• Title/Summary/Keyword: Magnetic Stimulation

Search Result 236, Processing Time 0.025 seconds

Magnetic Nerve Stimulation Coils with Magnetic Mirror Effect (자계 거울 효과를 이용한 신경 자극 코일)

  • 한병희;김기왕;김재곤;박태석;이수열;조민형;양종수;김정회
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.287-293
    • /
    • 2002
  • For non-contact nerve stimulations using time varying magnetic field, high amplitude current pulses have to be applied to a magnetic nerve stimulation coil. To increase the magnetic stimulation frequency we have to increase both power supply capacity and cooling capacity of the magnetic nerve stimulator. To alleviate these problems. we propose a new magnetic nerve stimulation coil design methods. Utilizing magnetic mirror effect of a ferro-magnetic plate attached to a magnetic stimulation coil. we have improved efficiency of the stimulation coil. We have analyzed magnetic mirror effect for various kinds of stimulation coils using the finite element method, and we present experimental results obtained with several kinds of stimulation coils.

Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment (요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정)

  • Han, Byung-Hee;Choi, Kyung-Moo;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.

The development of a high efficient transcranial magnetic stimulation adopted real time-charging-discharging circuit

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we have been proposed the new type of a transcranial magnetic stimulation adopted a variable voltage capacitor with Cockcroft-Walton circuit and constant-frequency current resonant half-bridge inverter. This a transcranial magnetic stimulation has some merits compared with the conventional one. First, it doesn't require the high voltage transformer. And second, it has less switching losses, compact size and capability in adjusting the transcranial magnetic stimulation output energy precisely. In this paper, we have performed the output characteristics of a transcranial magnetic stimulation system which is well known as magnetic stimulation. The tested results are described as a function of pulse repetition rate and switching numbers of the half-bridge inverter.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

Changes in Poly ADP Ribose Polymerase Immune Response Cells of Cerebral Ischaemia Induced Rat by Transcranial Magnetic Stimulation of Alternating Current Approach

  • Koo, Hyun-Mo;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.357-364
    • /
    • 2014
  • This study examined effect of a transcranial magnetic stimulation device with a commercial-frequency approach on the neuronal cell death caused ischemia. For a simple transcranial magnetic stimulation device, the experiment was conducted on an ischemia induced rat by transcranial magnetic stimulation of a commercial-frequency approach, controlling the firing angle using a Triac power device. The transcranial magnetic stimulation device was controlled at a voltage of 220 V 60 Hz and the trigger of the Triac gate was varied from $45^{\circ}$ up to $135^{\circ}$. Cerebral ischemia was caused by ligating the common carotid artery of male SD rats and reperfusion was performed again to blood after 5 minutes. Protein Expression was examined by Western blotting and the immune response cells reacting to the antibodies of Poly ADP ribose polymerase in the cerebral nerve cells. As a result, for the immune response cells of Poly ADP ribose polymerase related to necrosis, the transcranial magnetic stimulation device suppressed necrosis and had a protective effect on nerve cells. The effect was greatest within 12 hours after ischemia. Therefore, it is believed that in the case of brain damage caused by ischemia, the function of brain cells can be restored and the impairment can be improved by the application of transcranial magnetic stimulation.

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

The Characteristics on the Change of Cerebral Cortex using Alternating Current Power Application for Transcranial Magnetic Stimulation

  • Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.197-204
    • /
    • 2014
  • A transcranial magnetic stimulation device is a complicated appliance that employs a switching power device designed for discharging and charging a capacitor to more than 1 kV. For a simple transcranial magnetic stimulation device, this study used commercial power and controlled the firing angle using a Triac power device. AC 220V 60 Hz, the power device was used directly on the tanscranial magnetic stimulation device. The power supply device does not require a current limiting resistance in the rectifying device, energy storage capacitor or discharge circuit. To control the output power of the tanscranial magnetic stimulation device, the pulse repetition rate was regulated at 60 Hz. The change trigger of the Triac gate could be varied from $45^{\circ}$ to $135^{\circ}$. The AVR 182 (Zero Cross Detector) Chip and AVR one chip microprocessor could control the gate signal of the Triac precisely. The stimulation frequency of 50 Hz could be implemented when the initial charging voltage Vi was 1,000 V. The amplitude, pulse duration, frequency stimulation, train duration and power consumption was 0.1-2.2T, $250{\sim}300{\mu}s$, 0.1-60 Hz, 1-100 Sec and < 1 kW, respectively. Based on the results of this study, TMS can be an effective method of treating dysfunction and improving function of brain cells in brain damage caused by ischemia.

The Effect of Direct Functional Magnetic Stimulation of the Lesion on Functional Motor Recovery in Spinal Cord Injured Rat (척수손상 흰 쥐의 운동기능 회복에 미치는 손상부위 직접자극을 통한 기능적 자기자극치료 효과)

  • Cho, Yun-Woo;Kim, Su-Jeong;Park, Hea-Woon;Seo, Jeong-Min;Hwang, Se-Jin;Jang, Sung-Ho;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the effect of direct functional magnetic stimulation (FMS) of affected spinal cord on motor recovery following spinal cord injury in rats. Methods: After a contusion injury at the spinal level T9 using an NYU Impactor, functional magnetic stimulation was delivered by a magnetic stimulator through a round prototype coil (7 cm in diameter). Stimulation parameters were set as follows: repetition rate = 50 Hz (stimulus intensity 100% = 0.18 T), stimulation time = 20 min. Functional magnetic stimulation was administered twice a day, 5 days per week for 8 weeks starting 4 days after spinal cord injury. Functional magnetic stimulationwas delivered directly to the affected spinal cord. Outcomes of locomotor performance were assessed by the Basso Beattie Bresnahan (BBB) locomotor rating scale and by an inclined plane test weekly for 8 weeks. Results: In the BBB test, hindlimb motor function in the Functional magnetic stimulation group improved significantly more compared to the control group at 3, 4, 6, 7, and 8 weeks (p<0.05). In the inclined plane test, the angle of the plane in the functional magnetic stimulation group increased significantly more compared to the control group at 4, 5, 7, and 8 weeks (p<0.05). Conclusion: Our results demonstrate that direct Functional magnetic stimulation of the lesional site may have beneficial effects on motor improvement after spinal cord injury.

Mouse Somatosensory Cortex Stimulation Using Pulse Modulated Transcranial Magnetic Stimulation (구형파 변조된 경두개 자기자극을 이용한 쥐의 감각피질 자극실험)

  • Sun, Sukkyu;Seo, Taeyoon;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.482-485
    • /
    • 2016
  • In this work, a transcranial magnetic stimulation(TMS) experiment on animals is performed to stimulate the brain cortex of the mouse using modulated signals. The proposed TMS system is composed of the inverter, transformer, capacitor, variable inductor, and stimulation coil to generate 1.5 mT magnetic field in the brain cortex of the mouse. The stimulation signal is modulated to square wave where the carrier frequency is swept from 85 to 91 kHz to investigate the stimulation effect. The experimental result shows that when the carrier frequency of the stimulation signal is lower than 89 kHz, the reaction of the mouse does not change while the stimulation signal which has the carrier frequency higher than 89 kHz results in decreasing the threshold of the stimulus for the pressure.

TreatmentWD Pulse Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Jun-Il;Lee, Sun-Min;Bo, Gak-Hwang;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.36-41
    • /
    • 2012
  • The transcranial magnetic stimulation recharges the energy storing condenser, and sends the stored energy in the condenser to the pulse shaping circuit, which then delivers it to the stimulating coil. The previous types of transcranial magnetic stimulation required a booster transformer, secondary rectifier for high voltages and a condenser for smooth type. The energy storing condenser is recharged by switching the high-voltage direct current power. Loss occurs due to the resistance in the recharging circuit, and the single-pulse output energy in the transcranial magnetic stimulation can be changed because the recharging voltage cannot be adjusted. In this study a booster transformer, which decreases the volume and weight, was not used. Instead, a current resonance inverter was applied to cut down the switching loss. A transcranial magnetic stimulation, which can simultaneously alter the recharging voltage and pulse repeats, was used to examine the output characteristics.