic wheel, it is very difficult to control the forces independently by the speed. So, we discuss a novel method controlling the forces effectively through manipulating a size of the open area. The independent control is made possible by virtue of the feature that the relative ratio between both forces is irrelevant to an air-gap length and determined uniquely for a specific rotating speed of the wheel. Therefore, the rotating speed and the size of open area become new control variables. The feasibility of the method is verified experimentally. Specially, the controllable magnetic forces are used in a noncontact conveyance of the conductive plate.

Unbalanced Magnetic Forces in Rotational Unsymmetrical Transverse Flux Machine

  • Baserrah, Salwa;Rixen, Keno;Orlik, Bernd
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.184-192
    • /
    • 2012
  • The torque and unbalanced magnetic forces in permanent magnet machines are resultants of the tangential, axial and normal magnetic forces, respectively. Those are in general influenced by pole-teeth-winding configuration. A study of the torque and unbalanced magnetic forces of a small flux concentrating permanent magnet transverse flux machine (FCPM-TFM) in segmented compact structure is presented in this paper. By using FLUX3D software from Cedrat, Maxwell stress tensor has been solved. Finite element (FE-) magneto static study followed by transient analysis has been conducted to investigate the influence of unsymmetrical winding pattern, in respect to the rotor, on the performance of the FCPM-TFM. Calculating the magnetic field components in the air gap has required an introduction of a 2D grid in the middle of the air gap, whereby good estimations of the forces are obtained. In this machine, the axial magnetic forces reveal relatively higher amplitudes compared to the normal forces. Practical results of a prototype motor are demonstrated through the analysis.

Characteristic Analysis of Axial-gap Motor using Magnetic Charge (Magnetic charge를 이용한 Axial-gap 전동기의 특성해석)

  • Lee, Sang-Ho;Kim, Do-Jin;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.997-998
    • /
    • 2007
  • This paper deals with analytical solution concerning the image method using the magnetic charge instead of 3D FEA(finite element analysis) in the slotless single air-gap motor. The theory of analytical method and the design procedures are introduced. The reliability and validity of proposed analytical solution are verified through the comparison with the results of commercial 3D FE software. In addition, calculation time between proposed analytical solution and 3D FEA is compared. Finally, characteristics, such as Back-EMF and phase resistance, between calculated and experimental results are compared. From the verification with 3D FEA and experimental results, it is proved that presented analytical method provided very effective and precise results.

  • PDF

AC-DC Converter using the PFC Inductor and LLC Resonant Transformer with an Integrated Magnetic Core (하나의 코아로 집적화된 PFC 인덕터와 LLC 공진변압기 적용 AC-DC 컨버터)

  • Noh, Young-Jae;Kang, Cheol-Ha;Saran, Meas;Kim, Eun-Soo;Won, Jong-Seob;Kim, Dong-Hee;Lee, Young-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.262-272
    • /
    • 2015
  • An integrated two-in-one transformer applicable to PSUs for a 120 W LED TV is proposed. This transformer comprises a PFC inductor and an LLC transformer placed and integrated on an E-I-E type magnetic core. Performance is evaluated by observing the coupling coefficients of the proposed two-in-one transformer under various air gap topologies. Among the topologies studied, an integrated transformer with centered air gap shows stable operational characteristics with a minimized mutual coupling (interference). Furthermore, applicability of the proposed integrated transformer to PSUs for a 120 W LED TV is studied from the viewpoint of integrating different magnetic components into one core, resulting to low weight, low cost, and high power density.

Contact-less Conveyance of Conductive Plate by Controlling Permalloy Sheet for Magnetic Shield of Air-gap Magnetic Field from Magnet Wheels (마그네트 휠의 공극 자기장 차폐판 조절에 의한 도전성 평판의 비접촉 반송)

  • Jung, Kwang-Suk;Shim, Ki-Bon;Lee, Sang-Heon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.109-116
    • /
    • 2010
  • The magnet wheel which generates on its interfacing conductive part a repulsive force and a traction torque by rotation of permanent magnets is used to manipulate the conductive plate without mechanical contact. Here, the air-gap magnetic field of the magnet wheel is shielded partially to convert the traction torque into a linear thrust force. Although a magnitude of the thrust force is constant under the fixed open region, we can change the direction of force by varying a position of the shield sheet. So, the spatial position of conductive plate is controlled by not the force magnitude from each magnet wheel but the open position of shield sheet. This paper discusses non-contact conveyance system of the conductive plate using electromagnetic forces from multiple magnet wheels.

A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS (치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구)

  • Lim, Yong-Sik;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

Nonlinear Vibration Analysis of Cantilever Beam Subject to Electromagnetic Force (전자력을 받는 외팔보의 비선형진동)

  • 최연선;서경석;우영주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.283-288
    • /
    • 2001
  • The nonlinear vibration of a cantilever beam due to electromagnetic force is studied. The dynamic responses of the beam show various phenomena with the variation of the system parameters, such as jump phenomenon, multiple solutions and the change of the natural frequency. The nonlinear stiffness due to electromagnetic forces which depends on air gap size is measured experimentally. This system was modeled by a single degree of freedom nonlinear dynamic system and solved numerically for the system parameters. The numerical results show good agreements with the experimental observations, which demonstrates the nonlinearity of magnetic force.

  • PDF